Shapes and dimensions of graphite electrode for emision spectrum

Basic Information

Standard ID: SJ/Z 3206.6-1989

Standard Name:Shapes and dimensions of graphite electrode for emision spectrum

Chinese Name: 发射光谱分析用石墨电极的形状和尺寸

Standard category:Electronic Industry Standard (SJ)

state:in force

Date of Release1989-02-10

Date of Implementation:1989-03-01

Date of Expiration:2010-01-20

standard classification number

Standard Classification Number:General>>Standardization Management and General Provisions>>A01 Technical Management

associated standards

Publication information

other information

Publishing department:Ministry of Electronics Industry of the People's Republic of China

Introduction to standards:

SJ/Z 3206.6-1989 Shapes and dimensions of graphite electrodes for emission spectroscopy SJ/Z3206.6-1989 standard download decompression password: www.bzxz.net
This general rule applies to the shapes and dimensions of various graphite electrodes used in spectral analysis.


Some standard content:

Guiding Technical Documents of the Ministry of Electronics Industry of the People's Republic of China Shape and size of graphite electrodes for emission spectroscopy This standard applies to the shapes and sizes of various graphite electrodes used in spectroscopy. Reference Standards
GB9259-88 Terminology of emission spectroscopy. 2 Dimensions and requirements
SJ/Z3206.6—89
The dimensions and deviations of the graphite electrodes before forming used in this standard shall comply with the provisions in Table 1 Table 1 Dimensions and deviations of graphite electrodes before forming Order
Nominal size
Φ6x30
$8×30
Φ10×30
$13×30
$15×30
+0.3,-0
+2.0,-1.0
Full length bending
Not more than,%
2.2 The deviations of the spectral analysis electrodes of various shapes and sizes formed by the above electrodes shall not be greater than the provisions in Table 1.
3 Shape and size
According to different purposes of use, the electrodes are divided into two categories: counter electrodes and sample electrodes. 3.1 The counter electrode is the electrode that is opposite to the self-electrode or the supporting electrode and does not contain the analytical sample. The counter electrode is represented by the code "D".
The shape and size of the counter electrode are shown in Figure 1: Approved by the Ministry of Electronics Industry of the People's Republic of China on February 10, 1989 and implemented on March 1, 1989
SJ/Z 3206.B—88
Figure 1 The shape and size of the counter electrode
3.2 The sample electrode is also called the supporting electrode, which is used to place the analytical sample. The sample electrode is represented by the code "S". The shape and size of the sample electrode are shown in Figure 2.
6±0.3
Additional instructions
SJ/z3206.689bzxZ.net
10to.3
The shape and size of the sample electrode
This standard was proposed by the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry. This standard was drafted by the Electronic Standardization Institute of the Ministry of Machinery and Electronics Industry. The main drafters of this standard are Zhao Changchun, Wang Jinxue and Huang Wenyu. 30±2
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.