title>JB/T 2001.47-1999 Airlock valve core for water system pump station (PN=20, 31.5MPa) - JB/T 2001.47-1999 - Chinese standardNet - bzxz.net
Home > JB > JB/T 2001.47-1999 Airlock valve core for water system pump station (PN=20, 31.5MPa)
JB/T 2001.47-1999 Airlock valve core for water system pump station (PN=20, 31.5MPa)

Basic Information

Standard ID: JB/T 2001.47-1999

Standard Name: Airlock valve core for water system pump station (PN=20, 31.5MPa)

Chinese Name: 水系统 泵站用气闸阀芯(PN=20、31.5MPa)

Standard category:Machinery Industry Standard (JB)

state:in force

Date of Release1999-06-28

Date of Implementation:2000-01-01

standard classification number

Standard ICS number:Fluid systems and general parts >> 23.100 Fluid power systems

Standard Classification Number:Machinery>>General Parts>>J20 Hydraulic and Pneumatic Devices

associated standards

alternative situation:JB 2050-1984

Publication information

other information

Focal point unit:Metallurgical Equipment Standardization Technical Committee

Introduction to standards:

JB/T 2001.47-1999 JB/T 2001.47-1999 Airlock valve core for water system pump station (PN=20, 31.5MPa) JB/T2001.47-1999 Standard download decompression password: www.bzxz.net

Some standard content:

IC.s$ 23.110
Machinery Industry Standard of the People's Republic of China
JB/T 2001.1~2001.74—1999
Water system assembly and parts1999-06-28 Issued
National Machinery Industry Bureau
2(-01-U1 Implementation
Machinery Industry Standard of the People's Republic of China
Water System
Air Gate Valve Core for Pump Station
Water sysleru Core of gfs shut off vahveforwateraccumulator
(PN=20, 31.5MPa]
The standard specifies the type, size and requirements of the air gate core of the pump station, IH-T 2001.47—1999www.bzxz.net
Find Fee 32050-84
Standard application standard pressure is 20, 31.5MPa, and is used to control the air master core of the high-pressure air pipeline in the pump station of the actuator.
2 Type and size
2.1V1n, D25mm. The steps and dimensions of the air lock valve core are in accordance with the provisions of Figure 1 and 1: [Alarm rod: 2 Pressure flow: 3 Pressure change: 4 V-shaped seal: 5-Support ring: 6 Seal; 7-Pad: 8-Two seats: 9-Tao: 100-shaped seal ring Figure 1
National Machinery Industry Bureau approved 2Hchuan-Small 1-{] implementation on June 28, 1999
J37T 21m1.47
JB-T 200I.47.2
JB/T 2001.47—999
1.2DN40, DN65mm core type and size according to Figure 2, Table 2. 1- Rod: 2- Small dry whole: 3- Jade check: 4- Use cumulative dry separation, 5- V-throat sealing rate: 6- Support damage: 7- Out of sealing rate, difference
SO-shaped density: - Cup: 1G- Account needle: 11- Screw: 12- Pressure space: 13- Valve: 14- Seat: 150- Shape time network cabinet 2
R/2K1147
JB-T2001.47.4
3 Technical requirements
JET 2001.47—1999
3.1 Nominal pressure 31.5MPu, test pressure 42MPa. 20MPa below the nominal pressure, test pressure 30MP
3.2 During the test, the pressure drop phenomenon of the steel mouth is not very leaky, and the stroke
3.3TIN0, DN6Smm air valve core, in the closed state, the lower chamber pressure is not allowed to be full. 4 Marking example
Nominal light air core:
Air brake valve core DNidJB.T2001.47--1999
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.