Basic Information

Standard ID: JG/T 3015.1-1994

Standard Name: Sliding automatic door JG/T3015.1-94

Chinese Name: 推拉自动门JG/T3015.1-94

Standard category:Construction industry industry standards (JG)

state:Abolished

Date of Release1994-04-20

Date of Implementation:1994-12-01

Date of Expiration:2005-12-01

standard classification number

Standard Classification Number:Building Materials>>Building Components and Equipment>>Q73 Metal Components

associated standards

alternative situation:Replaced by JG/T 177-2005

Publication information

other information

Introduction to standards:

JG/T 3015.1-1994 Sliding automatic door JG/T3015.1-94 JG/T3015.1-1994 Standard download decompression password: www.bzxz.net

Some standard content:

The People's Republic of China Construction Industry Standard for Automatic Doors
JG/T3015.1—94
Approved by the Ministry of Construction of the People's Republic of China on April 20, 1994 and implemented on December 1, 1994
1 Content and applicable scope
This standard specifies the product classification, technical requirements, test methods, inspection rules and marking, packaging, transportation and storage of automatic sliding doors.
This standard applies to sliding doors that automatically open and close at the exit of buildings, namely automatic sliding doors (hereinafter referred to as doors), code-named TDM. Arc automatic sliding doors can also be used for reference, code-named YTDM. 2 Applicable standards
GB191 Packaging storage and remote control graphic marking
GB24231 Basic environmental test procedures for electric and electronic products Test A: Low temperature test method GB2423.2 Basic environmental test procedures for electric and electronic products Test B: High temperature test method
GB2423.3 Basic environmental test procedures for electric and electronic products Test Ca: Steady condensation test method GB3797 Electric control equipment Part 2: Electric control equipment equipped with electronic components GB4706.1 General safety requirements for household and similar electrical appliances GB5237
GB5824
GB6388
3 Product classification
Aluminum alloy building profiles
Building door and window opening size series
Transport packaging delivery and receipt marks
3.1 Basic dimensions of door thickness:
3.1.1 The basic dimensions of door thickness are distinguished by the thickness and structural dimensions of the door frame, see Table 1. mr
Basic door thickness series
3.1.2 Door thickness series not listed, within ±2mm relative to the basic series, can be close to the basic series. 3.2 Door opening series:
3.2.1 The width and height of the door are mainly determined according to the installation requirements of the opening. 3.2.2 The specifications of the basic door opening are shown in Table 2. 2
Ram, mm
Opening width,
3.2.3 Except as specified in Table 2, any combination of doors is allowed, and the opening size after combination shall comply with the provisions of GB5824.
3.3 Basic facade types of doors:
a) Single-leaf door;
b) Single-leaf door with upper light;
c) Double-leaf door;
d) Double-leaf door with upper light.
Note: ①The above definitions of single-leaf and double-leaf refer to moving leaves, and their basic facade types are shown in Table 3. ②Other types of doors can be designed and manufactured according to user requirements. ③Single-leaf doors can be opened to the right or left. ④Double-leaf doors are moving leaves that open to both sides. 3.4The basic dimensions of door leaf height are divided into two series: 2100 and 2400mm. 3.5The weight of a single door leaf is divided into three levels: 45, 75, and 125kg. 3.6Differentiation by door leaf structure:Www.bzxZ.net
a) Framed door, code Y;
b) Frameless door, code W.
3.7 According to the detection device:
a) Microwave detector, code B;
b) Infrared detector, code H;
c) Ultrasonic detector, code C;
d) Electromagnetic induction detector, code D; e) Special detector, code T.
Swish width,
4 Technical requirements
4.1 Materials
4.1.1 The door body material adopts aluminum alloy building profiles, and other materials can also be used. 4.1.2 The aluminum alloy building profiles used for doors shall comply with the provisions of GB5237, and other materials and accessories shall comply with the current national standards and industry standards.
4.1.3 The door and the selected parts and accessories, except stainless steel or corrosion-resistant materials, shall be treated with rust and corrosion prevention, and contact corrosion with aluminum alloy profiles is not allowed. 4.2 Assembly requirements
4.2.1 The dimensional deviation of the door frame made of profiles shall comply with the requirements of Table 4. mm
Inner width and height of door frame allowable
Inner opposite side dimensions of door frame
Inner diagonal dimensions of door frame
≤2000
Superior products
First-class products
Qualified products
The assembly clearance and flatness of adjacent components of door frames and sashes made of profiles shall comply with the requirements of Table 5. mm
Flatness
Superior
First-class
Qualified
Assembly clearance
Superior
First-class
Qualified
4.2.3 The door components should be firmly connected, and the structure should have sufficient strength and rigidity to withstand the installation of drive, control and other parts and components and ensure that the door can be opened and closed freely.
