title>HG 3320-1987 Water-soluble phenolic resin adhesive for coated abrasives - HG 3320-1987 - Chinese standardNet - bzxz.net
Home > HG > HG 3320-1987 Water-soluble phenolic resin adhesive for coated abrasives
HG 3320-1987 Water-soluble phenolic resin adhesive for coated abrasives

Basic Information

Standard ID: HG 3320-1987

Standard Name: Water-soluble phenolic resin adhesive for coated abrasives

Chinese Name: 涂附磨具用水溶性酚醛树脂胶粘剂

Standard category:Chemical industry standards (HG)

state:in force

standard classification number

Standard ICS number:Rubber and plastics industry >> 83.180 Adhesives and adhesive products

Standard Classification Number:Chemicals>>Synthetic Materials>>G39 Adhesive

associated standards

alternative situation:Original standard number ZB G39004-87

Publication information

other information

Introduction to standards:

Original standard number ZB G39004-87 HG 3320-1987 Water-soluble phenolic resin adhesive for coated abrasives HG3320-1987 Standard download decompression password: www.bzxz.net

Some standard content:

Professional Standard of the People's Republic of ChinaWww.bzxZ.net
ZBG39004--87
Complete: HG3320-1p8)
Water-soluble phenolic
resin adhesive for coated abrasives1987-11-23Published
1988-07-01Implementation
Published by the Ministry of Chemical Industry of the People's Republic of China Professional Standard of the People's Republic of China
Water-soluble phenolic resin adhesive for coated abrasivesScope of application
This standard applies to water-soluble phenolic resin adhesive for dry coated abrasives. 2 Technical requirements
The product shall meet the requirements of Table 1.
Test method
3.1 Appearance
Body content,
Storage stability, h
Storage period, d
Water miscibility, %
Not less than
Not less than}
Compression shear strength, N/cm2
Viscosity, Pa.s
Gel time, cut in**
Product appearance is inspected by visual inspection.
*This is a storage test, which is recommended for production inspection. Not less than
*This can be used as a reference indicator, and its specific requirements are determined by both supply and demand parties. Approved by the Ministry of Chemical Industry of the People's Republic of China on November 23, 1987, ZBG39004-B7
Adjusted to HG 332.0-198)
Desorption, liquid-containing, no distinction between elements, opening and materials and objects 7.1
300~500
Implementation on July 1, 1988
3.2 Determination of solid content
ZBG 39004--87
8.2.1 Instruments
3.2.1.1 Constant temperature drying oven: 0~300℃, accurate to ±1℃. : 3.2.1.2 Analytical balance: sensitivity 0.001g. 3,2.1.3 Desiccant: Use color-changing silica gel or anhydrous calcium chloride as desiccant. 8.2.1.4 Weighing bottle: 40mm×25mm.
8.2.2 Test steps
Accurately weigh 1.000~1.50g of the sample into a weighing bottle that has been weighed to a constant weight, and place it in an oven preheated to 60℃. Within 25~30min, raise the oven temperature to 135±1℃. After keeping the constant temperature for 1h, move the sample into a desiccator, cool it to room temperature, and weigh it. 3.2.3 Test results
The solid content X (%) is calculated as follows:
Where: G—weight of the sample after drying, g, G
weight of the sample before drying, g.
The average value of the test data of two parallel samples is taken as the test result, but the difference between the values ​​of the two parallel sample tests shall not be greater than 1%. 3.3 Determination of storage stability-! Acceleration method 3.3.1 Instruments
3.3.1.1 Constant temperature water bath: accurate to =1℃. 3.3.1.2 Large tray: sensitivity 0.1g.
3.3.1.3 Thermometer: ~100℃, 1℃ division. It should comply with the provisions of JB1066-67 "Technical conditions for industrial glass thermometers and experimental glass thermometers".
3.3.1.4 Test tube: diameter 18mm, height 180mm, it should comply with the provisions of QB519-66 "Beakers and flasks". 3.3.2 Test steps
Weigh 10.0g of sample into the test tube, gently plug the mouth of the test tube with a rubber stopper, put it into a constant temperature bath with a bath temperature controlled at 60±1, and the sample liquid level should be 2cm lower than the water bath liquid level. Note the start time, and after about 10 minutes, plug the rubber stopper tightly. From the beginning of the test, tilt the test tube once every 1 hour until the sample stops flowing, and record the gel time (expressed in hours). 3.4 Determination of storage period
The determination of product storage period shall be carried out in accordance with GB7751--87 "Determination method of storage period of adhesives". 3.5 Determination of water miscibility
3.5.1 Instrument
3.5.1.1 Constant temperature spectrum: accurate to +1℃,
3.5.1.2 Pan balance: sensitivity 0.1g,
3.5.1.3 Thermometer: 0~5U℃, graduation 1℃. It should comply with the provisions of JB1066. 3.5.1.4 Burette: 50ml, it should comply with the provisions of QB702--80 "Burette". 3.5.1.5 Erlenmeyer flask: 250ml, it should comply with the provisions of QB519. 3.5.2 Test steps
Weigh 5.00g of sample into a conical flask1, insert a thermometer, and place it in a constant temperature controlled at 23±1℃. When the sample temperature reaches 23±1, use a burette to drip water of the same temperature into the sample, shake the hook, and after the water and sample are evenly mixed, drip more water until it becomes slightly turbid, which is the end point. Read the volume of the dripped water, and calculate the result in grams of water added. 3.5.3 Test results
The percentage of water miscibility is calculated as follows: 2
-water mixing fraction, %,
W--amount of water dripped, maximum,
