This standard includes all technical requirements and test methods of the test specifications of the German Delimon Company. In addition, according to the actual domestic situation, the assessment items such as cleanliness and life have been added, and the corresponding test methods have been added. This standard specifies the model, basic parameters and dimensions, technical requirements, test methods, inspection rules and signs, labels and packaging of progressive distributors 16MPa. This standard is applicable to progressive distributors in single-line progressive dry oil centralized lubrication systems with a nominal pressure of 16MPa. JB/T 8464-1996 Progressive distributor 16MPa JB/T8464-1996 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China JB/T 8464--96 Progressive Distributor 1996·09-03 Issued 1997-07-01 Implementation Ministry of Machinery Industry of the People's Republic of China JB/T8464 This standard is based on the whole technical six test methods of the test specification of the State-owned Assets Supervision and Administration Commission of the State Council, and the test methods such as service life are increased according to the actual domestic situation, and the corresponding test methods are increased. This standard is put forward by the Institute of Safety and Resilience and belongs to the following units: Shanghai Attached Company! . This standard mainly includes the following: Shen Zhong ■Scope Machinery Industry Standard of the People's Republic of China Progressive distributor JB/1846496 Generally speaking, the speed of the distributor is changed. The parameters and appearance of the standard are shown, the requirements for release, the case support, the inspection and verification, the labeling and packaging. This standard applies to the progressive distributor in the 16MPa single-line type ten-point system. 2 Reference standards The provisions contained in the underlined standards are quoted in this standard and become the adopted text of this standard. When this standard is published, the version shown is valid. The changed parts of the standard will be changed. Therefore, all parties using this standard should control the possibility of using the latest version of the underlined standard: G9? General classification of Baiyou products ZB1023R7 Lubricant modification component labeling, packaging, transportation, storage specifications 1 Model, basic parameters and dimensions 3.2 Basic changes Sea oil supply port to determine the amount of powder oil: r/anti-pressure, etc. Line number: 16Pg Reverse distributor Oil one number The basic parameters of the distributor should be in accordance with the current requirements in Table 1, 1 ×1FQ1-K × X[PO2-K× ×JFQ:-K× Nominal pressure 3.3 Overall dimensions Use uniform quality Lubricating station Good to give the product natural blood =T/time oot .t. 2,t.3 0. 01c.1.. 2,4. 3 0.51,9.2.0 Number of combinations 3.3.11PG1 single control pipe step).G3 type overall dimension drawing: and Meng. Approved by the Ministry of Machinery Industry in March 1996, Cold Shantou Port, June 21, Suitable for wet filling, 20-1-30, implemented on July 1, 1997, Luoyou Port, I8/T 846496, Room 1JFQ1.JHQ External dimensions: See Figure 2 and table for the external dimensions of 1PQ2 type, and the accrual card Figure 9PQ2 external dimensions. : I talk about the mouth Age oil two-effect 3. 3. 3JPQ type - shape dimension table 3 benefit figure = 21 JR/T 846496 Medical P type shape dimension Number of oil supply ports 1> 4 Technical requirements Dynamic pressure of the device M 4.2 Sealing The back pressure of the distributor outlet is 1MPa, and there shall be no German screening phenomenon at its joints and sealing parts. 4. Loss volume Hong Kong book shows the coupon Under the pressure of 12MPk, the loss of each oil supply port of the distributor is: JPQ1..IFQ3 types are not more than 1mlmin, TPQ2, JPQ4 types are more than 1.5nLin 4.4 Supply test pad JB/T8464-96 When the back pressure of the distributor port is 10MP and 3MP, the total push-up volume of the injection door is 5 Zhaoding. Table 5 XJPQ3K ×JPQ2-× ×JP4-× 4.5 Degree of viscosity Number of fixed oil Moisture content Real oil resistance; 5, 5~u, : 5. R5 -- 1. 35 1. 34-2. 5 :.c--3. 2a 3. 4--h. 3 e. 1~15. c 13.5-45. 0 Indicates that the oil is ready 0. 36 -- 5, 5 1. 1~.2.25 1. 5a-- 3. + .. F--5. 5 7. 5-- 4. 3 12. 7-- 24. The impurity mass removed from each dispenser: JFQ1JFQ: Type not more than 25mgJPQ3JTQ Type + g: 4.6 Life The service life of the dispenser is not less than 150 cycles: When the value exceeds 11 and drops below the minimum value specified in the table, it is considered to be the use limit of the dispenser. STest method 5.1 Test medium The test medium of the distributor is N63 oil (except for the test medium, the oil supply is 120t.na. 5.2 Test principle The test system principle of the distributor is shown in Figure 4. 5.3 Pressure test Start the oil pump, and the distributor moves 2 times. Loosen the two holes and close the two screws to discharge the air. Test the pressure gauge, and its indication should meet the current requirements of small 1. 5.4 Sealing test Re-adjust the back pressure of all oil outlets of the distributor to 10M, run rn, and visually check the external seals of the distributor. There should be no reading phenomenon. ||t t||5.5 Test the oil volume Block all the feed pools, adjust the pressure of the feed pool to 1Pa and run for 3mi-respectively. The average compensation should meet the requirements of 4.3. 5.6 Test the oil tray Adjust the oil pressure of the two pieces to 1CMPs, and the two pieces of the even number to 3MPE. Test each feed pool! U change the momentum. Then adjust the oil back pressure on both sides of the odd number to 3MP: adjust the oil back pressure of the oil outlet to 10MP and then test the oil outlet 18 times. The values should meet the requirements of 1,4. 5. T Clearance Method | |tt||Disassemble the distributor, wash all the parts with the changed aldehyde, filter the petroleum scale with the discarded paper with fixed weight after drying in the oven at 12℃ for 60min and weigh it, then put the paper with a low concentration of 1g in the box and weigh the paper before and after the test. The value should meet the requirements of 4. 5.B Life test JH/T8464-96 1-Electric lubrication pump, a negative force of 3: 5: 5. The test reverse distributor diagram compensation system principle General configuration life test It should be carried out on a test bench certified by the Cat. The test medium is a grease with a final penetration of 25 (2>, 15/10mm. The oil supply ports on both sides of the single number are adjusted to 10MP. The double-effect film on both sides is adjusted to 3MT. After running for 10 cycles, the drip test is carried out in accordance with the provisions of 5.6. The value should still comply with the provisions of 4.4. 6 Inspection rules 6.1 Factory inspection The factory inspection of the distributor is carried out in accordance with the frequency of 5.2 and 5.4. 6.2 Type inspection However, .2.1 has reached the deadline, and the type inspection should be carried out: the first trial production. Type identification resistance: JB/T 8464-96 b) When the selection of medicinal trees and materials has an impact on the quality of the products; c) When the products have been produced for five years. bZxz.net 6.2.2 The products for type inspection shall be taken from the tested products, and the number of each product shall be one piece. 6.2-3 Type inspection shall be carried out according to the requirements of the 5th item. 6.3 Judgment This type inspection shall be given to the old products. If there is no conformity, it shall be regarded as a defective product. Marking, labeling and packaging The marking and packaging of the group shall be in accordance with the provisions of ZBJ08. Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.