4.2.4 The horizontality of the door beam guide rail shall not exceed 1mm per meter of length. 4.2.5 The verticality of the door frame shall not exceed 1mm per meter of length. 4.2.6
The vertical plane where the lower guide rail and the door beam guide rail are located shall be parallel, and the parallelism shall not exceed 1mm per meter of length. The clearance between the door frame and the leaf should be uniform. When fully closed, the limit deviation of the clearance between the moving leaf and the frame or the vertical edge of the fixed leaf should not exceed ±1.5mm, and the limit deviation of the clearance between the leaves should not exceed ±1.5mm. 4.2.8 During operation, the moving leaf shall not scrape or rub against the door beam cover, fixed leaf and the ground. 4.2.9 The installation of door parts and accessories should be correct, complete and firm, play their respective roles, have sufficient strength and be flexible to open and close.
4.3 Surface quality
4.3.1 The decorative surface of the door should not have obvious damage and defects that affect performance. The local scratches and scratches of each door should comply with the relevant standards or relevant standards.
4.3.2 There should be no obvious color difference between the colored surfaces of adjacent components of the door. 4.3.3 There should be no metal shavings, burrs, corrosion marks and other stains on the door surface. 4.4 Performance of the door
4.4.1 The power supply voltage for the door should be AC220V±10%, and the frequency should be 50Hz. 4.4.2 The detection range of ultrasonic, infrared and microwave detectors shall be adjustable, and their detection area shall meet the requirements of Table 6. m2 Table 6
Detection device type
Ultrasonic detector
Detection area
Detection device type
Infrared detector
Detection area
Detection device type
Microwave detector
4.4.3 The detector shall be installed to ensure that the distance between the edge of its blind area and the door is no more than 200mm. Detection area
4.4.4 The door shall be sensitive to opening and closing. When a person or object passes through the detection range at a speed of 0.3m/s, it shall open and close normally. 4.4.5 During the opening and closing process of the door, the fast running speed shall be 0.2~0.4m/s. 4.4.6 Before fully opening or fully closing, the speed of the door shall be reduced to a safe and reliable slow speed, and shall be adjustable, with obvious buffering and smooth opening and closing.
The response time of door opening shall not exceed 0.5s. 4.4.8 The delay of door blocking protection shall not exceed 18s. 4.4.9 The holding time after the door leaf is fully opened shall not exceed 1.5s. 4.4.10
The operating noise of the door under normal working condition shall not exceed 65dB. When the power supply of the door is cut off, the manual push and pull force shall not exceed 50N. When the mass of the door moving leaf is greater than 100kg, the push and pull force shall not exceed 5% of the mass of the door leaf. 4.4.12 Under hot and humid conditions, the insulation resistance shall not be less than 2MQ. 4.4.13
The live main circuit of the door and the metal casing shall be able to withstand AC1500V without breakdown within 1min. The door shall be able to work normally under the condition of an ambient working environment temperature of -10~15℃. 4.4.141
The door should be able to work normally under the condition of ambient working temperature of 40℃ and maximum relative humidity of 80%. Under normal working conditions, the working life of the door shall not be less than 500,000 times. 4.4.16
Wind resistance of the door: It should be able to work normally under the condition of wind speed of 0~10m/s. 4.4.17
5 Test method
5.1 Inspection of the contents of Article 4.1
Use visual inspection method to inspect.
5.2 Inspection of the contents of Articles 4.2 and 4.3
Use special instruments such as steel tape measure, feeler gauge, caliper, level gauge and visual inspection and hand feeling methods to inspect. 5.3 Inspection of the contents of Article 4.4.1
Use voltage regulator to adjust the power supply voltage and use multimeter voltage range to inspect. 5.4 Test for 4.4.2~4.4.4
A person with a height of 1.5m or more shall enter the specified detection range at a speed of 0.3m/s, observe whether the door leaf can be opened and whether the movement is good, and measure the distance between the edge of the detection area and the door. 5.5 Test for 4.4.5. Test for content
The tested door is in normal working state. Use a steel tape measure to measure the distance of the moving fan from starting to the fast running distance before buffering. Use a 949
timer to record the time, and then calculate its speed. Test for 3 times in a row and take the average value. 5.6. Test for content 4.4.6
Put the tested door body in working state, start the control system, make the moving fan fully open and fully closed, and observe whether the door leaf runs smoothly for 3 times in a row.
5.7. Test for content 4.4.7
Put the door body in normal working state in the closed position. Start with a stationary human body in the detection area. Observe and use a timer to record the time from the human body moving to the door moving fan starting. Test for 3 times in a row and take the average value. 5.8. Test for content 4.4.8
