title>HG/T 21507-1992 Unified regulations on the depth of content of power design and construction drawings for chemical enterprises (Figure) - HG/T 21507-1992 - Chinese standardNet - bzxz.net
Home > HG > HG/T 21507-1992 Unified regulations on the depth of content of power design and construction drawings for chemical enterprises (Figure)
HG/T 21507-1992 Unified regulations on the depth of content of power design and construction drawings for chemical enterprises (Figure)

Basic Information

Standard ID: HG/T 21507-1992

Standard Name: Unified regulations on the depth of content of power design and construction drawings for chemical enterprises (Figure)

Chinese Name: 化工企业电力设计施工图内容深度统一规定(图)

Standard category:Chemical industry standards (HG)

state:in force

Date of Implementation:2001-01-01

standard classification number

Standard ICS number:71.010

Standard Classification Number:Engineering Construction>>Raw Materials Industry, Communications, Broadcasting Engineering>>P72 Petrochemical, Chemical Engineering

associated standards

Publication information

other information

Introduction to standards:

HG/T 21507-1992 Unified regulations on the depth of content of power design and construction drawings for chemical enterprises (Figure) HG/T21507-1992 standard download decompression password: www.bzxz.net

Some standard content:

Industry Standard of the People's Republic of China
Unified Provisions on the Depth of Contents of Construction Drawings for Electrical Design in Chemical Enterprises
HG21507-92
Electrical Design Technology Center Station of the Ministry of Chemical Industry, First Design Institute of the Ministry of Chemical Industry
These regulations were proposed by the Electrical Design Technology Center Station of the Ministry of Chemical Industry, issued by the Infrastructure Department of the Ministry of Chemical Industry, and prepared by the First Design Institute
These regulations are applicable to the construction drawing design of large and medium-sized projects in chemical enterprises. For small enterprises or renovation projects of old enterprises, they can be appropriately simplified. For major foreign-related projects or foreign aid designs, they can be deepened accordingly when necessary.
This regulation is mainly based on the power supply, distribution and lighting commonly used in chemical electrical design, but the relevant detailed drawings (construction drawings are not included.
This regulation is revised on the basis of the original CD90A1-81. In this revision, there are major changes in combination with the needs of development.
After the promulgation of the new national standard, the Second Design Institute of the Ministry of Chemical Industry compiled the "Unified Regulations on Graphic and Text Symbols for Electrical Design of Chemical Enterprises", which should be followed in this regulation, but because the Chinese characters in the national standard are not enough, a part is supplemented. In order to adapt to the needs of development and facilitate international exchanges, the drawing format and representation method are different from the provisions of CD90.A11-81.
On the premise of adopting the equipment order specification, the content of the equipment table is appropriately simplified. 4.2.1
The revision adds a cable panel table, which is manufactured! The panel is returned to the construction unit, which is conducive to the construction 4.2.2 coke
on-site management and use.
4.2.3 Secondary circuit diagram There are more than two ways of representation. This time, power supply and distribution are represented in two different ways respectively, in order to provide two ways for the project to choose. In the specific project, one way or both ways can be specified.
4.2.4 The representation of the terminal table, power supply and distribution are also two different ways, either two ways coexist or one way is specified.
Preparation instructions
4.2.5 The civil engineering condition drawing of the substation was added in the revision, which is conducive to on-site construction. 1.3
In order to adapt to the future computer-aided design, in terms of the drawing size, computer drawing has been considered. This regulation only stipulates the design content, depth and expression method. There is no relationship between the drawings, and they are not used as the basis for determining the scheme and technical economy in the design. The participants in the preparation are Liu Guisheng, Wang Xijue, Fan Changqi, Wang Dazhi, Ye Wenjie, Shen Junhan, etc. Due to the time constraints and level limitations during the preparation process, please give more valuable suggestions for errors and inappropriateness.
