title>GB/T 11313.1-2000 Radio frequency connectors Part 1-1: Single or multiple series blank detail specifications - GB/T 11313.1-2000 - Chinese standardNet - bzxz.net
Home > GB > GB/T 11313.1-2000 Radio frequency connectors Part 1-1: Single or multiple series blank detail specifications
GB/T 11313.1-2000 Radio frequency connectors Part 1-1: Single or multiple series blank detail specifications
Basic Information
Standard ID:
GB/T 11313.1-2000
Standard Name: Radio frequency connectors Part 1-1: Single or multiple series blank detail specifications
Standard ICS number:Telecommunications, audio and video technology>>Parts and accessories for telecommunications equipment>>33.120.30 Radio frequency connectors
Standard Classification Number:Electronic Components & Information Technology >> Electronic Components >> L23 Connector
associated standards
Procurement status:idt IEC 61169-1-1:1996
Publication information
publishing house:China Standards Press
ISBN:155066.1-17612
Publication date:2004-04-09
other information
Release date:2000-12-11
Review date:2004-10-14
Drafting unit:Electronic Industry Standardization Institute of the Ministry of Information Industry
Focal point unit:National Technical Committee for Standardization of High Frequency Cables and Connectors for Electronic Equipment
Publishing department:State Administration of Quality and Technical Supervision
competent authority:Ministry of Information Industry (Electronics)
This standard is equivalent to IEC 61169-1-1:1996 "RF connectors Part 1-1: Single or multiple series bilingual blank detailed specifications". Since IEC is an international standard, the text is in two languages. When this standard is used to formulate Chinese standards, only Chinese is used, so this article removes the "bilingual" in the original title. my country has formulated GB/T 11313-1996 "RF connectors Part 1: General requirements and test methods for general specifications" equivalent to IEC 61169-1:1992 (QC 220000). This standard is the blank detailed specification of the general specification. GB/T 11313.1-2000 RF connectors Part 1-1: Single or multiple series blank detailed specifications GB/T11313.1-2000 Standard download decompression password: www.bzxz.net
Some standard content:
GB/T11313.1—2000 This standard is equivalent to IEC61169-1-1:1996 "RF connectors Part 1-1, single or multiple series bilingual blank detailed specifications". Since EC is an international standard, the text is in bilingual. When this standard is used to formulate Chinese standards, only Chinese is used, so this article removes the "bilingual" in the original title. my country has formulated GB/T11313—1996 "RF connectors Part 1: General requirements and test methods" equivalent to EC61169-1:1992 (QC220000). This standard is the blank detailed specification of the general specification. General specification This standard is proposed by the Ministry of Information Industry of the People's Republic of China. This standard is under the jurisdiction of the National Technical Committee for Standardization of High-frequency Cables and Connectors for Electronic Equipment. The drafting unit of this standard: Electronic Industry Standardization Institute of the Ministry of Information Industry. The main drafters of this standard: Wu Zhengping and Li Mingde. GB/T11313.1—2000 IEC Foreword 1) IEC (International Electrotechnical Commission) is a worldwide standardization organization composed of national electrotechnical committees (IEC National Committees). The purpose of IEC is to promote international cooperation on standardization issues in the field of electrical and electronic engineering. For this purpose, among other activities, IEC publishes international standards. The formulation of international standards is undertaken by technical committees, and any EC National Committee concerned with the content involved can participate in the formulation of international standards. Any international, governmental and non-governmental organization associated with IEC can also participate in the formulation of international standards. IEC and ISO (International Organization for Standardization) maintain close cooperation under the conditions agreed upon by the two organizations. 2) IEC's formal resolutions or agreements on technical issues are formulated by technical committees participated in by national committees with special concerns about these issues, and represent the international consensus on the issues involved as much as possible. 3) These resolutions or agreements are used internationally in the form of recommended standards and are recognized by national committees in this sense. 4) In order to promote international unification, EC hopes that national committees will adopt EC standard texts as their national standards if conditions permit in their own countries. Differences between IEC standards and corresponding national standards should, as far as possible, be indicated in the national standards. 5) IEC has not established any procedures for the use of the approval mark and IEC assumes no responsibility when a product is declared to conform to the corresponding IEC standard. 