Introduction to standards:
This standard specifies the basic regulations, acceptance contents and warranty obligations for the surface layer of civil indoor wooden floor. This standard applies to the acceptance of the surface layer of civil indoor wooden floor, and also applies to disputes and arbitration caused by improper floor laying and changes in floor status. This standard does not apply to the acceptance of wooden floor laying with special requirements such as thermal insulation, floor heating, anti-static, radiation protection, and sports venues. This standard does not involve the acceptance of the base construction of wooden floor. WB/T 1016-2002 Acceptance specification for wooden floor laying surface layer WB/T1016-2002 Standard download decompression password: www.bzxz.net
This standard specifies the basic regulations, acceptance contents and warranty obligations for the surface layer of civil indoor wooden floor. This standard applies to the acceptance of the surface layer of civil indoor wooden floor, and also applies to disputes and arbitration caused by improper floor laying and changes in floor status. This standard does not apply to the acceptance of wooden floor laying with special requirements such as thermal insulation, floor heating, anti-static, radiation protection, and sports venues. This standard does not involve the acceptance of the base construction of wooden floor.
Some standard content:
S 03.080. 01
People's Republic of China Material Management Industry Standard WB/T 1016--2002
Accept standard for wood fluorimg surface after installation2002-09-02 Issued
National Economic and Trade Commission
200211-01 Implementation
WB/T 11016---2002
Wood floor is a common floor decoration material used in the decoration of shops and public buildings. With the sharp increase in its sales volume, complaints are also on the rise. In particular, with the reform of the housing system and the cancellation of the listing of rough houses, it is necessary to formulate basic requirements for the acceptance of the surface layer of wooden flooring. In order to standardize the technical flooring market and ensure product quality and laying quality, this standard is specially formulated. This standard is formulated based on a large number of investigations and studies, combined with the construction acceptance technical requirements of large-scale wood flooring production, distribution and decoration enterprises, and extensively soliciting opinions from all parties. This standard is proposed by the China Timber Circulation Association: The responsible drafting units of this standard are: China Timber Circulation Association, China Provincial Decoration Association, and China Building Decoration Association. The participating drafting organizations of this standard are: Beijing Shengxiang Bailong Decoration Materials Co., Ltd. (Shengxiang), Guangdong Yihua Wood Industry Co., Ltd. (Yihua), Tianjin Fuya Industrial Co., Ltd. (Fumandi), China National Overseas Personnel Service Corporation (Jia), Fucheng International Group (Gongli Digital King), Shunde Yingbin Industry Co., Ltd. (Nature), Bingjia Wood Industry Co., Ltd. (Shengchuan), Zhejiang Shaoxing Fudeli Industry Co., Ltd. (Fudeli), Beijing Hongnaishega Building Materials Co., Ltd. (Hongxie), Nanhai Jingcheng Technology Industry Co., Ltd. (Jingangying), Shanghai Jialemei Industry Co., Ltd. (Formosa Boulevard), Hangzhou Mingben Industry Co., Ltd. (Mingcheng). Who are the main drafters of this standard? Gao Zhihua, Wang Shuilin, Weng Shaobin, Liu Shaoxi, Zhang Yuniu, Yuan Shuai Yide, Zhang Jieqiang, Yu Xuebin, Xia Hailin, Errongfu, Li Wei, Yada Pu Zhiwen, Xia Yeming, and Si Jurong. 1 Specification for Acceptance of Wooden Flooring Surface Layer
This standard specifies the basic requirements for acceptance of civil indoor wooden flooring surface layer and warranty obligations w/r1016-2002
This standard applies to the acceptance of civil indoor wooden flooring surface layer, and also applies to disputes caused by improper floor installation and floor state changes.
This standard does not apply to the acceptance of flooring with special requirements such as thermal insulation, floor heating, anti-static, anti-radiation, and sports venues. This standard does not involve the acceptance of the base construction of local floors.
