Mechanical Industry Standard of the People's Republic of China
JB/T9541
1999-08-06
Wa Xian Ji Dong
2000-01-01
JB/T95411999
This standard refers to the International Industry 1 Committee Standard IE60034.1, the American Electrical Manufacturers Association NMA Standard MG--198 Tenth Division Multiple Ratings "The United States delineation, this standard is ZBK20001--89 "Home This revised standard is based on the original standard and has added a new title, but the technical content remains unchanged. It only quotes the existing IE title, and also abolishes the existing IE title. It stipulates GB1.3, adds: "Specifications", "Citations of standards", "Parameters and sizes of specifications", and changes the first, second, and third chapters into sections, sixth, and seventh chapters. The content of chapters such as sources are included in the new chapter, and the arrangement of the duties and article numbers are also changed accordingly. The name of this standard is ZBK2U003-89. This standard is drafted by the Guangzhou Electric Power Research Institute. The main authors of this standard are: Wenhua, Wu Guoping, Su Pihua, Zhang Changchuang, and Shang Shuizun. This standard is fully interpreted according to the Small Power Motor Standardization Technical Committee of the Electric Motor Standardization Technical Committee. I
JB/T95411999
ZBK2000189
This standard is for single-material electric rotating ring motors and single-shell type motors (hereinafter referred to as motors) for ventilation fans of similar purpose
Cited standards
The following standards contain provisions that constitute the provisions of this standard unless explicitly used in this standard: At the time of publication of the standard, the versions shown are valid. All standards will be revised. The parties who use this standard should consider the possibility of using the latest version of the following standards. GB19:1990
However, the installation and storage diagrams
GBT2423.31993 Electric 1 Electric product environment test specifications Test C3: Constant condensation test method (IEC 60068--2--3: 1969)
G3 4706 11992
GB 4706.27-1992
Safety requirements for household power transmission groups (1603351: 1976) Safety requirements for household power conditioners (IDT #EC 60342-i: 1981)
Classification of external protection of motors (VH: 600345: 1983) CB.T 4942.1--1985
GB:T5171-1991
GBrT 9651--1988Www.bzxZ.net
Technical record of small power electric motor (601034-:1983) Single machine license plate less information test method
GBT10069.1~-1988 Rotating motor vibration determination method and limit value instantaneous determination method (e9v SQ 1680--[:1986)
13/[4269-1999
JB/F J480G--1993
3 Type and basic parameters
General technical conditions for motors
Frequency converters and speed regulators for micro-circuits: IEC 60665: 1980) 31 The protection level of the motor is [×, 11X, IP3X, 1F4X3.2 The rated power supply of the motor is 220V and the rated power is 50W. 33 The working mode of the motor is continuous duty (S1). 34 The rated output power (W) of the electric motor is as follows: 2.3, (3.0), 4.0, (5.0), 6.0, 8.0, 10.0. (12.5), 16.0. (200), 25.0, (300): 40.0, (500. 60.0 with (non-core,
shielded motor rated output power (W) should meet the frequency rating of B4269099 Article 1.4 35 electric passenger running motor speed is 0. Wa slow 1999-08-06 tumor
2000-01-01 small cable
JB/T9541
motor speed 3000, 150
motor should be installed with the old speed control station, the rated speed should be agreed upon by the supply and production parties, it is recommended that the electric motor should give priority to the following speeds: 900, 1100, 1300/nin
4 technical requirements
41 electric speed in accordance with the requirements of this standard, must be approved according to the prescribed procedures Standard drawings and documents: 4.2 Under the following environmental conditions, the motor should be able to operate over rated speed: a) The altitude is more than 1030m
The maximum power limit of the ambient air is 40°C
The average monthly maximum air temperature at the end of the ambient air is %, and the average monthly minimum temperature of the year is 25.
