title>QB 1965-1994 Mast Light - QB 1965-1994 - Chinese standardNet - bzxz.net
Home > QB > QB 1965-1994 Mast Light
QB 1965-1994 Mast Light

Basic Information

Standard ID: QB 1965-1994

Standard Name: Mast Light

Chinese Name: 桅灯

Standard category:Light Industry Standard (QB)

state:in force

Date of Release1994-06-10

Date of Implementation:1995-02-01

standard classification number

Standard Classification Number:Light Industry, Cultural and Living Supplies>>Hardware Products>>Y73 Daily Hardware Products

associated standards

alternative situation:ZB Y73027-89

Publication information

publishing house:China Light Industry Press

Publication date:1995-02-01

other information

drafter:Zhang Zishuo, Shen Jun

Drafting unit:Shanghai Mast Lamp Factory, Yangzhou Mast Lamp Factory, Wuhu Mast Lamp Factory

Focal point unit:National Daily Hardware Standardization Center

Proposing unit:Quality Standards Department of Ministry of Light Industry

Publishing department:Ministry of Light Industry of the People's Republic of China

Introduction to standards:

This standard specifies the product classification, technical requirements, test methods, inspection rules and marking, packaging, transportation, storage, etc. of masthead lights. This standard applies to various masthead lights that use kerosene as fuel for nighttime lighting or signal warning. QB 1965-1994 Masthead Light QB1965-1994 Standard download decompression password: www.bzxz.net

Some standard content:

