Pharmaceutical Industry Standard of the People's Republic of China YY 0080-92 Carbide Insert Needle Holders Issued on 1992-01-20 Issued by the State Food and Drug Administration Implemented on 1992-07-01 Pharmaceutical Industry Standard of the People's Republic of China Carbide Insert Needle Holders 1 Subject and Scope of Application YY0080-92 This standard specifies the production requirements for carbide insert needle holders. The needle holding pin marked with suitable size is made of hard metal. The product is used for clamping suture chains or weaving. 2 Reference standards GB3r64 Egg-shaped drawing GB2765 Chain stop GB3054 Glass pliers for surgical instruments GBS05E GB11229 General technical conditions for needle holders 3 Product classification 3-1 The type and size of the pin shall be in accordance with the provisions of the table: Table 3.2 The basic dimensions of the needle shall be in accordance with the provisions of Table 1--Figure 6 and Table 2. Guohao Pharmaceutical Xiangli Gao 1992-1-20 approved no worry needle period 1992-07-01 implementation YY C030-92 Figure 1 fine pin Figure 2 no worry needle forceps YV 0089 -92 Figure 3 fine needle effective curved forceps YY0080-92 AA monitoring film Figure 5 paper design special negative forceps YY 0080-92bzxZ.net Figure 5 fine needle hundred angle forceps hundred energy type anti-rice requirements 7.4 bias pad = 6 24 7. 0 14 2x2 --..- h3e 41 When the machine is fully engaged, the needle locking force is 40N and the damage is not 130. 4.2 The pin should have good closing performance, and the length of the micro-piece before and after the force (.5-1).1m should be limited. YY0080-92 4.3 The pliers and the insert are connected in the same way. After the elasticity and semi-usability test, the abdominal piece does not fall off or crack. 4.4 The mystery medicine, H ruler, the danger monitoring time sequence is checked item by item. 4.5 The other technical requirements, test methods, inspection specifications, packaging, transportation and storage of the pliers should comply with the provisions of CB1122911. Additional remarks This standard is proposed by the National Scientific Instrument Standardization Technical Committee. This standard is under the jurisdiction of Shanghai Medical Device Testing Center. This standard was drafted by Shanghai Surgical Devices Testing Center. The main drafter of this standard is Huang Mengrui. Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.