title>GB/T 4324.9-1984 Chemical analysis of tungsten - Dimethylglyoxime gravimetric method for determination of nickel content - GB/T 4324.9-1984 - Chinese standardNet - bzxz.net
Home > GB > GB/T 4324.9-1984 Chemical analysis of tungsten - Dimethylglyoxime gravimetric method for determination of nickel content
GB/T 4324.9-1984 Chemical analysis of tungsten - Dimethylglyoxime gravimetric method for determination of nickel content
Basic Information
Standard ID:
GB/T 4324.9-1984
Standard Name: Chemical analysis of tungsten - Dimethylglyoxime gravimetric method for determination of nickel content
GB/T 4324.9-1984 Chemical analysis of tungsten - Determination of nickel content by dimethylglyoxime gravimetric method GB/T4324.9-1984 standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China Chemical analysis method of tungsten Determination of nickel content by dimethylglyoxime gravimetric method Methods for chemical analysis of tungstenThe dt methylglyoxime gravimetric method forthe determination of nickel contentThis standard is applicable to the determination of nickel content in tungsten powder and tungsten bars. Determination range: 0.20~1.50%. This standard complies with GB1467--78 "General Principles and General Provisions of Standards for Chemical Analysis Methods of Metallurgical Products". 1 Method Summary UDC 869.27 : 543 21 : 546.74 GB 4324.9—84 The sample is decomposed with sulfuric acid and ammonium sulfate, the main tungsten is complexed with citric acid, and nickel is precipitated with dimethylglyoxime at pH 8~9, and the content is determined by gravimetric method. 2. Reagents and materials Ammonium sulfate. Sulfuric acid (specific gravity 1.84). Ammonium hydroxide (specific gravity 0.90). Ammonium hydroxide (1+99). Citric acid solution (50%), filter and set aside. 2.5 Para-nitrophenol ethanol solution (1%). Butanedione ethanol solution (1%): weigh 1g butanedione in a beaker, add 100ml ethanol to dissolve, filter and dry into a brown 2.f bottle. pH test paper. 3: Instrument Crocket filter [No. 3 or No. 4 (30ml)]. . Sample Tungsten bar should be crushed and passed through a 120-day sieve. 6 Analysis steps 5.1 Three samples should be weighed for measurement during analysis. The measured values should be within the allowable difference in the room, and the average value should be taken. 5.2 Sample quantity Weigh 1.000g of sample. 6. 3 Blank test Carry out a blank test together with the sample. 5.4 Determination 5.4.1 Place the sample (4.2) in a 400ml beaker, add 7g of ammonium sulfate (2.1) and 10ml of sulfuric acid (2.2), place it in an electric furnace at high temperature. National Bureau of Standards 1984-04-12 Issued 1886-03-01 Implementation GB4324.9—84 Heat to dissolve, remove and cool to room temperature, rinse the surface blood and the beaker wall with water, and dilute to about 200ml. 5.4.2 Add 10 ml of citric acid solution (2.5), stir evenly with a glass, add 2 drops of p-nitrophenol ethanol solution (2.6), adjust the solution to yellow with ammonium hydroxide (2.3), and then adjust the pH to 8-9. Check with pH test paper (2.8). While stirring continuously, add 15-20 ml of diacetyl ethanol solution (2.7), cover with table blood, boil, remove, place in a boiling water bath and heat for 15 minutes, cut off the power supply, keep warm for 90-120 minutes, take off, and cool to room temperature. 5.4.3 Use a pre-measured constant Filter through a crucible filter (3.1), wash the beaker and precipitate with cold ammonium hydroxide solution (2.4) for about 10 times, then place the crucible filter (3.1) at 115~125°C and bake for 60 minutes, take it out and place it in a desiccator for a period of time, cool it to room temperature (about 60 minutes> Weigh and bake to constant weight. Calculate the percentage of nickel by subtracting the mass of the blank precipitate made with the sample from the mass of the precipitate. Calculation of analysis results Calculate the percentage of nickel by the following formula: Ni (%) =- Formula, m, Allowance Mass of nickel precipitate from diacetyl, g! bzxz.net Sample amount, g! Conversion factor for nickel diacetyl to nickel. m×0.2032 The difference in analysis results between laboratories should not be greater than the allowable difference listed in the table below. Nickel 0.20~0.80 >,80 ~1.50 Additional explanation, This standard was proposed by the Ministry of Metallurgy of the People's Republic of China. This standard was drafted by Zhuzhou Cemented Carbide. This standard was drafted by Zhuzhou Cemented Carbide Factory. The main drafters of this standard were Liu Tingdu and Tan Aiyun. ×100 Allowance From the date of implementation of this standard, the former Ministry of Metallurgical Industry Standard YB895-77 "Tungsten Chemical Analysis Method" will be invalid. 28 藕蝎稚17bzw.cn脆臂荷间他饮干藕颜红痕旅科5翅湖 17izw.com脆鲜粹 醫种沃蜂菜鹤轰鞋 1桌额60 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.