Light Industry Industry Standard of the People's Republic of China
Subject Content and Scope of Application
QB1965-1994
This standard specifies the product classification, technical requirements, test methods, inspection rules and marking, packaging, transportation, storage, etc. of gun lamps. This standard applies to various olive lamps that use kerosene as fuel for nighttime lighting or signal warning. 2 Reference Standards
GB191 Pictorial Marks for Packaging, Storage and Transportation
GB253 Kerosene
GB/T2828 Batch Inspection Count Sampling Procedure and Sampling Table (Applicable to Inspection of Continuous Batch) GB/T2829 Periodic Inspection Count Sampling Procedure and Sampling Table (Applicable to Inspection of Production Process Stability) GB5938 Corrosion Resistance Test Method for Metal Coatings and Chemical Treatment Layers of Light Industrial Products Neutral Salt Spray Test (NSS) Method GB5944 Evaluation of Corrosion Test Results of Metal Coatings of Light Industrial Products GB/T6388 Shipping and Receiving Marks for Transport Packages
3. Product Classification
3.1 Lamps are divided into two categories according to the surface coating: tin lamps and lacquer lamps. 3.2 Olive lamps are divided into five types according to the specifications: extra large, large, second, third and high cover. 3.3 Models of olive lamps and their meanings
-Surface coating code
Specification code
The Chinese phonetic prefixes "X" and "Q" are used to represent small tin lamps and lacquered lamps respectively. The Chinese phonetic prefixes "T", "D", "E", "S" and "G" are used to represent the product codes of extra-large, large, second, third and high-shaded lamps respectively
Example: Large tin-plated olive lamp, WDX.
3.4 ​​Basic parameters
The basic parameters of olive lamps shall comply with the provisions of Table 1. Item
Height (distance from the top cover to the bottom of the oil pot)
Maximum width (the widest distance from the outer edge of the air column) Rated oil storage capacity
Rated burning time (at rated luminous intensity) Unit
The Chinese phonetic prefix "W" of the olive lamp is used to represent the product code of the extra-large, large, second, third and high-shaded lamps respectively. " indicates Table 1
Nominal value
Nominal value deviation
Nominal value
Nominal value
Approved by the Ministry of Light Industry of the People's Republic of China on June 10, 1994 466
Implementation on February 1, 1995
4 Technical requirements
4.1 Luminous performance
QB1965-1994
The maximum luminous intensity of the olive lamp should not be less than that specified in Table 2. Table 2
Maximum luminous intensity
4.2 Flame stability
After the flame stability test, the flame of the olive lamp should not smoke and have no obvious deformation. 4.3 Anti-drop performance
After the anti-drop test, the flame of the olive lamp shall not be extinguished. W s
4.4 Temperature rise
After the temperature rise test, the temperature rise of all metal parts of the olive lamp, except the top cover and the jacket, shall not exceed 30℃. 4.5 Wind resistance
The wind resistance of the gun lamp shall not be lower than the requirements of Table 3. Table 3
Wind resistance
4.6 Protection performance
After the protection performance test, the lampshade shall not be damaged. WD
4.7 Anti-oil leakage performance
The bottom seal of the olive lamp oil pot shall be tight and smooth, and the riveting of the oil filling port and the air column to the oil pot shall be tight and firm, and there shall be no oil leakage. KNKca
4.8 Appearance quality
4.8.1 The outer surface of the olive lamp is not allowed to have more than three cancer marks longer than 8mm, and pull marks that seriously affect the appearance. There shall be no burrs or sharp edges that may hurt the skin. The riveting of the lamp frame shall not be obviously skewed. 4.8.2 The outer surface of the tin lamp shall not have serious surface tin, black spots and rust spots. 4.8.3 The outer surface of the paint lamp shall be bright and uniform in color, and the paint film shall be of uniform thickness. No paint leakage or paint flow is allowed. There shall be no obvious defects such as paint hanging, bubbles, orange peel, pinholes and impurities.
4.9 The corrosion resistance of the tinned metal coating of the tin lamp shall be not less than level 5 after a 4-hour neutral salt spray test. 4.10 Paint film adhesion of the paint lamp
After the paint film adhesion test, there shall be no paint film shedding. 4.11 Performance in use
4.11.1 The wrench shall be flexible to turn and self-locking shall be reliable. When turning, the lampshade shall not get stuck on the burner. 4.11.2 When the wick handle rotates in the forward and reverse directions, the wick belt should be flexible in lifting and lowering, and stagnation, reversal, and slipping are not allowed. 5 Test method
5.1 Luminous performance test
