Standard ICS number:Shipbuilding and offshore structures>>Shipbuilding and offshore structures in general>>47.020.60 Marine electrical equipment
Standard Classification Number:Ships>>Marine electrical, observation and navigation equipment>>U62 marine electronic control device and measuring equipment
CB/T 3897-1999 Marine 16~125A plugs, sockets and connectors CB/T3897-1999 Standard download decompression password: www.bzxz.net
Some standard content:
UDC621.316.541:629.12 National Standard of the People's Republic of China GB1232190 CBh 3897-1999 Marine 16~125A plugs, socket-outletsand couplers 1990-04-20 Issued State Bureau of Technical Supervision 1990-12-01 Implementation Subject content and scope of application…… 2 Reference standards 3 Terms… 4 Product classification… 5 Technical requirements 6 Test methods 7·Inspection rules· 8 Marking, packaging, transportation and storage. Appendix A Grounding contact position diagram (supplement) Table of contents Appendix B Schematic diagram of plugs, sockets and connectors (reference) Times ........ (16) (19) (23) (24) (25) (26) National Standard of the People's Republic of China Marine 16~125A plugs, socket-outlets and couplers 1 Subject content and scope of application GB12321-90 This standard specifies the classification, technical requirements, test methods and inspection rules for marine 16~125A plugs, socket-outlets and couplers. This standard applies to plugs, sockets and connectors with an AC voltage of 50Hz or 60Hz, a rated voltage not exceeding 440V or a DC rated voltage not exceeding 220V, and a rated current of 16 to 125A, used in general ships, refrigerated containers and docks. However, it is not applicable to places with explosion hazards. 2 Reference standards GB2099 Packaging storage and transportation pictorial signs Technical conditions for single-phase and three-phase plugs and sockets GB2423.10 GB2423.16 GB2423.17 Basic environmental test regulations for electrical and electronic products are test A: low temperature test method Basic environmental test regulations for electrical and electronic products Basic environmental test regulations for electrical and electronic products Basic environmental test regulations for electrical and electronic products Basic environmental test regulations for electrical and electronic products Basic environmental test procedures for electronic products GB4942.2 Protection level of low-voltage electrical enclosures 3 Terms 3.1 Interlocking device Test B: High temperature test method Test Db: Alternating damp heat test method Test Fc: Vibration (sinusoidal) test method Test J: Mildew test method Test Ka: Salt mildew test method It refers to a mechanical structure that prevents the plug pin from being energized before the plug and socket or connector are plugged in, and can also prevent the plug pin from being pulled out when energized. 3.2 Retention device It refers to a mechanical structure that keeps the plug or connector in the normal working position when it is plugged in to prevent accidental disengagement. 4 Product classification 4.1 See Table 1 for basic parameters. Approved by the State Administration of Technical Supervision on April 20, 1990, and implemented on December 12, 1990 Rated current 3P+N++ 312321-90 50 or 60 50 or 60 50 or 60 Rated voltage 110 or 220 250 or 440 Grounding contact Clock position Note: ① The position of the grounding contact is determined by comparing the front of the socket with the clock face, setting the key slot position at 6 o'clock (6h), and then according to the clock position of the grounding socket, see Appendix A (supplement). 250V or 440V is only for refrigerated containers. 4.2 The arrangement diagram of the socket and the pin of the plug is shown in Figures 1 and 2. Current level Socket 5 Grounding hole Φ7 Socket 6 Grounding hole 8 Socket electric 8 Grounding hole Φ10 Socket 10 Grounding hole 12 Auxiliary publication Auxiliary hole GB12321—90 Socket $5 Grounding no 7 Socket 46 Grounding hole 8 Socket 8 |Grounding hole 10 Socket $10 Grounding hole $12 Auxiliary hole Auxiliary hole Schematic diagram of socket socket arrangement Socket 5 Grounding hole 7 Socket 46 Grounding hole Φ8 Socket 8 Grounding hole 10 Socket 10 Grounding hole 12 Current level Pin $5 Grounding pin $7 Broadcast pin 46 Ground pin 8 Pin 18 Ground pin center 10 Pin 10 Ground pin center 12 Assistance pin GB1232190 Pin $5 Ground pin 47 Pin: 6 Ground pin center 8 Pin 48 Ground pin 410 Pin 10 Ground pin 412|| tt||End auxiliary pin Figure 2 Schematic diagram of the pin arrangement of the plug Pin $5 Grounding pin Pin 46 Grounding pin 48 Pin 48 Grounding pin 410 3P+N+→ Pin 410 Anding pin 12 GB12321—90 4. The structure and dimensions of 316A and 32A sockets and connector sockets are shown in Figure 3 and Table 2. h R3.5±0.2 2P+↓ 3P+↓ 3P+N++ 3P+N++ 3P+↓ 3P+↓ 3P+N+→ Figures 316A and 32A sockets and connector sockets Chamfer of socket sleeve Phase and neutral line plug plate Earthing socket 3P+N+1 GB1232190 Continued Table 2 Note: 1) Within the distance specified by ts, d and L should be within the limit. If ts is exceeded, d and L can be greater than the specified value. 2) The dimensions of the socket d and d do not have to be circular, which is related to the pin. 3) For the socket with 3P+N++10 poles, the value of dimension h for the neutral line socket is 16.0mm. 4.4 The construction and dimensions of 16A and 32A plugs and connector plugs are shown in Figure 4 and Table 3. End of the plug Phase and neutral line plugs Insulating bushing Figure 416A and 32A plugs and connector plugsbzxZ.net Earthing plug 3P+N++ 2P+↓ 3P+↓ 3P+N+↓ 3P+N+G 3P+N++ 3P+↓ 3P+N++ Note: 1) Applicable to plugs with metal shells. d2 GB12321-90 2) Applicable to plugs with non-metallic shells. Limit Limit deviation Basic size Basic size GB12321-90 4.The structure and dimensions of the sockets and connector sockets of 563A and 125A without auxiliary jacks are shown in Figure 5 and Table 4. 15min R05min Figure 563A and 125A sockets and connector sockets without auxiliary holes Table 4 3P+N++ 3P+N++ 3P+N++ Chamfer of socket Phase and neutral sockets Earthing socket +1 03) With electrical interlock With mechanical interlock 21 or 40 Note: 1) Within a distance of 15mm, d and L should be within the limit value. If it exceeds 15mm, d and L can be greater than the specified value. 2) The dimensions of the socket d and dg do not have to be round, which is related to the pin. 3) For sockets with 3P+N+Pole, the depth h of the neutral contact should be less than the depth of the phase contact and greater than the depth of the grounding contact. 8 No interlock 21 or 40 GB12321-90 4.663A and 125A sockets and connector sockets with auxiliary jacks have a structure and dimensions shown in Figure 6 and Table 4. h, 63A and 125A sockets and connector sockets with auxiliary jacks Figure 6 Chamfer of socket sleeve Phase and neutral socket Auxiliary socket sleeve Grounding socket 4.763A and 125A plugs and connector plugs without auxiliary pins have a structure and dimensions shown in Figure 7 and Table 5. hg End of pin Phase and neutral pins Earth pin Figure 763A and 125A Plugs and connectors without auxiliary pins Plug insulation food Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.