SY/T 0540-1994 Types and basic parameters of heating furnaces in petroleum industry
Some standard content:
Industry Standard of the People's Republic of China
After rectification, this standard has been converted into the oil and gas industry standard. The standard number is: SY/T0540-94. This is hereby stated. ZB E97 003—90
Types and basic parameters of heating furnaces in the oil industry Issued on February 27, 1990
Ministry of Energy of the People's Republic of ChinabZxz.net
Implementation on July 1, 1990
1 Subject content and applicable model
Industry Standard of the People's Republic of China
Types and basic parameters of heating furnaces in the oil industry This standard specifies the type, parameter series, model spectrum and product model compilation method of heating furnaces. This standard is applicable to heating furnaces fueled by crude oil and natural gas in oil and gas field long-distance pipelines. 2 Types
2.1 According to the basic structure, it is divided into two categories, namely, fire-type heating furnaces and tubular heating furnaces. 2.1.1 Fire-tube heating furnaces are divided into:
a. Fire-type direct heating furnace:
b, fire-type indirect heating furnace.
2.1.2 Tubular heating furnaces are divided into:
a. Wen-type cylindrical tube heating furnace;
b, horizontal cylindrical tube heating furnace:
c, horizontal isotropic tube heating furnace.
.2 According to the type of heated medium, it is divided into:
a, crude oil heating furnace;
b, well product heating furnace,
c, production water heating furnace
d, natural gas heating furnace.
2.3 According to the type of fuel, it is divided into:
a. Gas heating furnace,
b, oil heating furnace:
c. Oil and gas heating furnace.
3 Integer series
3.1 Heating furnace load series:
ZB E97 003-—90
40,50,63,80,100,125,16D,200,250,315,400,500,630,800,10001250,1600(2000) .2500,(3150)40006 000.6300,8000.100001W,Note: (1) The heat load parameters in brackets are not used: 3.2 Heating furnace pressure level series
3.2.1 The nominal pressure level of the fire-type heating furnace shell is divided into: <0.1, 0.25, 0.40, 0.60MPa.
3.2.2 The design pressure level series of the mine pipe coil is 1.6, 2.5, 4.0, 6.4, (10.0), 16.0, 20.0, 25.0, 32.0, MFa. Note: The pressure parameter is not commonly used. 3.3 The nominal diameter (shell inner diameter) size series of the fire-type heating furnace body is: Approved by the Ministry of Energy of the People's Republic of China on February 27, 1990 and implemented on July 1, 1990
ZB E97 003-—90
800,1000,1200,1400,1600,18002000,2200,2400,2600,2800,3000,3200,3400,3600, (3800) mm.
Note: the size parameters in brackets are not often used. The commonly used diameter size series of 3,4 furnace tubes and coils are: 88, 60, 89, 102,
127, 152, 219,
279mm.
Medium and low pressure coils: 32, 38, 48, 60, 76, 89, 219.
114, 127,
High pressure coils: 42, 60, 76, 89, 108, 133, 159mm. 3.5 The nominal diameter size series of the fire tube is,
250, 300, 400, 450, 500, 600, 700, 800, 900, 1000mm. 3.6 The nominal diameter size series of the smoke diagram is,
200, 250300, 400, 450, 500, 600700, 800, 900, 1000, 1100, 1200mm. 4 Series model spectrum
The series model spectrum of the heating furnace is shown in Table 1.
5 Model compilation method of heating protection products
5.1 Model composition
The model of the heating furnace product consists of three parts. Each part is connected by a short horizontal line. AA
Design serial number
Fuel type code
Design pressure of coil or furnace tube
Heated medium code
Rated heat load
Model code
5.1.1 The first part of the model indicates the basic structure type and rated heat load of the heating furnace, which is divided into two sections. The first section uses Chinese phonetic letters to represent the basic structure type of the heating furnace, see Table 2, and the first section uses Arabic numerals to indicate the rated heat load of the heating furnace in watts. The two sections are written continuously and connected to each other.
5.1.2 The second part of the model is divided into two sections, which are separated by a slash. The first section uses Chinese phonetic letters to represent the type of heating medium, see Table 3, and the second section uses Arabic numerals to indicate the design pressure of the coil or furnace tube in MPa. The second section of the fire-type high-pressure heating furnace is not indicated. 5.1.3 The third part of the generation number consists of two sections: the first section uses the Chinese pinyin Ningmu to represent the type of fuel, see Table 4, and the second section uses Arabic numerals to indicate the design order, and the first design is not indicated. The two are not written in succession, and they are connected. 5.2 Examples
5.2.1HZ630-YQ heating buffer combined equipment indicates that the rated heat load is 630kW, the heating medium is crude oil, the fuel is natural gas, and the first design of the fire tube type direct heating buffer combined equipment.
5.2.2 HJB3--H/1.6-Q heating furnace
Indicates that the rated heat load is 63kW, the heating medium is well products, the design pressure of the coil is 1.6MPa, the fuel is natural gas, and the first 2
Number of varieties
(6052)
20909100
ZBE97 003--90
Large cylinder type heating furnace
Type heating furnace
Basic structure of heating furnace
Fire cylinder type heating furnace
Tube type heating furnace
Cell type heating furnace
Heated medium
Production water
Natural gas
Well product
Fuel type
Natural gas
Dual use of oil and gas
ZB E97 003—90
Table 2 Basic structural type code of heating furnace
Fire tube type direct heating furnace
Extinguished tube type indirect heating furnace
Vertical tubular heating furnace
Horizontal tubular heating furnace
Heated medium code
Table 4 Fuel type code
Second design of fire tube type indirect heating furnace.
6.2.3GL4000-Y/2.5—YQ2 heating furnace indicates that the rated heat load is 4000kW, the heating medium is crude oil, the design pressure of the furnace tube is 2.5MPa, and the fuel is oil and gas. The second design of the vertical tubular heating furnace. 5.2.4G2500--S/2.5-Q Heating Furnace
indicates a horizontal tubular heating furnace with a rated heat load of 2500kW, production water as the heating medium, a furnace tube design pressure of 2.5MPa, and weather as the fuel, designed for the first time. Additional Notes:
This standard was proposed by the Planning and Design Institute of China National Petroleum Corporation. This standard was drafted by Qianhe Petroleum Design and Research Institute.