Pour kerosene that meets the requirements of GB253 into the olive oil pot, let it stand for 15 minutes, then ignite it, and place it in the dark box shown in Figure 1. Adjust the 467
QB19651994
lifting screw so that the flame position is on the same horizontal plane as the illuminance meter probe, and rotate the worm gear handle to make the gun lamp rotate slowly around the lamp axis. The maximum illuminance value (Ix) measured by the illuminance meter probe with a range of 101x and an accuracy of 0.11x at a distance of 1m from the pillow lamp is converted into the maximum luminous intensity value (cd) (the measurement distance is 1m, and the luminous intensity value is equal to the illuminance value). Illuminance meter
1 banana cover; 2- air hole + 3- comb lamp * 4 lifting nut + 5 mounting box * 6- worm gear pair 5.2 flame stability test
After the lamp is lit, adjust it to the rated luminous intensity (maximum luminous intensity minus 1cd), and observe it after 3 hours. 5.3 anti-drop test
After the static burning test in 5.2 is passed, it is suspended from a height of 150mm and falls freely on the material board for observation. 5. 4, temperature rise test
After the olive lamp is statically burned, adjust it to the rated luminous intensity, and at the same time, hang mercury thermometers at three different positions in the horizontal direction 1m away from the olive lamp. After 3 hours, measure the average value of the thermometer readings at the three locations, which is the ambient temperature of the laboratory. And use the photometer to read the surface temperature of the lamp ring and the wick handle. The difference between the surface temperature and the ambient temperature is the temperature rise. 5.5 Wind resistance test
Adjust the olive lantern to the rated luminous intensity, let it stand for 15 minutes, and then put it in a test environment where the wind speed can be adjusted. Adjust it to the rated wind speed specified in Table 3. Adjust the position of the olive lantern to rotate around the axis of the gun lamp so that the wind speed direction is aligned with the oil filling port side, and four directions of 90°, 180° and 270° from the oil filling port side. Each direction is tested for 10 seconds, and the flame should not go out. 5.6 Protection performance test
Hang the top of the lantern ring on the hook of the test frame, so that the axis of the olive lantern is 45° off the vertical direction. After loosening, swing the gun lamp until the intersection of the wire guard collides with the hardwood surface, and observe (Figure 2). 468
QB1965-
Impact surface
5.7 Anti-leakage oil test
Fill the olive lamp with the rated oil storage, wipe the surface, and place it on white paper. After 1 hour, observe and check whether there is oil stain on the white paper. 5.8 Appearance quality inspection
Appearance quality is visually inspected by hand.
5.9 Tin lamp tinned metal coating corrosion resistance test adopts neutral salt spray test, which is carried out according to the method and procedure specified in GB5938 and evaluated according to GB5944. TKKAa
5.10 Paint film adhesion test
Use a blade to cut four scratches on the flat paint layer horizontally and vertically to the surface of the substrate to form 9 small squares, each of which has an area of ​​1mm, and then stick it with medical adhesive tape. After sticking it firmly, slowly pull off the adhesive tape and check whether the paint film has fallen off. 5.11 Performance inspection
Operate the olive lamp wrench and wick handle 10 times each by hand, and no abnormality is allowed. 6 Inspection rules
6.1 The olive lamp inspection is divided into factory inspection and type inspection, and the number of unqualified products per 100 units is counted. 6.2 Factory inspection is carried out in accordance with GB/T2828, using a normal inspection one-time sampling plan. The inspection items, unqualified classification, inspection level, and qualified quality level are shown in Table 4. The sample size and judgment array are shown in Table 5. Table 4
Clause of this standard
Inspection items
Oil leakage prevention performance
Performance in use
Appearance quality
Unqualified classification
Technical requirements
Test method
Inspection level IL
Qualified quality level (AQL)
501~1200
1201~3200
3201~10000
10001~35000
Sample size
QB 19651994
AQL = 2. 5
Sample size
AQL= 6. 5
Sample size
AQL-10
6.3 When the batch is judged as qualified after the factory inspection, the delivery party shall replace the unqualified products with qualified products before submission; if it is judged as an unqualified batch, the batch of products shall be reworked by the delivery party before submission for inspection. When re-inspected, a strict inspection and sampling plan shall be adopted. 6.4 Type inspection
Type inspection shall be carried out in any of the following situations. 6.4.1