[The best electric motor specification is more than 100m. The ambient air temperature is higher than 4G, and the specification is based on G]. 2. The motor is rated for operation at rated power, rated rate and high speed. 4.3 The motor's power, current and rated rate are within the rated value. The efficiency, ratio and wind speed of the motor shall comply with the requirements of Table 1. The control efficiency of asynchronous motors shall meet the requirements of Table 2 of B42G9--1599 for rated power and load capacity:
According to the batch specification
Motor type
Capacitor-operated motor
According to JB/T9541
44 Under rated frequency and rated current, the locked-rotor torque guarantee value of the motor: Capacitor-operated motors shall meet the requirements of Table 3. The motors shall meet the requirements of Article 2.5 of JB4269-1999. Installation 3
Power number
Step speed/min
Power output
【20.0】
With short-circuit
4 At rated frequency Under the conditions of rated power and rated frequency, the guaranteed value of the motor's minimum torque during starting is as low as possible! The maximum torque guaranteed value of the motor under rated power and rated frequency is as follows: The capacitor-type motor should meet the requirements of Table 5 for the output power of the capacitor-type step-down motor and the output power of the capacitor-type step-down motor in J4269159926. Table 5 Power consumption data of the motor during starting should meet the requirements of Table 5: Table 5 Power consumption data of the motor during starting should meet the requirements of Table 5. Minimum speed of the motor during starting and the maximum speed of the motor during starting. cs1 is at most. ?
, which means that the cost exceeds 1000n, the small environment density does not exceed 409, in the test piece according to the provisions of 3.3 of the standard 4.% motor E or B grade insulation, the winding temperature should meet the requirements of Table 6. 5
measurement position
E grade insulation
9 also the leakage current of the motor batch is not more than 3A,
electric method
410 motor system can not send a history of the machine research! The withstand voltage test of the motor should be free of flashover or breakdown. The test power supply has a pass rate of 50H, the waveform is a real positive waveform, the discharge of the test equipment should be less than 0.75 VA, the test voltage (effective inductance) is 1500V. During the short-term test, the specified test voltage is used. The test lasts for 1s. The winding of the motor should be able to withstand the short-term rise-off voltage test and the insulation does not break. The test is carried out when the motor is unloaded. The voltage applied during the test is 130% of the specified value. The test time of the shaded pole motor is 3 hours. The lock rate is allowed to increase for a period of time. The required rate should not exceed 15%. The test time of the motor in operation is! mm, no commercial rate is allowed, 412 motor windings in hot state or after leakage test, its insulation resistance to the machine is not 2M94.13 motor after heat test should meet the following requirements: a) insulation resistance is not less than 2MQ;
h windings should be able to withstand the withstand voltage for 1min without flashover or run-through before the test, the test power frequency is 50Hz, the wave is an actual sine wave, the power of the test equipment is not less than 0.75kVA, the test voltage (effective value) is 1250V: the motor should be able to start at rated frequency and 80% rated voltage: a, b mixed heat test () within 4.14 When the capacitor-operated motor is under rated frequency and rated voltage, the terminal voltage of the capacitor shall not exceed the specified rated value of the capacitor during starting and running. 4.15 When the motor is subjected to the abnormal working test specified in Article 5.8 of this standard, the temperature of the system shall not exceed the values specified in Table 7. The protective device in Table 7 is used for starting protection. 16 During the test specified in Article 5.8 of this standard, the motor shall not emit flame or full flow of liquid, or exceed a certain amount of hazardous or flammable gas. 4.17 The A-weighted sound power level measured when the motor is no-load shall not exceed the value specified in Table 8. 8
Indole silver value [B (A
2 5 -(3.0)
10 ~(20)
25 ~ 60
Rolling auxiliary bearing
4.[8 The distance between the exposed part of the electric row and the electrical spacing shall not be reduced by the value specified in GB1706.1-1992 21: 4.19 The radial net runout of the motor energy rotating parts shall not be greater than 0.06m1m: 4.20 The motor can still operate under the condition of positive belt operation after 5000 continuous use. 4.21 The surface of the electric peach shall not have hunger points, bubbles, collisions, cracks and adhesion of dirt. 4.22 In use, follow the instructions of the manufacturer and use the electric peach correctly. Under these circumstances, the manufacturer shall ensure that the motor can stop running within the period of 1 year. The date of shipment shall not exceed the period of 1 year. If the motor is damaged due to poor maintenance or cannot work properly, the manufacturer shall repair or replace parts for the user free of charge.