Hua 1 Enterprise Power Design Construction Drawing Content Depth Unified Regulations HG21507 -·92
Instructions for the preparation of the power supply and exchange and distribution parts of the plant. Catalog of drawings for external power supply lines and road lighting in the whole plant (exchange and distribution) substation drawings.
Catalog of distribution drawings
Catalog of lighting, lightning protection and grounding drawings.
21507:4
Electrical Design Technology Center Station of Ministry of Chemical Industry. The First Design Institute of Ministry of Chemical Industry.
Technical Director of the Chief Editor.
Technical Reviewer.
Technical Management Director.
Technical Responsible.
Instructions for the preparation of the catalog of drawings for each part.
1. All electrical design drawings and tables of each main item should be included in this catalog of drawings. 2. The catalog of drawings should be arranged in sequence. For the instantaneous sequence of the various dimensions of the drawings, please refer to this catalog of drawings.
3. The drawings selected from this project design as reuse drawings and national standard atlases should be included in the catalog of drawings.
4. Drawings from other engineering designs or professional general drawings made by our institute as reused drawings should be included in the drawing catalog. 5. The drawing catalog should be written in turn and filled in sequentially without blank lines or alternate lines. The People's Republic of China
Industry Standard
First Design Institute of Sugar Chemical Industry Ministry
Chemical Industry
HG21507--92
Connecting lines should coincide with network lines
Part II of the District Power Supply Center and Substation Preparation Instructions (I) Preparation of this Several Principles of the Present Regulations
1 Graphic and text symbols shall be based on the Ministry of Chemical Industry's "Graphic Symbols for Electrical Drawings" and "General Rules for the Formulation of Text Symbols in Electrical Technology" 1.1 Graphic symbols in circuit diagrams, blood designed as a network system with a specific module, the module used is M=2.5mm. 1.2 The length of the rectangle side and the diameter of the circle should be designed as multiples of 2%. For smaller symbols, 1.5m, 1.0m, and 0.5m are used. 1.3 The distance between lines is at least 2m to meet the requirement of 2.5mm minimum character height. 1.4 Regardless of the size of the symbol, the point should be at the intersection of the network. 1.5 The length of the connection between the horizontal and vertical elements should be appropriate. According to the size of the drawing, the M multiple should be appropriately determined. The midpoint of the graphic symbol coincides with the midpoint of the network. This line can also be used. When the line distance is 3M, 5M, 7M, etc., use 2. The drawings in this compilation are not related to each other (except for those noted), and are not used as the basis for design technology and solutions. People's Republic of China
Industry Standard
Compiled by the First Design Institute of the Ministry of Chemical Industry
Plant Power Supply and Transformation and Distribution Part
Compilation Instructions
Ministry of Chemical Industry
HG21507-92
Sheet 1
3When two or more different expressions appear in the drawings, one can be selected [This now recommends the first one (A)]4 Civil engineering drawings are added to this compilation. The purpose is to benefit both the design and construction personnel, to improve the design quality and to cooperate with civil engineering construction. Therefore, it is stipulated that the formal construction drawings must include civil engineering drawings. Each institute can determine the degree of simplicity of the case according to the project situation and requirements (the country can archive it, but it will not be found on site)5 Notes on references in drawing:
In order to avoid duplication and simplify the representation methods in drawing, the following provisions are made:5.1 Simple enclosure examples
5.2 Section cutting lines
People's Republic of China
Industry standards
Prepared by the First Design Institute of the Ministry of Chemical Industry
Factory area power supply and transformer substation part
Preparation instructions
Ministry of Chemical Industry
Proportion example
HG21507-92
Sheet 2
5.3 Omitted letter examples:
(II) Digital labels and Auxiliary text symbol terminology representation: (see next page)
5.4 Dimension line representation
5.5 Cable tray, trough wiring plan and cross-section: Cable arrangement diagram
People's Republic of China
Industry standard
Compiled by the First Design Institute of the Ministry of Chemical Industry