Test and finalization of new products or old products for transfer to factory production; after formal production, if there are major changes in structure, materials, and processes that may affect product performance; in continuous production, no less than once a year; when the product is resumed after a long period of suspension; when the factory inspection results are significantly different from the last type inspection; when the national quality supervision agency proposes type inspection requirements. Type inspection is carried out in accordance with the provisions of GB/T2829, using a single sampling plan with discrimination level I. Samples are drawn from the factory inspection qualified batch 6.4.2
. The inspection items, unqualified classification, unqualified quality level, sample size and judgment array are shown in Table 6. Table 6
Oil leakage prevention performance
Flame stability
Performance in use
Luminous intensity
Anti-drop performance
Wind resistance
Protective performance
Appearance quality
Anti-corrosion ability of tin lamp
Paint film adhesion of paint lamp
Unqualified classification
Clause of this standard
Technical requirements
Test method
Unqualified Quality level (RQL)
Sample size n
Judgment array
QB1965-1994
6.4.3 When the type inspection is unqualified, the type inspection can be carried out again with the permission of the superior quality supervision agency under the following circumstances:
When the inspection result is affected by the failure of the test equipment or the operating error; When the inspected enterprise requests re-inspection;
c. After the enterprise takes necessary corrective measures. 7 Marking, packaging, transportation and storage
Except for products exported under special agreements with manufacturers, they shall comply with these regulations. 7.1 Marking
7.1.1 Product marking
Each product shall be clearly marked with the following: a. Product model or article number;
Trademark.
7.1.2 Packaging Marks
The following contents shall be clearly marked on the outer surface of the packaging box: a.
Manufacturer name,
Product name;
Product model or article number;
Trademark;
Factory date or production batch number;
Standard number:
Expiration date;
Mass (gross weight) including packaging materials, kg; Quantity of products in each box;
Outer dimensions of the packaging box: lXb×h, cm; Shipping mark for transport packaging in accordance with GB/T6388; Packaging storage and transportation graphic marks such as "Handle with care" and "Avoid moisture" in accordance with GB191. 7.2 Packaging
7.2.1 Inner packaging
The inner packaging is wrapped in heat shrink film with a certificate of conformity. 7.2.2 Outer packaging
The outer packaging shall be made of corrugated paper boxes, and protective measures shall be taken for the intervals between the olive lanterns. The boxes shall be sealed and taped after packing. 7.3 Transportation
During transportation, the lamps shall be prevented from being dropped or exposed to rain. Heavy objects squeezing and violent vibrations are strictly prohibited. 7.4 Storage
The olive lanterns shall be stored in a clean and ventilated environment with a temperature not exceeding 40°C and a relative humidity not exceeding 85% without opening the original packaging. There shall be no corrosive gas around them. The packaging shall be at least 200mm away from the ground and the wall. Under normal conditions, the shelf life of the olive lanterns is half a year from the date of leaving the factory.
A1 Main overall dimensions and installation dimensions
QB1965-1994
Appendix A
Olive lampshade
(reference)
The main overall dimensions and installation dimensions of the olive lampshade shall comply with the provisions of Schematic Diagram A1 and Table A1, and shall be produced and accepted according to the production drawings. di
$117±0.5
$103±0.5
$85±0:
$70.5±1.0
$32.5±1.0
$66.5±1.0
$86.5±0.5
g59.5±1.0
A2 Technical requirements
QB1965--1994
The main technical requirements for olive lampshades shall comply with the provisions of Table A2. Table A2
Thickness of upper mouth, mm
Thickness of lower mouth, mm
Thickness of flare, nn
Upper mouth deflection, mm
Lower deflection, mm
Thermal stability
1. 3- 2. 5
180±15
90±10
$4mm or less, no more than 3, sample
20mm or more
.5mm or less, no more than 1 or
1. 0~2. 5
60±10
No more than 3 below 3mm or no more than 1 below 5mm, no more than 2 above 20mm
No more than 3 below 1mm, no more than 20mm apart
40±10
No more than 2 below 4mm, no more than 2 below 20mm apart Above
Not||More than
Under 1mm, not
More than 1
Under 50.5mm, not
limited, but not densely
White or light green, clear
Not allowed
Excited to 100℃ and put into 20℃ water without breaking. Purple or pink under stress meter
100±10
Not||More than 3 under 4mn.
More than 3 at a distance of
20mm
Clear 1.5m or less.
Not more than 3 at a distance of
20mm or more
B1 material
100% cotton yarn.
B2 Technical requirements
QB1965--1994
Appendix B
Wick band of olive lamp
(reference)
Basic parameters of olive lamp wick band shall comply with the provisions of Table B1. Table B1