Use a timer to record the time from the moving fan contacting the person blocking the center of the door entrance and exit to the door automatically stopping the closing action during the automatic closing process. Test for 3 times in a row and take the average value. 5.9 Test for 4.4.9
Use a timer to record the time from the disappearance of the detector signal to the start of the door closing during the automatic opening and closing of the moving leaf. Test three times in a row and take the average value.
5.10 Test for 4.4.10
Under the condition that the ambient noise is not more than 45dB, use a sound level meter to measure the noise of the door in normal working state at a distance of 1.0m before and after the center of the door and a height of 1.5m. Measure three times in a row and take the average value. 5.11 Test for 4.4.11
Cut off the power supply, fix the dynamometer in the middle of the moving leaf, and slowly apply a horizontal force parallel to the plane of the door leaf to open or close the moving leaf of the door, record the maximum force value on the dynamometer, test three times in a row and take the average value. 5.12 Test for 4.4.12
Perform the test according to the test method specified in GB4706.1. 5.13 Test for 4.4.13
Perform the test in accordance with the test method specified in 4.4 of GB3797. 5.14 Test for 4.4.14
Perform the test in accordance with the test method specified in GB2423.1 Test Ab and GB2423.2 Test Bb to check whether the test piece has any damage on the appearance and whether it can work normally.
5.15 Test for 4.4.15
Perform the test in accordance with the test method specified in GB2423.3 Test Ca, with the test severity level of 2d, to check whether the test piece has any damage on the appearance and whether it can work normally.
5.16 Test for 4.4.16
Start the control button, open and close once in a cycle of 10 to 30 seconds, and run back and forth continuously for 500,000 times. Secondary wearing parts can be replaced during the whole process.
5.17 Test for the content of Article 4.4.17
Put the door leaf in the open or closed state, supply air at a wind speed of 10m/s along the vertical direction of the door, open and close the door 3 times, and check whether there are any abnormalities in the state and movement of the door. 6 Inspection rules
6.1 Factory inspection
6.1.1 Before leaving the factory, the product must be inspected and qualified by the quality inspection department of the manufacturer, and the certificate of conformity must be issued before it can leave the factory. 950
6.1.2 Factory inspection items
Inspect in accordance with the contents and requirements specified in Articles 4.1~~4.3 and 4.4.2~4.4.12 of this standard. 6.1.3 Sampling method and judgment rules
Sampling of each project shall not be less than 50%, but the number of sampling shall not be less than two. If all inspection items are qualified, it is qualified. When one of the items is unqualified, a random inspection shall be conducted. If the item is still unqualified, the batch shall be judged as unqualified. All unqualified products shall be repaired and delivered only after re-inspection. 6.2 Type inspection
6.2.1 Type inspection shall be conducted in any of the following situations. a) Trial design and identification of new products or old products for production; b) After normal production, if there are major changes in structure, materials, and processes, which may affect product performance; c) During normal production, continuous production for more than 5 years; d) When production is resumed after suspension for more than one year; e) When the national quality supervision agency proposes a requirement for type inspection. 6.2.2 Type inspection items
Tests shall be conducted in accordance with the contents and requirements specified in Chapter 4 of this standard. 6.2.3 Sampling method and judgment rules
Three products shall be sampled from qualified products for type testing. If all inspection items are qualified, it is qualified. When one of the items is unqualified, double sampling shall be conducted. If the item is still unqualified, the batch shall be judged as unqualified. Unqualified products are allowed to be returned for re-inspection.
7 Marking, packaging, transportation and storage
7.1 Marking
7.1.1 There shall be a nameplate in a conspicuous part of the product, which shall indicate: a) Trademark and manufacturer name
b) Product name;
e) Product model;
d) Manufacturing date or number.
7.1.2 The marking on the packaging box shall comply with the provisions of GB6388. 7.1.3 The packaging box should have words and signs such as "moisture-proof", "handle with care" and "upward", and the graphics should comply with the provisions of GB191.
7.2 Packaging
7.2.1 Products should be packaged with non-corrosive materials. 7.2.2 The packaging box should have sufficient strength and moisture-proof measures. 7.2.3 Products packed in the box should be guaranteed not to move with each other. 7.2.4 After the product is packed, there must be a packing list, product certificate, product instruction manual and warranty card. 7.3 Transportation