6) It should be noted that some parts of this international standard may be the subject of patent rights. EC does not assume any responsibility for any or all of these patent rights identified. International Standard IEC 61169-1-1 was prepared by IEC Technical Committee 46 (Cables, wires, waveguides, connectors and accessories for communication equipment and signals) and Subcommittee 46D (Radio Frequency Connectors). The text of this standard is based on the following documents FDIS 46D/216/FDIS Voting Report 46D/233/RVD Voting Details of the approval of this standard can be found in the voting reports listed in the table above. This standard is to be used in conjunction with EC 61169-1:1992QC220000. GB/T11313.1—2000 IECQ specification system for radio frequency connectors General specification Quality assessment procedure Test and test methods "Special measurement procedure Reflection coefficient —Rated power —Shielding effectiveness General blank detailed specification for class M and class H Guide for the preparation of detailed specifications Sectional specification (SS) Drawings—standard test connectors, General connectors and applicable specifications for mating surface drawings—standard conditions for testing Identification and approval test Subsequent approval test |Cyclic test Detailed specification (S) Description of the product Specifications of specifications, applicable cables, etc. Appearance drawing Evaluation level Rated values (including use and limit conditions) and characteristics Test requirements A detailed specification is a completed blank detailed specification Used when the detailed specification is determined by 461. Fill in the two-letter code specified by IS to identify the NA1 that originally proposed the proposal, IECQ specification example QC221c01 IFC 6:169-1-1 QC221000 IFC 61169-19 BNC type 221C01601 *See note Normative procedure QC220000 1LC 61169-1 Special procedure Under consideration CK:221100 IEC: 61165 11 221001-504 22[001-002 Main NAI agent determination QQ221200 1x61159-12 221001-003 *See note 221001-005 +SC4.SD formulated National Standard of the People's Republic of China Radio-frequency connectors Part 1-1: Single, multi-series blank detail specification Radio-frequency connectors Part 1-1: Single, multi-series blank detail specification GB/T11313.1—2000 idtIEC 61169-1-1:1996 Instructions and Guidelines for Preparing Detail Specifications for Radio Frequency Connectors under the IECQ SystemEnter the following information in the corresponding positions in the Blank Detail Specification (BDS) box:Identification of Detail Specification (1) National body authorized to publish the detail specification and, when available, the body from which the detail specification can be purchased. (2) IECQ symbol and number of the detail specification assigned by the IECQ General Secretariat. (3) IECQ number and version of the general specification and section specifications, and national standard number (if different). (4) If different from the ECQ number, the national number of the detail specification, the date of publication and any further information required by the national system and any changes theretoEnter the connector series name in characters approximately 9 mm high in the ECQ Text Type box.Identification of Components (5) Enter the following information: Variety: The connector variety name or model. Cable/wire connection Method of connection to center conductor and outer conductor: Remove if not suitable. Features and markings: For example: Suitable for sealing of panels and insulation. Mass, maximum mass in nominal units, rounded up to the nearest whole number. If multiple specifications with different masses are included, the maximum mass of each specification should be listed separately. (6) Fill in the quality assessment level, characteristic impedance and climate category. (7) Fill in the outline drawing and panel opening details, indicating the maximum outer dimensions of the relevant shell variety and, for fixed connectors, the position relative to the front mounting panel of the connector. The interface dimensions, the relevant documents applicable to the outer dimensions (see the sectional specifications) and, for fixed mounting connectors, the maximum panel thickness should be given. The first or third quadrant projection can be represented by symbols by deleting the unsuitable graphics: First Quadrant Third Quadrant (8) Summary of all specifications included in the detailed specification. Where applicable, the following should be included: - Applicable cable types (or specifications) for each specification; - Alternative coatings or protective layers Alternative mounting flanges (mounting holes are threaded holes or through holes) Details: Approved by the State Administration for Quality Supervision, Inspection and Quarantine on December 11, 2000 and implemented on June 1, 2001 GB/T11313.1-2000 - Details of alternative soldering posts or soldering grooves for microwave component mounting types; (9) List the most important characteristic data of the connector according to the requirements of 3.1 of the sub-specification. Clearly indicate the minimum required deviations listed. Inapplicable parameters should be marked with "na". (10) Fill in the applicable content (11) Refer to the test grouping and test list in 3.3 of the relevant sub-specification, and fill in the letter "a" in "Required Tests" for those mandatory tests in the quality assessment level. In any additional tests required, it is up to the specification developer to determine whether the letter "a" should also be entered. In the "Number of Samples" column, the number of samples should be as specified in 3.3 Fill in the number of applicable quality assessment levels. The contents of (5) and (6) given in the detailed specification should be suitable for entry into IECQC001004 (Specification Catalog) or IECQC001005 (QPL). Each page should be marked with the version number of the detailed specification as required. When all contents are filled in, these descriptive contents will no longer appear in the complete detailed specification. *IECQC001004: Specification Catalog. **IECQC001005: IECQ system, including the catalog of companies, products and services approved by ISO9000. 