Some standard content:
The standard of the Ministry of Chemical Industry of the People's Republic of China for polyvinyl chloride film adhesive is: HGhp. The standard of the Ministry of Chemical Industry of the People's Republic of China for polyvinyl chloride film adhesive is: HGh3319-19. The polyvinyl chloride film adhesive is made of perchlorethylene resin dissolved in esters, ethyl acetate and other agents, and is suitable for bonding and repairing polyvinyl chloride films. I. Technical requirements 1: Appearance color: colorless or slightly homogeneous adhesive liquid without mechanical impurities: 2. Liquid content, %: 20±2. 3. Peel strength, kg/ 2.5 cn1.5 II. Inspection method
4. Appearance
(1) Instrument: 250ml conical flask with stopper
(2) Density measurement method: Place 100g sample in a conical flask, remove the stopper, turn the flask upside down, and observe the thin layer of solution flowing down the flask wall. It should be qualified if there is no glue block or mechanical impurities. 5. Solid content
(1) Instrument: weighing bottle
Infrared oven
Electric heating oven
220V250W or 500W
The sensitivity is more than 0.0001
(2) Measurement method;|| tt||a, use two weighing bottles with known constant weight on the balance, weigh about 2 grams of sample each (accuracy 0.0002 grams), place the weighing bottles in a 100±5°C infrared oven (the oven door is slightly open) and bake for 1.5 hours, then move to a 100±2°C oven and bake for 2.5 hours, take out and move to a desiccator to cool. Weigh and calculate, and take the average of the two samples. www.bzxz.net
The Ministry of Chemical Industry of the People's Republic of China issued the Chemical Industry
Hangzhou City
Trial on April 1, 1979
Hangzhou Wanli Chemical Industry
Total 3 No. 2
HG 4—1197—7S
b. Place the weighed sample in a constant temperature oven at 100±2 for 4 hours, then move it to a desiccator to cool. Weigh and calculate, and take the average value of the two samples (this method is only used when there is no infrared oven, and the oven heating wire must not be exposed to avoid burning). c. Calculation:
Solid egg content%:
Where, one is the weight of the sample and the weighing bottle, the other is the weight of the weighing bottle. i.
Ring. ...Weigh the single dirty weight,. .
6. Peel strength:
(1) Equipment: Strong test machine (load 0 = 50kg), polyvinyl chloride film test piece (length 46cm, width 2.5cm, thickness 0.4mm brush or writing brush. (2) Determination method
Peel strength: According to (532-76).
Test piece preparation: Take 5 pieces of the film carefully selected according to the specifications, weigh them in turn, and then lay them flat on the operating table. Use a brush to filter the mixture and evenly apply it on the film. The amount should be moderate, so that the entire adhesive layer is evenly applied. After the glue coating is completed, wait for the solvent to evaporate. When the film is not too sticky when touched by hand, fold the film in half and glue it together. Press it flat to prevent curling and cracking. Then weigh it in turn. Change the glue coating amount to about 0.4-0.7%. Finally, hang the glued test piece in a dry and ventilated place. Leave it for 24 hours. Note: (i) The test piece should be dry, clean and flat. Glue removal and bonding require quick and accurate actions. ③ Leave 2cm of space on both sides of the test piece.
III. Acceptance rules
7. This product shall be accepted by the technical inspection department of the manufacturer in accordance with this standard. Each batch of products shall be accompanied by a quality certificate.
8. During acceptance, samples shall be taken from 5% of the total number of packaging boxes in each batch. When the number of students is small, the sample shall be less than 4 boxes.
9 Take 5 grams from each box, 20 grams from each bottle, so that the total weight of each sampling is not less than 400 grams. 10: Mix the samples evenly, divide them into two parts, put them into two sterile bottles with magic stoppers, and affix labels to indicate the product name, factory name, batch number, and sampling date. ,≤11. One sample is analyzed in the laboratory, and the other sample is stored according to the storage conditions and storage period for repeated analysis and arbitration.
HG 4 —1197T9
Total 3 Page 3
12: If the sampling inspection is unqualified: re-sampling should be carried out. If it is still unqualified, the batch of products is unqualified.
IV. Packaging, transportation and storage
13. Adhesives should be packed in clean, dry, sealed containers with polyethylene inner stoppers. The container should be labeled with: product name, manufacturer name, production date. 14. This adhesive should be stored in a dry, cool, heat-insulated warehouse and should be kept away from direct sunlight. 15. Under the condition of sealing the original bottle, the storage period is one year. If the product still meets the various quality indicators of the standard after the storage period, it is still a qualified product. 16. When transporting the product, it should prevent bacteria growth and moonlight, and should comply with the transportation regulations of the transportation department on flammable goods.
Ministry of Chemical Industry of the People's Republic of China
Ministry Standard
Polyurethane Film Adhesive
HG 4-79
Published by Technical Standards Press
(Beijing Fuwai Sanlihe)
Printed in the Printing House of Technical Standards Press
Distributed by Beijing Distribution Office of Xinhua Bookstore
Announced by Xinhua Bookstores in various places
deffouee yon
Format 850×11681/32 Printing Sheet 1/4 Number of Words 3.000 First Printing in July 1979
First Edition in July 1979
Print Quantity 1-9,00
Book Number: 131692-3118
Price 0.04 Yuan
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.