Approved by the Ministry of Chemical Industry
Plant power supply and substation part
Preparation instructions
HG21507-
Preparation instructions for digital labels and text symbols) Substation exchange, true current circuit diagram digital label group considered in the past The habit of using should be corrected according to the requirements of the new national standard.) The terms and text symbols commonly encountered in daily design are also compiled and listed in the table below for use. The collection is not comprehensive and can be accumulated and supplemented in the design. 3) If the text symbols and terms do not conform to the national standard or departmental standard, the national standard or departmental standard shall prevail. The People's Republic of China
Industry Standard
Compiled by the First Design Institute of the Ministry of Chemical Industry
Approved by the Ministry of Chemical Industry
Guangzhou Power Supply and Transformation and Distribution Part
Compilation Instructions
HG21507--92
Page 4,||tt| |Text symbols
Transformers and rectifiers
Power transformers
Current transformers
Voltage transformers
Zero-sequence current transformers
Lighting transformers
Pulse transformers
Step-up transformers
Autotransformers
Isolation transformers
Silicon rectifiers
Adaptive rectifiers
Excitation regulators
Floating chargers
Deep chargers
Current limiting reactors
Chargers
Cabinets and panels,Boxes and tables
High-voltage switch
AC distribution panel
DC panel
Control solution
Signal panel
Power distribution box
Terminal box
Distribution device interval
Socket box
Lighting distribution box
Metering panel solution
Protection panel
Transformer protection panel
Generator protection panel
Line protection panel
Text symbols
Differential protection panel
Low-frequency load shedding panel
Security power distribution box
Accident lighting distribution box
Power automatic switching box
Capacitor cabinet
Simulation Panel
On-site switch box
On-site operation box
Protection device category
Overvoltage discharge device arrester
Current limiting with instantaneous action
Protection device
Current limiting with delayed action
Protection device
Current limiting protection device with instantaneous and delayed action
Fuse
Voltage limiting protection device
Current relay
Voltage relay
Grounding relay
Thermal relay
Gas relay
Power relay
Same wave relay
Differential protection relay
Distance protection Relay
Mixed relay
Out-of-step protection relay
Low voltage relay
Overvoltage relay
Zero sequence relay
Symbol
Contactor and control relay
Contactor
Forward and reverse contactor
Reversing contactor
Brake contactor
Excitation contactor
Closing circuit
Jumping circuit
Tripping coil
Arc extinguishing line diagram
AC/DC intermediate relay
Polarization relay
Reed relay
Time relay
Reverse current relay
Pulse relay Electrical appliances
Signal relay
Flash relay
Speed ​​relay
Circuit breakers
Circuit breakers
Air circuit breakers
Magnetic circuit breakers
Molded case circuit breakers (automatic switches)
Vacuum circuit breakers
Isolating switches
Fuse knife switches
Oil circuit breakers
Switch buttons
Control selection switch
Push button switch
Mercury switch
Torque switch
Character symbols
Emergency switch
Auxiliary switch
Horizontal switchbzxZ.net
Transfer switch
Technology Interlock switch type
Liquid level sensor
Pressure sensor
Position sensor
Rate sensor
Temperature sensor
Rotating motor type
Generator
Diesel generator set
Phosphorus exciter
Electric generator network
Uninterruptible power supply
Motor
Synchronous motor
Asynchronous motor
Fuse type
Fuse
Breakdown fuse
Drop fuse
Fast fuse
Resistors
Current limiting resistors
Photoresistors
Text symbols|| tt||Shunt
Meters
Ammeter
People's Republic of China
Industry Standard
Compiled by the First Design Institute of the Ministry of Chemical Industry
Voltmeter
Active power meter
Active watt-hour meter
Reactive watt-hour meter
Reactive power meter
Power factor meter
Electricity with maximum demand indication
Frequency meter
Tachometer
Temperature indicator
Percentage meter (opening meter)
Ammeter conversion switch
Voltmeter conversion switch
Signals
Light-emitting sign. Signal light
Red signal Light
Orange signal light
Yellow signal light
Green signal light
Blue signal light
Purple signal light
White signal light
Buzzer
Factory power supply and power distribution part
Preparation description
Approved by the Ministry of Chemical Industry
Text symbols
Installation method
Laying method
Wire pipe
Plastic pipe
Photographed along the top
Through the steel pipe and concealed along the wall
Connecting piece
Switching piece
HG21507-92
Standard number
Sheet 5
+WC ,WC
+wo,-wo
+wS,-wS
