JB/T 2001.59-1999 Minimum liquid level valve core for water system pump station (PN=20, 31.5MPa)

Basic Information

Standard ID: JB/T 2001.59-1999

Standard Name: Minimum liquid level valve core for water system pump station (PN=20, 31.5MPa)

Chinese Name: 水系统 泵站用最低液面阀芯(PN=20、31.5MPa)

Standard category:Machinery Industry Standard (JB)

state:in force

Date of Release1999-06-28

Date of Implementation:2000-01-01

standard classification number

Standard ICS number:Fluid systems and general parts >> 23.100 Fluid power systems

Standard Classification Number:Machinery>>General Parts>>J20 Hydraulic and Pneumatic Devices

associated standards

alternative situation:JB 2062-1984

Publication information

other information

Focal point unit:Metallurgical Equipment Standardization Technical Committee

Introduction to standards:

JB/T 2001.59-1999 JB/T 2001.59-1999 Minimum liquid level valve core for water system pump station (PN=20, 31.5MPa) JB/T2001.59-1999 Standard download decompression password: www.bzxz.net

Some standard content:

IC.s$ 23.110
Machinery Industry Standard of the People's Republic of China
JB/T 2001.1~2001.74—1999
Water system components
Water system assembly and parts1999-06-28 Issued
State Machinery Industry Bureau
2(-01-U1 Implementation
Machinery Industry Standard of the People's Republic of China
Minimum liquid level valve core for water system pump station
Watersystem-
|-Eoreof lorestlevevaveforwaleresuulnlor[ PN=20, 31.5 MPa ]
1Scope
This standard specifies the type, size and technical requirements of minimum liquid level valve core.JB/T 2001.59-1999
Replacement 20624
The standard is applicable to the nominal pressure of 20, 31.5MPa, and the minimum water level of the emergency closure when the temporary curtain occurs is the lowest. 2 Reference standards
The provisions contained in the underlined standards constitute the provisions of this standard through use in this standard. When this standard is published, the version shown is valid. All standards will be reviewed and revised. All parties using this standard should discuss the possibility of using the following standards to meet the latest version. JB.T2001.19-1999 Water system venting width type and size (PN. 50MPa) 3 Type and size
The type and size of the minimum liquid front mesh core shall be in accordance with the provisions of Table 1. MKd
All rainwater holes
Public enterprises to read and make several
1 Use: 2 Vent two 1 type; 3-due to attachment flange 4-sample whole-0 shape density diagram: -: 7-[1 shape density: 8-ring: 9 read: 10 read the embrace; 11-adjustment rate: 12-0 shape diagram; 13-rate rod; [4-nut National Machinery Industry Limited 1999-06-28 approved 162
2000-01-01 implementation
18 2K1:91
JB.T 20G1.59.2
J3-T20C1.59.3
1B/T2001.59.4
14/1 21111 19.3
IBT2001.5.6
JB/T20D1.59.1
JH/12001.59.
日/T 2C01 50.4
2c01.59.swwW.bzxz.Net
JB.T2G01.59.6
Technical requirements
JR/T2001-59-1999
4.1 Nominal 31.5MFa, test force 42MPa. Nominal pressure 26Mra: test force 30Mra.d,
ni × d
8×M30
6 x× M42 × 3
×M4?×3
H×M18×+
× M50 ×*
4.7: The pressure of the test liquid should be consistent with that of the working liquid, and there should be no leakage or movement at the seal and valve 1. 4.3 2 in Figure 1 (the deflation pressure should be in accordance with the provisions of JB/T2001.19 for the type deflation pressure) -5 mark indicates the minimum liquid level of the nominal diameter 65m: the minimum liquid level is DV65JB.T2001.59-1999105
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.