7.3.1 The transportation vehicle should have rain protection measures and be kept clean and free of dirt. 7.3.2 Products are strictly prohibited from falling or colliding during transportation and loading and unloading. The geometric shape of the product should remain unchanged and the surface should be intact. 7. 4 Storage
7.4.1 The product should be placed in a ventilated and dry place. It is strictly forbidden to contact with acids, alkalis, and salt substances, and prevent rain from soaking people. 7.4.2 The product cannot directly contact the ground, and the bottom should be raised by more than 100mm. Additional instructions:
This standard is proposed by the Standard and Quota Research Institute of the Ministry of Construction. This standard is managed by the China Building Standard Design Institute, the technical management unit for standardization of building products and equipment. This standard was prepared by the China Building Metal Structure Association (the main drafting unit), Shenyang Liming Aluminum Doors and Windows Engineering Company, Shandong Tengzhou Steel Window Factory, and Ningbo Automatic Door Factory. The main drafters of this standard are Cui Yongfeng, Li Jinfeng, Jin Shunxing, Liang Quanshun, Jing Chuandi, and Lin Wanjiong. This standard is entrusted to the China Building Standard Design Institute for interpretation. 95216 Tests
Start the control button, open and close once in a cycle of 10 to 30 seconds, and run back and forth 500,000 times continuously. Secondary wearing parts can be replaced during the whole process.
5.17 Test of 4.4.17
Put the door leaf in the open or closed state, send air at a wind speed of 10m/s along the vertical direction of the door, open and close the door 3 times, and check whether there are any abnormalities in the state and movement of the door. 6 Inspection rules
6.1 Factory inspection
6.1.1 Before leaving the factory, the product must be inspected and qualified by the quality inspection department of the manufacturer, and the certificate of conformity must be issued before it can leave the factory. 950
6.1.2 Factory inspection items
Inspect in accordance with the contents and requirements specified in Articles 4.1~~4.3 and 4.4.2~4.4.12 of this standard. 6.1.3 Sampling method and judgment rules
Each project shall be sampled for no less than 50%, but the number of sampling shall not be less than two. If all the inspection items are qualified, it is qualified. When one of them is unqualified, additional sampling should be conducted. If the item is still unqualified, the batch shall be judged as unqualified. All unqualified products shall be repaired and delivered only after re-inspection. 6.2 Type inspection
6.2.1 Type inspection shall be carried out in any of the following situations. a) Trial determination and identification of new products or old products for production; b) After normal production, if there are major changes in structure, materials, and processes, which may affect product performance; c) During normal production, continuous production for more than 5 years; d) When production is resumed after suspension for more than one year; e) When the national quality supervision agency proposes a requirement for type inspection. 6.2.2 Type inspection items
Tests shall be carried out in accordance with the contents and requirements specified in Chapter 4 of this standard. 6.2.3 Sampling method and judgment rules
3 samples are randomly selected from qualified products for type test. If all the inspection items are qualified, the batch is qualified. If one of them is unqualified, double sampling should be carried out. If the item is still unqualified, the batch is judged to be unqualified. Unqualified products are allowed to be returned for re-inspection.
7 Marking, packaging, transportation and storage
7.1 Marking
7.1.1 There should be a nameplate in a conspicuous part of the product, which should indicate: a) Trademark and manufacturer name
b) Product name;
e) Product model:
d) Manufacturing date or number.
7.1.2 The marking on the box surface of the packaging box should comply with the provisions of GB6388. 7.1.3 The packaging box should have words and signs such as "moisture-proof", "handle with care" and "upward", and the graphics should comply with the provisions of GB191.
7.2 Packaging
7.2.1 Products should be packaged with non-corrosive materials. 7.2.2 The packaging box should have sufficient strength and moisture-proof measures. 7.2.3 Products packed in the box should be guaranteed not to move with each other. 7.2.4 After the product is packed, there must be a packing list, product certificate, product instruction manual and warranty card. 7.3 Transportation
7.3.1 The transportation vehicle should have rain protection measures and be kept clean and free of dirt. 7.3.2 Products are strictly prohibited from falling or colliding during transportation and loading and unloading. The geometric shape of the product should remain unchanged and the surface should be intact. 7. 4 Storage
7.4.1 The product should be placed in a ventilated and dry place. It is strictly forbidden to contact with acids, alkalis, and salt substances, and prevent rain from soaking people. 7.4.2 The product cannot directly contact the ground, and the bottom should be raised by more than 100mm. Additional instructions:
This standard is proposed by the Standard and Quota Research Institute of the Ministry of Construction. This standard is managed by the China Building Standard Design Institute, the technical management unit for standardization of building products and equipment. This standard was prepared by the China Building Metal Structure Association (the main drafting unit), Shenyang Liming Aluminum Doors and Windows Engineering Company, Shandong Tengzhou Steel Window Factory, and Ningbo Automatic Door Factory. The main drafters of this standard are Cui Yongfeng, Li Jinfeng, Jin Shunxing, Liang Quanshun, Jing Chuandi, and Lin Wanjiong. This standard is entrusted to the China Building Standard Design Institute for interpretation. 95216 Tests
Start the control button, open and close once in a cycle of 10 to 30 seconds, and run back and forth 500,000 times continuously. Secondary wearing parts can be replaced during the whole process.
5.17 Test of 4.4.17
Put the door leaf in the open or closed state, send air at a wind speed of 10m/s along the vertical direction of the door, open and close the door 3 times, and check whether there are any abnormalities in the state and movement of the door. 6 Inspection rules
6.1 Factory inspection
6.1.1 Before leaving the factory, the product must be inspected and qualified by the quality inspection department of the manufacturer, and the certificate of conformity must be issued before it can leave the factory. 950
6.1.2 Factory inspection items
Inspect in accordance with the contents and requirements specified in Articles 4.1~~4.3 and 4.4.2~4.4.12 of this standard. 6.1.3 Sampling method and judgment rules
Each project shall be sampled for no less than 50%, but the number of sampling shall not be less than two. If all the inspection items are qualified, it is qualified. When one of them is unqualified, additional sampling should be conducted. If the item is still unqualified, the batch shall be judged as unqualified. All unqualified products shall be repaired and delivered only after re-inspection. 6.2 Type inspection
6.2.1 Type inspection shall be carried out in any of the following situations. a) Trial determination and identification of new products or old products for production; b) After normal production, if there are major changes in structure, materials, and processes, which may affect product performance; c) During normal production, continuous production for more than 5 years; d) When production is resumed after suspension for more than one year; e) When the national quality supervision agency proposes a requirement for type inspection. 6.2.2 Type inspection items
Tests shall be carried out in accordance with the contents and requirements specified in Chapter 4 of this standard. 6.2.3 Sampling method and judgment rules
3 samples are randomly selected from qualified products for type test. If all the inspection items are qualified, the batch is qualified. If one of them is unqualified, double sampling should be carried out. If the item is still unqualified, the batch is judged to be unqualified. Unqualified products are allowed to be returned for re-inspection.
7 Marking, packaging, transportation and storage
7.1 Marking
7.1.1 There should be a nameplate in a conspicuous part of the product, which should indicate: a) Trademark and manufacturer name
b) Product name;
e) Product model:
d) Manufacturing date or number.
7.1.2 The marking on the box surface of the packaging box should comply with the provisions of GB6388. 7.1.3 The packaging box should have words and signs such as "moisture-proof", "handle with care" and "upward", and the graphics should comply with the provisions of GB191.
7.2 Packaging
7.2.1 Products should be packaged with non-corrosive materials. 7.2.2 The packaging box should have sufficient strength and moisture-proof measures. 7.2.3 Products packed in the box should be guaranteed not to move with each other. 7.2.4 After the product is packed, there must be a packing list, product certificate, product instruction manual and warranty card. 7.3 Transportation
7.3.1 The transportation vehicle should have rain protection measures and be kept clean and free of dirt. 7.3.2 Products are strictly prohibited from falling or colliding during transportation and loading and unloading. The geometric shape of the product should remain unchanged and the surface should be intact. 7. 4 Storage
7.4.1 The product should be placed in a ventilated and dry place. It is strictly forbidden to contact with acids, alkalis, and salt substances, and prevent rain from soaking people. 7.4.2 The product cannot directly contact the ground, and the bottom should be raised by more than 100mm. Additional instructions:
This standard is proposed by the Standard and Quota Research Institute of the Ministry of Construction. This standard is managed by the China Building Standard Design Institute, the technical management unit for standardization of building products and equipment. This standard was prepared by the China Building Metal Structure Association (the main drafting unit), Shenyang Liming Aluminum Doors and Windows Engineering Company, Shandong Tengzhou Steel Window Factory, and Ningbo Automatic Door Factory. The main drafters of this standard are Cui Yongfeng, Li Jinfeng, Jin Shunxing, Liang Quanshun, Jing Chuandi, and Lin Wanjiong. This standard is entrusted to the China Building Standard Design Institute for interpretation. 952
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.