Additional notes:
Branch/strand
Branch/strand
This standard is proposed by the Quality Standards Department of the Ministry of Light Industry. Weft
Branch/strand
Basic parameters
Shuttle/25.4mm
This standard is under the jurisdiction of the National Daily Hardware Standardization Center. This standard was drafted by Shanghai Olive Lamp Factory, Yangzhou Lamp Factory and Wuhu Gun Lamp Factory. ±2
Width, mm
Basic parameters
Thickness, mm
Basic parameters
The main drafters of this standard are Zhang Zishuo and Shen Jun. From the date of implementation of this standard, the professional standard ZBY73027-1989 "Olive Lantern" issued by the former Ministry of Light Industry will be invalid. 474
Manufacturer name,
Product name;
Product model or article number;
Trademark;
Factory date or production batch number;
Standard number:
Validity period;
Mass (gross weight) including packaging, kg; Quantity of products in each box;
Outer dimensions of packaging box: lXb×h, cm; Shipping mark for transport packaging in accordance with GB/T6388; Packaging storage and transportation graphic marks such as "handle with care" and "afraid of moisture" in accordance with GB191. 7.2 Packaging
7.2.1 Inner packaging
Inner packaging is made of heat shrink film with certificate of conformity attached. 7.2.2 Outer packaging
Outer packaging is made of corrugated paper box, protective measures are taken for the interval between olive lights, and the box is sealed and taped after packing. 7.3 Transportation
During transportation, the lamp should be prevented from being dropped or hit by rain. Heavy objects and severe vibration are strictly prohibited. 7.4 Storage
The lamp should be stored in a clean and ventilated environment with a temperature not exceeding 40℃ and a relative humidity not exceeding 85% without opening the original packaging. There is no corrosive gas around it. The packaging should be at least 200mm away from the ground and the wall. Under normal conditions, the shelf life of the lamp is half a year from the date of leaving the factory.
A1 Main dimensions and installation dimensions
QB1965-1994
Appendix A
Olive lamp cover
(reference)
The main dimensions and installation dimensions of the olive lamp cover should comply with the provisions of Schematic A1 and Table A1, and should be produced and accepted according to the production drawings. di
$117±0.5
$103±0.5
$85±0:
$70.5±1.0
$32.5±1.0
$66.5±1.0
$86.5±0.5
g59.5±1.0
A2 Technical requirements
QB1965--1994
The main technical requirements for olive lampshades shall comply with the provisions of Table A2. Table A2
Thickness of upper mouth, mm
Thickness of lower mouth, mm
Thickness of flare, nn
Upper mouth deflection, mm
Lower deflection, mm
Thermal stability
1. 3- 2. 5
180±15
90±10
$4mm or less, no more than 3, sample
20mm or more
.5mm or less, no more than 1 or
1. 0~2. 5
60±10
No more than 3 below 3mm or no more than 1 below 5mm, no more than 2 above 20mm
No more than 3 below 1mm, no more than 20mm apart
40±10
No more than 2 below 4mm, no more than 2 below 20mm apart Above
Not||More than
Under 1mm, not
More than 1
Under 50.5mm, not
limited, but not densely
White or light green, clear
Not allowed
Excited to 100℃ and put into 20℃ water without breaking. Purple or pink under stress meter
100±10
Not||More than 3 under 4mn.
More than 3 at a distance of
20mm
Clear 1.5m or less.
Not more than 3 at a distance of
20mm or more
B1 material
100% cotton yarn.
B2 Technical requirements
QB1965--1994
Appendix B
Wick band of olive lamp
(reference)
Basic parameters of olive lamp wick band shall comply with the provisions of Table B1. Table B1
Additional notes:
Branch/strand
Branch/strand
This standard is proposed by the Quality Standards Department of the Ministry of Light Industry. Weft
Branch/strand
Basic parameters
Shuttle/25.4mm
This standard is under the jurisdiction of the National Daily Hardware Standardization Center. This standard was drafted by Shanghai Olive Lamp Factory, Yangzhou Lamp Factory and Wuhu Gun Lamp Factory. ±2
Width, mm
Basic parameters
Thickness, mm
Basic parameters
The main drafters of this standard are Zhang Zishuo and Shen Jun. From the date of implementation of this standard, the professional standard ZBY73027-1989 "Olive Lantern" issued by the former Ministry of Light Industry will be invalid. 474
Manufacturer name,
Product name;
Product model or article number;
Trademark;
Factory date or production batch number;
Standard number:
Validity period;
Mass (gross weight) including packaging, kg; Quantity of products in each box;
Outer dimensions of packaging box: lXb×h, cm; Shipping mark for transport packaging in accordance with GB/T6388; Packaging storage and transportation graphic marks such as "handle with care" and "afraid of moisture" in accordance with GB191. 7.2 Packaging
7.2.1 Inner packaging
Inner packaging is made of heat shrink film with certificate of conformity attached. 7.2.2 Outer packaging