2 Normative references
The following documents become clauses of this standard through reference in this standard. For dated references, all subsequent amendments (excluding errata) or revisions are not applicable to this standard. However, parties that reach an agreement based on this standard are encouraged to study whether the latest versions of these documents can be used. For undated references, the latest versions are applicable to this standard. GB/T15036.1-2001 Technical conditions for solid wood flooring (B/T15036.2-2003 Inspection and testing methods for solid wood flooring) GB/T1S102:2000 Paper-coated laminated wood floor GB/T1803:2000 Solid wood composite floor LY/T1573-2000 Bamboo floor 3 Basic regulations 3.1 Basic requirements 3.1.1 Civilian indoor small floor includes: a) solid wood floor (including tongue-and-groove floor, flat floor, parquet floor, finger-jointed floor, integrated floor, etc.); b) solid wood composite floor (including three-layer solid wood composite and multi-layer solid wood composite); paper-coated laminated wood floor (laminate floor): 3.1.2 The quality of the wood floor used in the second floor should meet the requirements of G/T18103.GB/T18102, LY/T1573.GB/T15036./CB/T15036.2 respectively. Before installation, the quality and quantity should be approved by the user; the tree species, pattern, shape, moisture content, color, paint, size deviation, precision, formaldehyde content, etc. should also be approved. 3.1.3 The local floor laying method, technical steps, base materials, quality requirements, construction period, acceptance specifications, etc. should be approved by the user before installation, and the construction should be strictly implemented.
3.2 Basic requirements for the base of the technical site
3.2.1 Clean: no floating dust, no obvious construction waste, etc. 3.2.2 Flat: It should reach or be lower than the local equilibrium condensation and moisture content. Wet construction is strictly prohibited, and water sources should be prevented from leaking to the ground, such as heating outlets, kitchens and sanitary interfaces, etc. 3.2.3 Expansion: The 2m ruler should be less than 5mm. 3.2.4 Firmness: The base material should be high-quality and qualified products, and should be fixed to the foundation in order. Looseness is not allowed: The two ends of the keel should be nailed firmly and glued firmly. It is strictly forbidden to fill with cement mortar. The subfloor should be nailed all around, and the nail distance should be less than 350mm. wB/m1016---2002
3.2.5 Expansion joints: Expansion joints should be left between keels, between keels and walls, between subfloors, and between subfloors and walls. 3.2.6 Corrosion: Use flat baking and corrosion-resistant materials (width 35mm) as keel materials, and it is strictly forbidden to use fine wood 1. Board materials as keel materials. Use needle board materials and high-quality multi-layer plywood (thickness 9mI) as subfloor materials. It is strictly forbidden to use them as a whole sheet. If necessary, anti-corrosion paint treatment and anti-corrosion treatment must be carried out. 3.3 Construction Procedure
Strictly avoid intermixing with other indoor decoration and renovation projects when installing wooden flooring. 3.4 Environmental Awareness
Enhance environmental awareness and strictly prohibit the use of serious pollutants such as asphalt, tea phenol, etc. in indoor base layers. 3.5 Construction Prerequisites
All wooden flooring base layers should be accepted before the wooden flooring surface layer is installed, otherwise the second layer installation is not allowed. 3.6 Acceptance Time
The surface acceptance of wooden flooring should be accepted within three days after completion. 4. Surface layer acceptance content
4.1 Basic requirementsbZxz.net
4.1.1 The maximum length of each side of the suspended flooring should not exceed 8111. Adjacent floors should be left with expansion joints and bridges should be used for connection. The door should be partitioned
4.1.2 The surface of the wooden flooring should be clean, flat, without burrs or cracks, and the laying should be firm and not loose. 4.2 Allowable installation deviation of wooden floor surface dimensions See Table 1 for the allowable installation deviation of wooden floor surface dimensions. Table 1 Allowable installation deviation
Jointing depth
Jointing gap width
Shrinkage around
Solid wood floor
4.3 Measuring tools for allowable deviation of laying dimensions See Table 2 for the measuring tools for allowable shrinkage of laying dimensions. Allowable deviation
Laminated flooring
Table 2 Allowable deviation Measuring tools
Flatness
Splicing height difference
Splicing gap
Axial expansion line
Warranty obligations
2Ⅱ Ruler and ruler
Feeler gauge or coordinate micrometer
Technical composite flooring
Unit is ※
Technical flooring
No less than one measurement point in each room. After the floor is laid, the entrusting parties (user and construction) shall promptly inspect the surface of the laid floor, evaluate the overall quality of the installation and service quality, and sign for it. The laying contractor shall issue its warranty card (order) and commit to the obligations during the warranty period of the floor. 2
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.