This standard specifies the test method for the pile length of hand-knotted carpets. This standard is applicable to hand-knotted carpets and can also be used as a reference for hand-tufted carpets. GB/T 15965-1995 Test method for the pile length of hand-knotted carpets GB/T15965-1995 Standard download decompression password: www.bzxz.net
Some standard content:
GB/T15965—1995 This standard adopts ISO2549:1972 "Determination of the length of tuft strands on the ground structure of hand-knotted carpets" in a non-equivalent manner. This test content is included in the inspection of hand-knotted carpets in my country. In order to get closer to international standards, combined with the structural characteristics of hand-knotted carpets in my country, ISO2549 is adopted in a non-equivalent manner. Explanation of the changes in the main technical contents between this standard and the international standard: The L-shaped pile length gauge is not convenient for on-site use and is not adopted. The fork-shaped gauge in my country is selected; in order to make up for the lack of regional selection in the inspection procedure, this standard supplements Article 7.4; in the calculation of the results, add the B method to calculate the deviation of each measuring point in order to provide the maximum deviation value. In 1988, my country adopted ISO2549:1972 equivalently to formulate ZBW56006-88 "Determination of the length of pile strands on the base of hand-knotted carpets" Explanation of the changes in important technical contents between this standard and ZBW56006-88: The pile length gauge is L-shaped, which is inconvenient to use on site and is not adopted. The fork-shaped gauge in my country is selected; some contents in the inspection procedure are modified accordingly with the change of the pile length gauge. "The selection of the test area is shown in Appendix A. It is cancelled and implemented according to QB1086--91. | |tt||From the date of implementation of this standard, ZBW56006--88 "Determination of the length of pile strands on the base of hand-knotted carpets" shall be abolished. This standard is proposed by the China Light Industry General Association. This standard is under the jurisdiction of the National Carpet Standardization Technical Committee. The drafting unit of this standard: Tianjin Carpet Research Institute. The main drafters of this standard are Zhang Lu and Li Xiaowen. 14 1 Scope National Standard of the People's Republic of China Test method for pile length of hand-knotted carpets Carpet -- Determination of length of pileWww.bzxZ.net This standard specifies the test method for the length of pile of hand-knotted carpets. This standard is applicable to hand-knotted carpets and can also be used as a reference for hand-tufted carpets. 2 Cited standards GB/T15965—1995 neq ISO 2549:1972 The provisions contained in the following standards constitute the provisions of this standard through reference in this standard. When this standard was published, the versions shown were valid. All standards are subject to revision, and parties using this standard should explore the possibility of using the latest versions of the following standards. QB1086--91 Sampling and selection of test areas for hand-knotted carpets 3 Definitions This standard adopts the following definitions. Length of pile pile The length of the pile tuft extending from the carpet base to the top. 4 Principle Insert the pile length gauge into the carpet surface, perpendicular to the carpet base to determine the scale value of the pile length corresponding to the gauge. 5 Measuring tool The pile length gauge has a range of 0 to 25 mm and a graduation value of millimeters. Approved by the State Administration of Technical Supervision on December 26, 1995 and implemented on December 1, 1996 6 Sample The whole carpet. 7 Inspection procedure GB/T 15965—1995 Pile length gauge 7.1 Select the test area on the carpet surface according to the provisions of Chapter 3 of QB1086-91, and measure each area once. R10 7.2 Insert the gauge between two vertical rows of piles, make the gauge perpendicular to the carpet base and stably contact, and measure the pile length. Accurate to 0.5mm, if the measured size is less than 0.5mm, it will be discarded. 7.3 If the carpet contains piles of different lengths due to its process requirements, measure them separately. 7.4 If it is found that the pile length outside the test area has obvious deviation, it should also be measured. If the deviation exceeds the deviation of the test area, the measurement data is valid. 8 Calculation and expression of results 8.1 Calculate different pile lengths separately. 8.2 There are two methods for calculating deviation, A and B. 8.2.1A method: --pile length deviation, mm, accurate to one decimal place); where: D- --arithmetic mean of measured pile length, mm (accurate to one decimal place); S --nominal pile length, mm. 8.2.2B method: D, = S, S (i= 1, 2...n) where: D;- --deviation of each pile length, mm (accurate to one decimal place); 1) GB/T15965—1995 S;. Actual measured value of each pile length, mm (accurate to 0.5mm). 9 Test report The test report should include the following contents: a) Explain that the test is carried out in accordance with this standard, and all details of any deviation from this test method; b) Fill in all the measured values performed in accordance with the requirements of this standard; c) Fill in the arithmetic mean and deviation of different pile lengths; d) Fill in the deviation of each different pile length when necessary. 17 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.