Outer packaging is made of corrugated paper box, protective measures are taken for the interval between olive lights, and the box is sealed and taped after packing. 7.3 Transportation
During transportation, the lamp should be prevented from being dropped or hit by rain. Heavy objects and severe vibration are strictly prohibited. 7.4 Storage
The lamp should be stored in a clean and ventilated environment with a temperature not exceeding 40℃ and a relative humidity not exceeding 85% without opening the original packaging. There is no corrosive gas around it. The packaging should be at least 200mm away from the ground and the wall. Under normal conditions, the shelf life of the lamp is half a year from the date of leaving the factory.
A1 Main dimensions and installation dimensions
QB1965-1994
Appendix A
Olive lamp cover
(reference)
The main dimensions and installation dimensions of the olive lamp cover should comply with the provisions of Schematic A1 and Table A1, and should be produced and accepted according to the production drawings. di
$117±0.5
$103±0.5
$85±0:
$70.5±1.0
$32.5±1.0
$66.5±1.0
$86.5±0.5
g59.5±1.0
A2 Technical requirements
QB1965--1994
The main technical requirements for olive lampshades shall comply with the provisions of Table A2. Table A2
Thickness of upper mouth, mm
Thickness of lower mouth, mm
Thickness of flare, nn
Upper mouth deflection, mm
Lower deflection, mm
Thermal stability
1. 3- 2. 5
180±15
90±10
$4mm or less, no more than 3, sample
20mm or more
.5mm or less, no more than 1 or
1. 0~2. 5
60±10Www.bzxZ.net
No more than 3 below 3mm or no more than 1 below 5mm, no more than 2 above 20mm
No more than 3 below 1mm, no more than 20mm apart
40±10
No more than 2 below 4mm, no more than 2 below 20mm apart Above
Not||More than
Under 1mm, not
More than 1
Under 50.5mm, not
limited, but not densely
White or light green, clear
Not allowed
Excited to 100℃ and put into 20℃ water without breaking. Purple or pink under stress meter
100±10
Not||More than 3 under 4mn.
More than 3 at a distance of
20mm
Clear 1.5m or less.
Not more than 3 at a distance of
20mm or more
B1 material
100% cotton yarn.
B2 Technical requirements
QB1965--1994
Appendix B
Wick band of olive lamp
(reference)
Basic parameters of olive lamp wick band shall comply with the provisions of Table B1. Table B1
Additional notes:
Branch/strand
Branch/strand
This standard is proposed by the Quality Standards Department of the Ministry of Light Industry. Weft
Branch/strand
Basic parameters
Shuttle/25.4mm
This standard is under the jurisdiction of the National Daily Hardware Standardization Center. This standard was drafted by Shanghai Olive Lamp Factory, Yangzhou Lamp Factory and Wuhu Gun Lamp Factory. ±2
Width, mm
Basic parameters
Thickness, mm
Basic parameters
The main drafters of this standard are Zhang Zishuo and Shen Jun. From the date of implementation of this standard, the professional standard ZBY73027-1989 "Olive Lantern" issued by the former Ministry of Light Industry will be invalid. 474Less than 5m
No more than 3,
distance more than 20mm
B1 Material
100% cotton yarn.
B2 Technical requirements
QB1965--1994
Appendix B
Olive lamp wick tape
(reference)
Basic parameters of olive lamp wick tape shall comply with the provisions of Table B1. Table B1
Additional notes:
Branch/strand
Branch/strand
This standard is proposed by the Quality Standards Department of the Ministry of Light Industry. Weft
Branch/strand
Basic parameters
Shuttle/25.4mm
This standard is under the jurisdiction of the National Daily Hardware Standardization Center. This standard was drafted by Shanghai Olive Lamp Factory, Yangzhou Lamp Factory and Wuhu Gun Lamp Factory. ±2
Width, mm
Basic parameters
Thickness, mm
Basic parameters
The main drafters of this standard are Zhang Zishuo and Shen Jun. From the date of implementation of this standard, the professional standard ZBY73027-1989 Olive Lamp issued by the former Ministry of Light Industry will be invalid. 474Less than 5m
No more than 3,
distance more than 20mm
B1 Material
100% cotton yarn.
B2 Technical requirements
QB1965--1994
Appendix B
Olive lamp wick tape
(reference)
Basic parameters of olive lamp wick tape shall comply with the provisions of Table B1. Table B1
Additional notes:
Branch/strand
Branch/strand
This standard is proposed by the Quality Standards Department of the Ministry of Light Industry. Weft
Branch/strand
Basic parameters
Shuttle/25.4mm
This standard is under the jurisdiction of the National Daily Hardware Standardization Center. This standard was drafted by Shanghai Olive Lamp Factory, Yangzhou Lamp Factory and Wuhu Gun Lamp Factory. ±2
Width, mm
Basic parameters
Thickness, mm
Basic parameters
The main drafters of this standard are Zhang Zishuo and Shen Jun. From the date of implementation of this standard, the professional standard ZBY73027-1989 Olive Lamp issued by the former Ministry of Light Industry will be invalid. 474
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.