2 Page 1/ (3)Quality assessment of electronic components according to: GB/T11313.1—2000 (2)QC22_ General specification: GB/T11313 (idtIEC61169-1QC220000) Sub-specification: GB/T Version_ (idt IEC 61169- (5) Detailed specification of RF connectors with quality assessment Variety: Features and markings: Cable/wire*Connection method Center conductor Solder* Crimp* Push-in lock* Clamp" *Only fill in the applicable content. (6) Assessment level (7) Appearance and maximum dimensions Appearance dimensions comply with Outer conductor Solder* Crimp* QC22__) Push-in lock* Clamp" Climate category_// Mating interface dimensions and reference surface see: GB/T Maximum panel thickness: Front installation: Characteristic impedance_ Panel opening dimensions and installation details Requirements; (IEC60169) mm; Rear installation: (8) Specifications Specification number GB/ T11313.1-—2000 Specification GB/T14864* or IEC60096** *GB/T14864 (eqvIEC60096-2) solid polyethylene insulated RF cable**EC60096: RF cable matching cable (9) Performance (including extreme conditions of use) rated values and characteristics Electrical performance Specification number Characteristic impedance||tt ||Reflection coefficient Center contact resistance2) Outer conductor resistance Center conductor continuity Outer conductor and shield Continuity Center conductor and outer conductor Continuity under severe mechanical conditions Insulation resistance Withstand voltage (at sea level)3) Withstand voltage (4.4kPa)8) Steady-state damp heat3) -01- - GB/T11313.1—2000 Test method GB/T11313—1996 (IEC61169-1 QC220000) Clause number -01- - -01- - -01 - - -01- - -01- - -- m2 -.-- -- mO There should be no instantaneous interruption phenomenon ≥_-us ---- kv Remarks or differences from standard Test method Frequency range Initial value After condition test Initial value After condition test Initial value After condition test Initial value After condition test Initial value After condition test 86kPa~106kPa -—kPaIf is4.4kPa) 86kPa~106kPa Rated values and characteristics Climate sequence3) Submerged test8 Shielding efficiency8) -01- - -01- - -01- - Discharge test (corona) (sea level) -01 - - Discharge test (corona) (4.4kPa) -01- - Additional electrical properties Mechanical properties Standard gauge retention force (elastic contact -center contact -outer contact center contact fixity -axial force and permanent displacement in each direction allowed Engagement force and separation force GB/T11313.1—2000 Test method GB/T11313—1996 (IEC61169-1 QC220000) Clause number Withstand voltage insulation resistance -V --_MQ _V--_MQ ≥_ dB at _ GHz ≥_ dB at _ GHz ≥_ dB At _ GHz ≥_ dB At _ GHz Extinction voltage Extinction voltage -N-_mm Remarks or differences from standard test method kPa (if not is 4.4kPa) Z<_-mo Z<_-m2 86kPa~106kPa _kPa (if not is 4.4kPa) Standard See the sub-specification for regulations Rated values and characteristics 1 Threaded connection Connection torque: —Overcoming friction —Normal situation —Test 2 Bayonet connection —Axial force —Torque 3 Lock connection —Engaging force —Separation force 4 Other connectionswww.bzxz.net Note: Not applicable to forced separation connection types. Clamping device effect 1 Cable rotation (deflection) 2 Cable stretching 3 Cable bending 4 Cable torsion -01- - -01- - GB/T11313.1—2000 Test method GB/T11313—1996 (IEC 61169-1 QC220000) Clause number --_Nmmax --- _Nm-Nm ≤_-_Nmin - - - _Nm min - - -.N min Torque time Remarks or differences from standard Test method Minimum bending of cable Cable length Cable length Ratings and characteristics Strength of connection Bending moment Additional mechanical characteristics Environmental properties Welding-welding head size Climate category Sealed-non-hermetic connector Sealed-hermetic connector Sand and dust (under consideration) Sulfur dioxide Additional environmental characteristics Durability Mechanical durability High temperature durability Other durability Resistance to solvents and contaminated fluids -Applicable liquids GB/T11313.1——2000 Test method GB/T11313—1996 (IEC61169-1 QC220000) Clause number m/s2ms -_cm\/hmax - - _ cm/h max ——_cycles —————days ——times Temperature time -_℃-_h Remarks or differences from standard test method Relative to reference surface (-g acceleration) (-ga acceleration) (=g acceleration) Pressure difference is 100kPa~ 110kPa Pressure difference is 100kPa~ 110kPa 1) These values are for connectors. In practice, they may be affected by the cables used. The cable specifications should be referred to. 2) Values for a pair of connectors. 3) Unless otherwise specified, the voltage values are AC effective voltage values of 40Hz to 65Hz. (10) Supplementary content GB/T11313.1—2000 Component marking: in accordance with the provisions of 11.1 of GB/T11313—1996 (idtIEC61169-1QC220000), and in the following order 1) Manufacturer's identification code: 2) Manufacturing date code 3) Component marking code Year/week Specification number/model Marking and contents of packaging: in accordance with the provisions of 11.2 of GB/T11313—1996 (idtIEC61169-1QC220000). 1) Mark the above content in detail as specified in 11.1 of GB/T11313-1996 2) Nominal impedance 3) Evaluation level code letter 4) Any required additional marking Ordering information: Specify the following content in accordance with the relevant provisions of GB/T11313-1996 (idtIEC61169-1QC220000): 1) Detailed specification number 2) Quality assessment code letter 3) Shell Coating (if more than listed) 4) Any additional content or special requirements /Specification code Related documents (if not included in GB/T11313-1996 (idtIEC61169-1QC220000) or sub-specifications): Structural similarity is in accordance with 22.2 of GB/T11313-1996 (idtIEC61169-1QC220000) Note: 01 is the specification number of the relevant basic variety. 9 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.