5 Test method
51 The test method of the motor shall be carried out in accordance with the provisions of this standard and GBT9631. 52 The output power, efficiency and power rating shall be measured directly. Note: The motor shall be subjected to the direct measurement method. After running at a fixed angle for 10m, the S.3 surge test is carried out on the ventilation fan in accordance with the provisions of GB4706.1 and GB4706.27-1992 Chapter 11. The test density is the most unfavorable electrical sequence for the motor between 0.94% and 1.% of the rated voltage. 5.4 Discharge current measurement is carried out in accordance with the provisions of GB4706.1 and GB4706.27-1992 Chapter 13. The test voltage is 1.06% of the rated voltage. 5.5 Noise level is carried out in accordance with GB/T10069.1:
5.6 Heat reduction test is carried out in accordance with 5.7 The long-term operation test shall be carried out on the ventilation fan in accordance with the provisions of Article 6.13 of GB/T 814806-1993. 5.8 The non-positive belt test shall be carried out on the ventilation fan in accordance with the provisions of Chapter 19 of GB4706.1 and GB4706.27-1992. 5.9 The external protection grade test shall be carried out in accordance with the relevant provisions of GB/T 4942.1. 6 Inspection regulations
Each electric machine shall be subjected to inspection and test. The inspection and test are as follows:
6.1.1 Mechanical inspection:
a) Appearance quality inspection:
b) Check whether the motor is assembled completely and correctly: the motor should rotate smoothly and briskly without abnormality: d) Installation dimension inspection;
3) Inspection of radial runout.
(.1.2 Determination of the first current of the stator system under actual cold state. 6.1.3 Determination of the insulation resistance of the winding to the shell (the insulation resistance in the cold state can be measured during the inspection test, but the insulation resistance in the hot state should be no less than 2M
6.1.4 No-load test:
) Determination of no-load current power:
b) Reduce no-load running.
6.13 Determination of locked-rotor current loss.
6.1 specifies the battery test for the machine, and 6.17 specifies the voltage test.
Each product must be inspected according to clauses a, b, c and 6.1.3.6.1.4, 6.1.6, and 6.1.7. Other items may be changed continuously. The number of products sampled should not be less than 2% of each batch of products [not more than 3 sets in a group). If any unit fails any item during the product test, the number of products sampled should be doubled, and the test of the item should be carried out simultaneously. If any unit still fails, the item should be considered as unqualified. 62 Type test
JB/T9541
6.2! The following tests must be carried out for the following: a) the first trial production or small batch production of a certain model; b) when the design or technology is changed enough to cause certain characteristics and parameters to change; c) when there is an unacceptable difference between the inspection test results and the previous type test results. 62 Electric motors produced in batches shall be regularly sampled and the test time shall be at least once a year. 6.3 The frequency of formal tests on electric motors includes: All the tests are as follows:
b) Inspection of electrical distances and electrical clearances:
c) Determination of locked-rotor torque (measured in actual cold state);
d) Determination of minimum overspeed during starting;
e) Determination of maximum torque;
rise test:
g) Determination of input power ramp-up test;
) Measurement of efficiency and power readings:
Determination of current:
k) in the rotation;
1) thermal test:
m) determination of capacitor terminal current;
* long-term operation test:
0* non-stop 1 test;
P)* protection level test.
