This standard specifies the terminology, type, basic parameters and dimensions, technical requirements, inspection methods, marking and packaging of dial caliper indicators. This standard applies to dial caliper indicators with graduation values of 0.01, 0.02 and 0.05 mm. JB/T 8346-1996 Dial caliper indicator JB/T8346-1996 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China JB/T8346-96 Indicator table of dial caliper Published on April 11, 1996 Ministry of Machinery Industry of the People's Republic of China Implemented on October 1, 1996 Mechanical Industry Standard of the People's Republic of China Indicator table of dial caliper 1 Main content and applicable products JB/T8346.96 This standard stipulates The terminology, type, basic format and size, technical requirements, inspection methods, marking and packaging of dial gauges are introduced. This standard is applicable to dial gauges with a graduation value of 0.01, 0.02, and 0.0Gmm. 2 Reference standards GB1219 Vertical indicator GB/T6317 with dial gauge 3 Terms 3.1 Caliper indicator Special caliper indicator that converts linear displacement into angular displacement through a mechanical transmission system. 3.2 Working strokeWww.bzxZ.net The linear displacement required for the dial gauge core assembly to complete the engagement. 4 Type, for this number 4. 1 Type The type of the indicator is [Type I and Type II, see Figure 1, Figure 2. The figures are only for explanation and do not represent the detailed structure], machine components and movement resistance parts, approved by the Ministry of Machinery Industry on April 11, 1996, No. 1-0 implementation JB/T8346-96 4.2 The scale value and one-turn indication value of the indicator are shown in Table 1. Table 1 Recommended indicator installation dimensions are shown in Table 2 and Figure Installation scale Scale excess volume ~·3im 4.4 The indicator should have a locking mechanism. 19±5. 042 B=t, 030 18±0.012 19±0.042 YB/T8346—96 .5±..3c 4.5 The graduation value is 0.0t, 0.mm. The indicating table shall be in accordance with its complete carrying device, 5 Technical requirements 17.6±0.042 27±6.G42 2:.3±0.042 6.416.c:3 5.1 The indicating table shall not have defects such as scratches, spots, rust, flying ideas, etc. that affect the appearance and pressure performance. 5.2 The rotating parts of the indicating table shall rotate smoothly, flexibly and normally without any looseness or looseness. 5.3 The indicator should be able to rotate in the air and cannot fall off. 5.4 The radial pressure of the pointer shaft of the 1st type indicator should be within the range of 0.7~1 mm: Note that the length of the short scale line on the indicator should be within the range of 0.7~1 mm. 5. The distance between the tip of the pointer and the dial should not be greater than that specified in Table 3: Table Cui Shi Di 5.? The width of the scale line of the dial and the width of the pointer end of the dial should be (1.1~0.2rm: 5. The difference in the density of the dial should not be greater than 0.C5mm. 5.9 The scale line on the zero dial should be less than 0.m? 7.55±0.030 9. 320. 030 1O.37±G.G35 11.a±0.cs 13. 35 ±0. c, 14. 0 : 0. n35 The relative indication error of the scale, the total reading of the indication, the accuracy of the indication, and the return error should not exceed the provisions of the tenth meter, 5. ) Comfortable control Indicator time Indicator value overall design Indicator value variability Return error Maintenance inspection method 6.1 Inspection conditions 6.1.1 During inspection, the ambient temperature is 20±5℃. 6.1.2 The indicator and the inspection instrument shall be kept at the same temperature for at least 1h. 6.2 Inspection items and inspection methods JB/T 8346-96 Inspection items, inspection methods and inspection tools are shown in Table 5 and Figure 45 External filter, mutual action "Indicator's distance to space Torsion force Axis Radial force Short-term load length of the needle tip Distance between the tip and the dial Width of the dial and pointer Anzhou width|| tt||Interval between scale lines on the dial of the indicator Total reading of position Error of adjacent indications Variability of indication Testing method Eye contact is conducive to inspection Good main wheel, turn the gear lightly, check the good quality with felt hanging observation case eye contact or use a ruler to check (if there is a problem, check on the instrument) visual inspection (if there is a problem, check on the instrument) standard indicator is installed on The special tool will be used for the full working stroke in forward and reverse directions. The measuring points are determined according to the original indication error estimates of each measuring point, and the forward and reverse indication error curves are made. The maximum position of the highest point and the lowest point on the measuring line of the forward stroke indication is used as the total indication error curve, and the difference between the highest point and the lowest point on the ordinate of the corresponding measuring points on the two lines is calculated, or its maximum value is the same indication value as the indication type. Install the indicator on the starting point, midpoint and end point of the special testing machine, and repeat the measurement 3 to 5 times to find the difference between the maximum indication and the minimum indication at each location. Take the maximum value as the indication variability of the indicator. Based on the drawn upward and reverse indication error curves, find the stored value of the difference between the upward and reverse indication errors at each measuring point, and take the maximum value as the indication error. If the errors are relatively small, it will be a problem! Measure the point again 3 times, and make sure that the interval between the measuring points is at least 2 times. Take the level of the low level shown this time as the step indicator. The tool is a feeler gauge, and the tool display is a microscope. Special microscope burning microscope. Special safety test device. (The total safety is not guaranteed to be a special test range. (The uncertainty is that the card will be used to test the device. (It is not guaranteed to become a special test vibration device. (It is not guaranteed to become a special test vibration device. The degree of certainty is 7 Marking and packaging Direction of movement of the small indicator Positive and negative indication of the blood clot . Reverse travel indication of the blood clot 7.1 The small indicator should be marked 2Manufacturer's name or registered trademark: b. Graduation value: Product serial number. T.3The indicator packaging box should have the following: Manufacturer's name or registered trademark: b.Product name: e Graduation value. JB/T 8346--96 Heart-to-heart total visit ticket Force-to-adjacent error One-way error 7.3 The old indicator should be processed and packed before packaging to ensure that the product will not be damaged during transportation. 7. The goods should have product enterprise certification, which should be marked with standard number, product number, shaft gear adjustment and date of manufacture, and should be accompanied by the actual error value. Additional instructions, This standard was proposed by the National Quality and Safety Standardization Technical Committee and was drafted by the Ministry of Industry and Information Technology of China. The main author of this standard is Chen Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.