People's Republic of China
Industry standard
Compiled by the First Design Institute of the Ministry of Chemical Industry
Approved by the Ministry of Chemical Industry
Example of small busbar labeling
Control circuit power supply
Closing circuit power supply
Signal circuit power supply
Distribution device accident signal power supply
Notice signal power supply
Light signal
Accident signal
Notice signal
Distribution device (section 1) accident signal
Distribution device (section I) accident signal
(section I) notice sales number
(μ (section) warning signal
Jumping circuit disconnection signal
"Falling card not restored" light sign
AC voltage bus section
AC voltage bus section
AC voltage bus section
AC voltage bus section
AC voltage bus section ⅡI
Flash signal
Factory power supply and substation section
Preparation instructions
HG21507--92
Page 6
Line numbering and marking method
()Text labeling method for flat flip equipment For example: High-voltage switchgear, with AH, multiple cabinets are AH1, AH2...AHn. The low voltage switch panel is named with AA, and multiple cabinets are named with AA1, AA2, etc. AAn. The motor is named with the process position number, such as B103A, B10.3B, etc. For other boxes, columns, and tables, please refer to the Chinese character symbols in this compilation. (II) Internal line marking method
2.1 For example: AHI high voltage switch cabinet to B103A high voltage motor power cable is marked with AH1-B103A, and its control cable is AH1-B103AC2.2 The lines in the workshop are named with the equipment position number. The main circuit and control circuit are named with the equipment position number, such as: motor position number B103A
fan pull number
2.3 External lines: (high voltage equipment)
Main circuit B103A
Control circuit B103AC
Main circuit S-1
Control circuit S-1C
Between substations: Example 1AH 01-24H05, indicates the No. 1 high-voltage switchgear of 1# substation to the No. 5 high-voltage switchgear of 2# substation.
Between high-voltage switchgear and electrical equipment: For example, 1AH 02-ITM01, indicates the No. 2 high-voltage switchgear of 1# substation to the No. 1 transformer of 1# substation, AH 03-P101A indicates the No. 3 high-voltage switchgear of 1# substation to the P101 high-voltage motor,
2.4 Lighting circuit
For example, the U phase of the third circuit of the No. 1 lighting distribution box is represented as AL1-U3. Note: The voltage busbar numbers listed in the table are applicable to the situation where there is only one voltage in the substation. If there are several different voltage levels,Different numbers can be used before the letter mark of the motherboard to distinguish them. Phase sequence marking
1) Marking of specific conductors:
Power supply of AC system
Power supply of DC system
(2) Phase sequence marking of electrical equipment terminals: AC system
Protective grounding
Protective grounding and neutral line share one line
Neutral line
Middle line
Neutral line
People's Republic of China
Industry standard
Prepared by the First Design Institute of the Ministry of Chemical Industry
Wide-area power supply and power distribution part
Preparation instructions
Approved by the Ministry of Chemical Industry Proportion
HG21507 - 92
Page 7 1
Pole. Falling Type
Straight Pole Tower
Corner Seed Fall
Branch Pole Tower
Terminal Pole Tower
Tension Pole Tower
Double Column Support Tower
People's Republic of China
Industry Standard
Compiled by the First Design Institute of the Ministry of Chemical Industry
Approved by the Ministry of Chemical Industry
Wide Area Power Supply and Transformation and Distribution Part
Compilation Instructions
Standard No.
HG21507-92
Page 8 Zhang
People's Republic of China
Point standard
First Design Institute of Ministry of Chemical Industry
Ministry of Chemical Industry
External power supply lines and road lighting for the whole plant
Drawing catalog
Drawing number or number
External power supply lines and road lighting for the whole plant
Drawing catalog
Instructions
Equipment and material table
Power supply load table for the whole plant
Power supply system diagram for the whole plant
Boundary power supply line plan
(—)()
Cable tray number plan
Cable table
Cable distribution panel table
Example diagram of overhead external lines
Pole type schematic
Wide area road lighting plan
Reuse diagram
Electric Cable laying
10 and below overhead
Line installation
21507.2--1
2150:2--2
2150%.2-3
21502-4
2150:2-5
21507.2-6
21507.2--7
21 507.2-8
21507.2-9
21507.2--10
21507.2-11
Reuse or standard
Drawing.File number
National standard D164
National standard D162
HG21507-92
Natural folding
Number of sheets
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.