those with "*" are allowed to be tested only when the product is required. 6 The number of product prototypes for type test shall not exceed 3. If any unqualified items are found in the products tested, the number of products tested for this item shall be doubled. If the products are still qualified, the products can be purchased from the factory only after the defects are eliminated. 7. Packaging, accessories and storage
7.1 Each motor must have a nameplate on the machine during use. The nameplate material and the handwriting and markings on the nameplate should be guaranteed not to be erased or removed during the normal use of the motor: but the main engine is a matching electric motor When there is an agreement with the user, the following shall be provided on the motor brand: a) Manufacturer's name (ground): b) Motor model name: c) Output power: d) Rated voltage: F) Frequency and speed; JB/T9541 The color of the lead wire of the motor short cable group shall be clearly marked. 7.3 The motor shall have a grounding device. The motor certificate shall be accompanied by a certificate (one copy shall be provided for each batch of motors) and a product certificate. 7.5 The motor shall be supplied with the motor. 7.6 The motor shaft extension shall be protected from rust. The motor packaging shall avoid Avoid moisture damage during transportation. 7.8 The packaging and marking of the motor shall comply with GB191. There are no restrictions on the means of transportation of the motor, but the motor must not be damaged during transportation. 7.9 The motor should be placed in an environment with a temperature range of -10~+409, with a relative humidity of 90%. The motor should be placed in a well-ventilated warehouse and the air should not contain corrosive substances.20 The motor can still operate after 5000 continuous use under the condition of normal operation. 4.21 The surface of the electric peach shall not have any spots, bubbles, collisions, cracks and adhesion of dirt. 4.22 When the product is used according to the instructions of the manufacturer and the electric peach is properly used and stored, the manufacturer shall ensure that the motor can stop running within 1 year of use. The date of shipment shall not exceed 1 year. If the motor is damaged due to poor maintenance or cannot operate normally, the manufacturer shall repair or replace parts for the user free of charge.
5 Test method
51 The test method of the motor shall be carried out in accordance with the provisions of this standard and GBT9631. 52 The output power, efficiency and power rating shall be measured directly. Note: After the motor is applied with a fixed angle and runs for 10m, the S.3 surge test is carried out on the ventilation fan in accordance with the provisions of GB4706.1 and GB4706.27-199211. The test density is the most unfavorable electrical sequence for the motor between 0.94% and 1.% of the rated current, and the 5.4 discharge current is measured according to GB4706.1 and GB4706.27-1992! 5.5 Noise level test is carried out according to GB/T10069.1:
5.6 Heat reduction test is carried out according to GBT2423.3, and the test cycle is 2d. 5.7 Long-term operation test is carried out on the ventilation fan according to 6.13 of GB814806-1993. %8 Non-positive belt test is carried out on the ventilation fan according to GB4706.1 and Chapter 19 of GB4706.27-1992. 5.9 External protection grade test is carried out according to the relevant provisions of GB/T4942.1. 6 Inspection regulations
Each electric appliance shall undergo inspection test. The inspection test is as follows: 6.1
6,1.1 Mechanical inspection:
a) Appearance quality inspection:
b) Check whether the motor is assembled completely and correctly: the motor should rotate smoothly and quickly without abnormality:
d) Installation size inspection;
) Inspection of radial runout.
(.1.2 Determination of the stator assembly current under actual cold state. 6.1.3 Determination of the insulation resistance of the winding to the shell (the cold insulation resistance can be measured during the inspection test, but the hot insulation resistance should be guaranteed to be not less than 2M
6.1.4 No-load test:
) Determination of no-load current power:
b) No-load running.
6.13 Determination of the locked-rotor current loss.
6.1 specifies the battery test for the machine, and 6.17 specifies the voltage test.
Each product must be inspected according to clauses a, b, c and 6.1.3.6.1.4, 6.1.6, and 6.1.7. Other items may be changed continuously. The number of products sampled should not be less than 2% of each batch of products [not more than 3 sets in a group). If any unit fails any item during the product test, the number of products sampled should be doubled, and the test of the item should be carried out simultaneously. If any unit still fails, the item should be considered as unqualified. 62 Type test
JB/T9541
6.2! The following tests must be carried out for the following: a) the first trial production or small batch production of a certain model; b) when the design or technology is changed enough to cause certain characteristics and parameters to change; c) when there is an unacceptable difference between the inspection test results and the previous type test results. 62 Electric motors produced in batches shall be regularly sampled and the test time shall be at least once a year. 6.3 The frequency of formal tests on electric motors includes: All the tests are as follows:
b) Inspection of electrical distances and electrical clearances:
c) Determination of locked-rotor torque (measured in actual cold state);
d) Determination of minimum overspeed during starting;
e) Determination of maximum torque;
rise test:
g) Determination of input power ramp-up test;
) Measurement of efficiency and power readings:
Determination of current:
k) in the rotation;
1) thermal test:
m) determination of capacitor terminal current;
* long-term operation test:
0* non-stop 1 test;
P)* protection level test.
