drafter:Wu Yizhou, Wei Zhuyun, Zhao Shijie, Wang Meiyun, Guo Yufang
Drafting unit:Guangzhou Electrical Equipment Research Institute, Lhai Electrical Equipment Research Institute, Tianjin Electrical Equipment Research Institute
Focal point unit:Guangzhou Electrical Equipment Research Institute
Proposing unit:Guangzhou Electrical Equipment Research Institute
Publishing department:Ministry of Machinery Industry of the People's Republic of China
This standard specifies the climate protection type and environmental conditions, technical requirements, test methods, acceptance rules, marking, packaging and storage of tropical low-voltage electrical appliances. Matters not specified in this standard shall comply with the provisions of the corresponding ordinary low-voltage electrical appliance standards. This standard applies to tropical low-voltage electrical appliances. JB/T 834-1999 Technical requirements for tropical low-voltage electrical appliances JB/T834-1999 Standard download decompression password: www.bzxz.net
Some standard content:
K34 JB Pressing Machinery Ring Industry Standard JB/T8341999 1999-08-064 Q Double D Female @ e /4 2000-01-01 JB/T834±1999||tt| |e This standard is a revision of B834--85 "Technical Requirements for Hot Recommended Low-Voltage Electrical Appliances". The technical content of the revised JB/T834--1999 is consistent with JB834-85. According to the requirements of GB/T1.1-1993.GB/T1.3-1997, pre-education and citation standards have been added, and appropriate adjustments have been made to academic standards and writing formats. This standard will replace JB834-85 starting from the implementation of II. This standard is proposed and administered by Guangzhou Electrical Equipment Research Institute. This standard is sponsored by Guangzhou Electrical Equipment Research Institute, Shanghai Electrical Equipment Research Institute, and Tianjin Electrical Equipment Research Institute. The main drafters of this standard are: Wu Yizhou, Wei Zhuyun, Zhao Sijie, Yameiyun, Guo Hongfang. This standard is entrusted to Guangzhou Electrical Equipment. Keqing Research Institute is responsible for explaining: 1 1 scope G20P xEe/ Portuguese JB/T8341999 JB83485 this standard It stipulates the climate protection types and usage environmental conditions, technical requirements, test methods, acceptance test marks, packaging and storage recommendations for tropical plastic low-voltage electrical appliances. What is not specified in this standard shall comply with the provisions of the corresponding ordinary low-voltage electrical appliance standards. This standard applies to dielectric zone type low-voltage electrical appliances. 2 Reference standards The provisions contained in the following standards constitute provisions of this standard before they are cited in this standard. At the time of standard comparison, all adopted versions are valid and all standards will be revised. Parties using this standard should explore the possibility of using the latest versions of the following standards. GB/T 2423.4---1993 GB/T2423.16--1990 GB/T2423.17—1993 GB/T 4942.2—1993 GB /T 13126—1991 Basic Environmental Testing Procedures for Electrical and Electronic Products Test Db: Alternating Heat Protection Test Method (eqvIEC60068--2-30: 1980. and 1985 amendments) Basic Environmental Testing Procedures for Electrical and Electronic Products Test J :Long-term test method (eqvIEC60068---2---10:1988) Basic environmental test procedures for electrical and electronic products Test Ka: Salt test method (eqvIEC60068--2-l:1981)| |tt||Teardown resistance level of low-voltage electrical appliance enclosures General technical conditions for tropical protective packaging of machinery industry products GB/T 14048.1---1993 JB/T4159-1999 Low-voltage switchgear General principles for and control equipment (egYEC60947-1:1988) General technical conditions for tropical electrical products 3 Types of climate protection and environmental conditions of use 3.1 The protection types of tropical low-voltage electrical appliances are divided into: a) Humid tropical zone Type "TH\; b) Tropical type "TA\; ), moist heat plastic "LE" 3.2 The operating environmental conditions of tropical type low-voltage electrical appliances are shown in Table 1 . 1999-08-06 2000-01-01 1 serial number 1 3 .4.||tt ||s 6 2www.bzxz.net Air temperature Cable range versus humidity % Climate protection type||tt| |Environmental parameters sea dial ma year's best year's lowest annual average monthly average The most painful (hottest month) Guopingma Maximum sun source difference JB/T8341999 Table! Wet tropical type TH Below 3000 40 5 25 35 35 The most mixed month, the average maximum relative degree of confusion The driest month, the average minimum relative humidity| | tt | It is settled by the supply and demand parties. 2) Refers to the monthly average minimum temperature of the month being 25℃. 3) Refers to the monthly average maximum temperature of the month being 40%. 4) Special considerations are required when ordering. 4 requirements 4.1 Humid tropical low-voltage electrical appliances Non-tropical type TA 1000 and below 501:||tt ||- 5 30 45 40 30 10 (40 hours) ) Yes Yes Dry, lake heat type 1000 and below 50 - 30 45|| tt||40 30 95 (25 hours) 2 10 (40 hours)) xiang yes yes 4.1.1 The heating temperature rise limits of the contacts, soft connections, conductive screws and insulated coils of all levels of humid tropical low-voltage electrical appliances shall not exceed the current standards of the corresponding ordinary low-voltage electrical appliances, 4.1.2 The setting temperature of the bimetal thermal protection device of humid tropical low-voltage electrical appliances is set according to the object to be protected. 4.1.2.1 Protect the motor at 40℃. 4.1.2.2 Protect wires and cables at 35℃. Note: If the registered customer has special requirements, they should be discussed with the manufacturer when ordering. 4.1.3 Humid tropical low-voltage electrical appliances should have certain moisture resistance, that is, the products should meet the following requirements after passing the alternating condensation heat test in 5.1 of this standard. 4.1.3.1 The insulation resistance of the product should comply with the requirements in Table 2. Table 2 Determined voltage U V U.560 60≤660 660U≤800 800 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.