GThe weight of the sample, g.
3.6H determination
ZB G 39004—87
Use precision test paper with a pH range of 4.5 to 9.5 to test the pH of the sample. (2)
3.7 Determination of compressive shear strength
3.7.1 Test block material: Use birch blocks with a moisture content of 8 to 15%, a bulk density greater than 0.5 g/cm2, a thickness of 10 mm after treatment, and a smooth bonding surface, and make the main fiber direction parallel to the material center line shown in Figure 1. 3.7.2 Sample preparation: Apply the prepared adhesive quickly and evenly to the bonding surface of the test block at a ratio of about 100 g/m*. Glue so that the two sides parallel to the material center line are consistent and close, and leave for 20 to 40 minutes. Heat press at 130 to 140°C under a pressure of 98 to 147 N/cm2. The assimilation time is determined by the thickness of the glue, calculated as 60s/mm. Then the specimen is processed into the shape and size shown in the figure, and a total of 12 specimens are prepared, and the actual bonding surface of each specimen is measured. Load direction
Adhesion 25×25
Raw practice push square
Test block, shape and size of the specimen
3.7.3 Testing machine: The testing machine should be able to ensure that the load when the specimen is destroyed is within the range of 15% to 85% of its range. The loading speed is not more than 9.8kN per minute.
3.7.4 Test steps: Install the specimen on the test machine fixture. ", so that the fixture is consistent with the specimen load surface, turn on the test machine, and measure the maximum load (N) when the specimen is wrinkled.
3.7.5 Test results: Use the measured bonding area (cm\) to divide the maximum load when the specimen is destroyed, and calculate the compressive shear strength (N/cm2) of each specimen. Then use the percentage of the bonding area to calculate the area of ​​damage to the adherend (wood), and mark its damage rate 3
ZB G 39004-87
(%). Take the arithmetic mean of the compressive shear strength of the 12 samples as the compressive shear strength of the inspection batch product. If the damage rate of the adherend is greater than 50%, and the average compressive shear strength is lower than the specified index, it is necessary to re-make the sample for testing. The test results are recorded in the record sheet. Test result record sheet
Shrinkage shear strength
Ratio
Glue name
Curing agent
N/cm2 (water-material damage rate, %)
8.8 Determination of viscosity
The viscosity is determined in accordance with GB2794-81 "Test method for viscosity of adhesives (rotational viscometer method)". 3.9 Determination of gel time
3.9.1 Apparatus
Constant temperature oil bath, accurate to ±1°C.
Pan balance: sensitivity 0.1g.
Test tube: diameter Φ18mm, height 180mm, should comply with the provisions of QB519. Temperature range: 0~200°C, division 2, should comply with the provisions of JB1066. 3.9.1.5 Stopwatch.
3.9.1.6 Glass rod: diameter Φ4mm, length 300mm. 3.9.2 Test steps
Weigh 5.0g of sample into a test tube, insert a glass rod, and immerse them in an oil bath controlled at 135±1.5℃ for 1 minute. Make sure the sample surface is 2cm below the oil bath surface. At the same time, record the time and stir with a glass rod until it can no longer be stirred. Record the time and test at least two samples. Take the average value, which is the gel time of the sample. 4 Inspection rules
4.1. Products made of the same raw materials, produced at the same time and submitted for inspection at the same time constitute an inspection batch. 4.2. Products are sampled in accordance with the sampling regulations for Type A products in GB3186-81 "Sampling of Coating Products". 3. Unless otherwise specified, each batch of products shall be inspected in accordance with the requirements of Table 1. If one of the inspection results is unqualified, double samples shall be taken for retesting of the unqualified items. If the retest result is still unqualified, the batch of products shall be unqualified. 4.4. Qualified products must be accompanied by a product inspection certificate. 5. Packaging, marking, transportation and storage
Products are packaged in iron drums lined with plastic.
5.2. When the product leaves the factory, the following contents shall be indicated on the outer packaging: product name and brand!
Packaging weight!
Production batch number and production date
Name of the production unit,
Storage period,
Other contents that must be indicated.
The product should be handled gently during transportation and avoid exposure to sunlight. 5.
ZBG89004-87
The product should be sealed and stored in a cool and ventilated place with an ambient temperature below 20℃. Additional instructions:
This standard is under the jurisdiction of Shanghai Rubber Products Research Institute. This standard was drafted by Guizhou Chemical Research Institute. The main drafters of this standard are Gong Mingli and Liu Chunpai. People's Republic of China
Professional Standard
Water-soluble phenolic resin adhesive for coated abrasives ZBG 39004-87
Published by China Standards Press
(Beijing Fuwai Sanlihe)
Printed by China Standards Press Beijing Printing Factory
Distributed by Xinhua Bookstore Beijing Distribution Office Sold by Xinhua Bookstores in various places Copyright is exclusive and may not be reproduced
Format 880×12301/16 Printing sheet 1/2 Number of words 9000 First edition in November 1988 Second printing in November 1988 Number of copies 1-2000
# Number: 155066-27163
Price 0.4 yuan
Zongbai 101-53
(8fr-orsbh
-*006698z
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.