those with "*" are allowed to be tested only when the product is required. 6 The number of product prototypes for type test shall not exceed 3. If any unqualified items are found in the products tested, the number of products tested for this item shall be doubled. If the products are still qualified, the products can be purchased from the factory only after the defects are eliminated. 7. Packaging, accessories and storage
7.1 Each motor must have a nameplate on the machine during use. The nameplate material and the handwriting and markings on the nameplate should be guaranteed not to be erased or removed during the normal use of the motor: but the main engine is a matching electric motor When there is an agreement with the user, the following shall be provided on the motor brand: a) Manufacturer's name (ground): b) Motor model name: c) Output power: d) Rated voltage: F) Frequency and speed; JB/T9541 The color of the lead wire of the motor short cable group shall be clearly marked. 7.3 The motor shall have a grounding device. The motor certificate shall be accompanied by a certificate (one copy shall be provided for each batch of motors) and a product certificate. 7.5 The motor shall be supplied with the motor. 7.6 The motor shaft extension shall be protected from rust. The motor packaging shall avoid Avoid moisture damage during transportation. 7.8 The packaging and marking of the motor shall comply with GB191. There are no restrictions on the means of transportation of the motor, but the motor must not be damaged during transportation. 7.9 The motor should be placed in an environment with a temperature range of -10~+409, with a relative humidity of 90%. The motor should be placed in a well-ventilated warehouse and the air should not contain corrosive substances.20 The motor can still operate after 5000 continuous use under the condition of normal operation. 4.21 The surface of the electric peach shall not have any spots, bubbles, collisions, cracks and adhesion of dirt. 4.22 When the product is used according to the instructions of the manufacturer and the electric peach is properly used and stored, the manufacturer shall ensure that the motor can stop running within 1 year of use. The date of shipment shall not exceed 1 year. If the motor is damaged due to poor maintenance or cannot operate normally, the manufacturer shall repair or replace parts for the user free of charge.
5 Test method
51 The test method of the motor shall be carried out in accordance with the provisions of this standard and GBT9631. 52 The output power, efficiency and power rating shall be measured directly. Note: After the motor is applied with a fixed angle and runs for 10m, the S.3 surge test is carried out on the ventilation fan in accordance with the provisions of GB4706.1 and GB4706.27-199211. The test density is the most unfavorable electrical sequence for the motor between 0.94% and 1.% of the rated current, and the 5.4 discharge current is measured according to GB4706.1 and GB4706.27-1992! 5.5 Noise level test is carried out according to GB/T10069.1:
5.6 Heat reduction test is carried out according to GBT2423.3, and the test cycle is 2d. 5.7 Long-term operation test is carried out on the ventilation fan according to 6.13 of GB814806-1993. %8 Non-positive belt test is carried out on the ventilation fan according to GB4706.1 and Chapter 19 of GB4706.27-1992. 5.9 External protection grade test is carried out according to the relevant provisions of GB/T4942.1. 6 Inspection regulations
Each electric appliance shall undergo inspection test. The inspection test is as follows: 6.1
6,1.1 Mechanical inspection:
a) Appearance quality inspection:
b) Check whether the motor is assembled completely and correctly: the motor should rotate smoothly and quickly without abnormality:
d) Installation size inspection;
) Inspection of radial runout.
(.1.2 Determination of the stator assembly current under actual cold state. 6.1.3 Determination of the insulation resistance of the winding to the shell (the cold insulation resistance can be measured during the inspection test, but the hot insulation resistance should be guaranteed to be not less than 2M
6.1.4 No-load test:
) Determination of no-load current power:
b) No-load running.
6.13 Determination of the locked-rotor current loss.
6.1 specifies the battery test for the machine, and 6.17 specifies the voltage test.
