This standard specifies the technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of glass fiber fixed-weave casing. This standard is applicable to fixed-weave casing made of alkali-free glass fiber braided tube that still maintains a round cross-section after heat treatment. JB/T 7091-1993 Glass fiber fixed-weave casing JB/T7091-1993 standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standards of the People's Republic of China JB/T7091~7100—93 Electrical Material Standards (3) Published in 1993—1008www.bzxz.net Implemented in 1994—01-01 Published by the Ministry of Machinery Industry of the People's Republic of China JB/T 709193 JB/T 7092-93 JB/T 709393 JB/T 709493 JB/T709593 JB/T709693 JB/T 7097—93 JB/T7098—93 JB/T7099—93 JB/T7100—93 Glass fiber fixed sleeve Methods for measuring basic properties of silver-based composite electrical contacts..Silicone resin glass fiber self-extinguishing tube… Modified polyester impregnation varnish… Imine epoxy impregnation varnish Technical conditions for copper bismuth cerium contact materials.. Technical conditions for copper bismuth aluminum contact materials Technical conditions for copper chromium contact materials.. Plastic mica board Flexible Soft mica board. (4) (10) (13) *(16) (22) (25) (28) (31) Subject content and scope of application Machinery Industry Standard of the People's Republic of China Glass fiber fixed pattern casing JB/T7091-93 This standard specifies the technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of glass fiber fixed pattern casing (hereinafter referred to as fixed pattern casing). This standard applies to corrugated tubes made of alkali-free glass fiber braided tubes that still maintain a round cross-section after heat treatment, and reference standards GB7113 GB7114 3 Technical requirements 3.1 Appearance General requirements for electrical insulating paint tubes Test methods for electrical insulating paint tubes Corrugated tubes should be round, have neat ends, and be natural in color. 3.2 Dimensions 3.2.1 Length The length is 1000 mm, and other lengths are agreed upon by both the supplier and the buyer. 3.2.2 The inner diameter, wall thickness and deviation should comply with the provisions of Table 1. Table 1 1.0#1.5,2.0,2.5;3.0;3.5;4.0 5.0;6.0;7.0;8.0;9.0;10.0 3.3 Performance requirements Performance requirements shall comply with the requirements of Table 2. Test method Heat loss Tensile strength Shear characteristics Sample treatment conditions and test environment conditions ≥>90 After the fixed grain section is cut by scissors, the cut is flat and there is no fiber unraveling phenomenon. According to the provisions of Chapter 1 and Chapter 2 of GB7114. Approved by the Ministry of Machinery Industry on October 8, 1993 Implemented on January 1, 1994 4.2 Appearance Evaluated by visual inspection. 4.3 Length Measure with a ruler or steel tape with a scale of 1mm. 4.4 Inner diameter According to the provisions of Chapter 3 of GB7114. 4.5 Wall thickness According to the provisions of Chapter 4 of GB7114. 4.6 Weight loss on heat 4.6.1 Number and quality of samples JB/T7091-93 Three samples, each of which should be long enough to provide a mass of 5±1g. 4.6.2 Procedure The sample is treated at 105±2℃ for 1h, then cooled to room temperature in a desiccator, and the sample is weighed to an accuracy of 0.0002g. Then it is heated in a high-temperature furnace at 600±10℃ for 6075min, cooled to room temperature in a desiccator, and then the sample is weighed. 4.6.3 Results The percentage of thermal weight loss is calculated as follows: The thermal weight loss (%) = m = m2 × 100 Where: mi - mass of the sample before high temperature heating, g; m2 - mass of the sample after high temperature heating, g. Take the median of the three calculated values as the test result, take two significant figures, and report the other two values. 4.7 Tensile strength Except as specified below, the rest shall be carried out in accordance with the provisions of Chapter 12 of GB7114. 4.7.1 The tensile speed shall be 25±5mm/min. 4.7.2 The cross-sectional area shall be calculated as the product of twice the wall thickness measured in 4.5 and the width of the flat belt prepared below: First, use a tensile force of about 10% of the breaking stress to pull the corrugated tube into a shoulder flat belt shape, and then place it between flat plates and slightly pressurize it to form a belt. It is required that the edge of one of the flat plates is marked with a scale to measure the width of the belt. 4.8 Cutting characteristics Take 5 sections of the sample (do not rub them), lay them flat on the table, cut the fixed-corrugated pipe with sharp scissors, and observe the cross section at the cut. 5 Inspection rules 5.1 Products produced continuously for 24 hours on one equipment with the same raw materials and processes are considered a batch. Each batch of products must undergo factory inspection. The factory inspection items are the second and third items in Table 2 of Article 3.1, Article 3.2 and Article 3.3 of this standard. 5.2 Type inspection items are all items of the technical requirements in Chapter 3 of this standard, which shall be carried out at least once every three months. When the raw materials or processes are changed, type inspection shall also be carried out. 5.3 Others shall comply with the provisions of Chapter 4 of GB7113. 6 Marking, packaging, transportation, storage 6.1 The storage period is 6 months. 6.2 Others shall comply with the provisions of Chapter 5 and Chapter 6 of GB7113. 2 Additional Notes: JB/T709193 This standard was proposed by the National Technical Committee for Standardization of Insulating Materials. This standard is under the jurisdiction of Guilin Electrical Science Research Institute of the Ministry of Machinery Industry. This standard was drafted by Shanghai Electric Fiberglass Factory, and Nanjing Electric Fiberglass Factory participated in the drafting. The main drafters of this standard are Wang Yunyu and Sheng Yongqi. Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.