Each product must be inspected according to clauses a, b, c and 6.1.3.6.1.4, 6.1.6, and 6.1.7. Other items may be changed continuously. The number of products sampled should not be less than 2% of each batch of products [not more than 3 sets in a group). If any unit fails any item during the product test, the number of products sampled should be doubled, and the test of the item should be carried out simultaneously. If any unit still fails, the item should be considered as unqualified. 62 Type test
JB/T9541
6.2! The following tests must be carried out for the following: a) the first trial production or small batch production of a certain model; b) when the design or technology is changed enough to cause certain characteristics and parameters to change; c) when there is an unacceptable difference between the inspection test results and the previous type test results. 62 Electric motors produced in batches shall be regularly sampled and the test time shall be at least once a year. 6.3 The frequency of formal tests on electric motors includes: All the tests are as follows:
b) Inspection of electrical distances and electrical clearances:
c) Determination of locked-rotor torque (measured in actual cold state);
d) Determination of minimum overspeed during starting;
e) Determination of maximum torque;
rise test:
g) Determination of input power ramp-up test;
) Measurement of efficiency and power readings:
Determination of current:
k) in the rotation;
1) thermal test:
m) determination of capacitor terminal current;
* long-term operation test:
0* non-stop 1 test;
P)* protection level test.
those with "*" are allowed to be tested only when the product is required. 6 The number of product prototypes for type test shall not exceed 3. If any unqualified items are found in the products tested, the number of products tested for this item shall be doubled. If the products are still qualified, the products can be purchased from the factory only after the defects are eliminated. 7. Packaging, accessories and storage
7.1 Each motor must have a nameplate on the machine during use. The nameplate material and the handwriting and markings on the nameplate should be guaranteed not to be erased or removed during the normal use of the motor: but the main engine is a matching electric motor When there is an agreement with the user, the following shall be provided on the motor brand: a) Manufacturer's name (ground): b) Motor model name: c) Output power: d) Rated voltage: F) Frequency and speed; JB/T9541 The color of the lead wire of the motor short cable group shall be clearly marked. 7.3 The motor shall have a grounding device. The motor certificate shall be accompanied by a certificate (one copy shall be provided for each batch of motors) and a product certificate. 7.5 The motor shall be supplied with the motor. 7.6 The motor shaft extension shall be protected from rust. The motor packaging shall avoid Avoid moisture damage during transportation. 7.8 The packaging and marking of the motor shall comply with GB191. There are no restrictions on the means of transportation of the motor, but the motor must not be damaged during transportation. 7.9 The motor should be placed in an environment with a temperature range of -10~+409, with a relative humidity of 90%. The motor should be placed in a well-ventilated warehouse and the air should not contain corrosive substances.3. The insulation resistance of the winding to the shell is determined (the insulation resistance in the cold state can be measured during the inspection test, but the insulation resistance in the hot state should be guaranteed to be no less than 2M
6.1.4 No-load test:
) Determination of no-load current power:
b) Reduce the no-load load.
6.13 Determination of locked-rotor current loss.
6.1 specifies the battery test for the machine, and 6.17 specifies the voltage test.
Each product must be inspected according to clauses a, b, c and 6.1.3.6.1.4, 6.1.6, and 6.1.7. Other items may be changed continuously. The number of products sampled should not be less than 2% of each batch of products [not more than 3 sets in a group). If any unit fails any item during the product test, the number of products sampled should be doubled, and the test of the item should be carried out simultaneously. If any unit still fails, the item should be considered as unqualified. 62 Type test
JB/T9541
6.2! The following tests must be carried out for the following: a) the first trial production or small batch production of a certain model; b) when the design or technology is changed enough to cause certain characteristics and parameters to change; c) when there is an unacceptable difference between the inspection test results and the previous type test results. 62 Electric motors produced in batches shall be regularly sampled and the test time shall be at least once a year. 6.3 The frequency of formal tests on electric motors includes: All the tests are as follows:
b) Inspection of electrical distances and electrical clearances:
c) Determination of locked-rotor torque (measured in actual cold state);
d) Determination of minimum overspeed during starting;
e) Determination of maximum torque;
rise test:
g) Determination of input power ramp-up test;
) Measurement of efficiency and power readings:
Determination of current:
k) in the rotation;
1) thermal test:
m) determination of capacitor terminal current;
* long-term operation test:
0* non-stop 1 test;
P)* protection level test.
those with "*" are allowed to be tested only when the product is required. 6 The number of product prototypes for type test shall not exceed 3. If any unqualified items are found in the products tested, the number of products tested for this item shall be doubled. If the products are still qualified, the products can be purchased from the factory only after the defects are eliminated. 7. Packaging, accessories and storage
7.1 Each motor must have a nameplate on the machine during use. The nameplate material and the handwriting and markings on the nameplate should be guaranteed not to be erased or removed during the normal use of the motor: but the main engine is a matching electric motor When there is an agreement with the user, the following shall be provided on the motor brand: a) Manufacturer's name (ground): b) Motor model name: c) Output power: d) Rated voltage: F) Frequency and speed; JB/T9541 The color of the lead wire of the motor short cable group shall be clearly marked. 7.3 The motor shall have a grounding device. The motor certificate shall be accompanied by a certificate (one copy shall be provided for each batch of motors) and a product certificate. 7.5 The motor shall be supplied with the motor. 7.6 The motor shaft extension shall be protected from rust. The motor packaging shall avoid Avoid moisture damage during transportation. 7.8 The packaging and marking of the motor shall comply with GB191. There are no restrictions on the means of transportation of the motor, but the motor must not be damaged during transportation. 7.9 The motor should be placed in an environment with a temperature range of -10~+409, with a relative humidity of 90%. The motor should be placed in a well-ventilated warehouse and the air should not contain corrosive substances.3. The insulation resistance of the winding to the shell is determined (the insulation resistance in the cold state can be measured during the inspection test, but the insulation resistance in the hot state should be guaranteed to be no less than 2M
6.1.4 No-load test:
) Determination of no-load current power:
b) Reduce the no-load load.
6.13 Determination of locked-rotor current loss.
6.1 specifies the battery test for the machine, and 6.17 specifies the voltage test.
Each product must be inspected according to clauses a, b, c and 6.1.3.6.1.4, 6.1.6, and 6.1.7. Other items may be changed continuously. The number of products sampled should not be less than 2% of each batch of products [not more than 3 sets in a group). If any unit fails any item during the product test, the number of products sampled should be doubled, and the test of the item should be carried out simultaneously. If any unit still fails, the item should be considered as unqualified. 62 Type test
JB/T9541
6.2! The following tests must be carried out for the following: a) the first trial production or small batch production of a certain model; b) when the design or technology is changed enough to cause certain characteristics and parameters to change; c) when there is an unacceptable difference between the inspection test results and the previous type test results. 62 Electric motors produced in batches shall be regularly sampled and the test time shall be at least once a year. 6.3 The frequency of formal tests on electric motors includes: All the tests are as follows:
b) Inspection of electrical distances and electrical clearances:
c) Determination of locked-rotor torque (measured in actual cold state);
d) Determination of minimum overspeed during starting;
e) Determination of maximum torque;
rise test:
g) Determination of input power ramp-up test;
) Measurement of efficiency and power readings:
Determination of current:
k) in the rotation;
1) thermal test:
m) determination of capacitor terminal current;
* long-term operation test:
0* non-stop 1 test;
P)* protection level test.
those with "*" are allowed to be tested only when the product is required. 6 The number of product prototypes for type test shall not exceed 3. If any unqualified items are found in the products tested, the number of products tested for this item shall be doubled. If the products are still qualified, the products can be purchased from the factory only after the defects are eliminated. 7. Packaging, accessories and storage
7.1 Each motor must have a nameplate on the machine during use. The nameplate material and the handwriting and markings on the nameplate should be guaranteed not to be erased or removed during the normal use of the motor: but the main engine is a matching electric motor When there is an agreement with the user, the following shall be provided on the motor brand: a) Manufacturer's name (ground): b) Motor model name: c) Output power: d) Rated voltage: F) Frequency and speed; JB/T9541 The color of the lead wire of the motor short cable group shall be clearly marked. 7.3 The motor shall have a grounding device. The motor certificate shall be accompanied by a certificate (one copy shall be provided for each batch of motors) and a product certificate. 7.5 The motor shall be supplied with the motor. 7.6 The motor shaft extension shall be protected from rust. The motor packaging shall avoid Avoid moisture damage during transportation. 7.8 The packaging and marking of the motor shall comply with GB191. There are no restrictions on the means of transportation of the motor, but the motor must not be damaged during transportation. 7.9 The motor should be placed in an environment with a temperature range of -10~+409, with a relative humidity of 90%. The motor should be placed in a well-ventilated warehouse and the air should not contain corrosive substances.