title>JB/T 5332.3-1991 Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 3: Flat power cables for electric submersible pumps - JB/T 5332.3-1991 - Chinese standardNet - bzxz.net
Home > JB > JB/T 5332.3-1991 Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 3: Flat power cables for electric submersible pumps
JB/T 5332.3-1991 Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 3: Flat power cables for electric submersible pumps
Basic Information
Standard ID:
JB/T 5332.3-1991
Standard Name: Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 3: Flat power cables for electric submersible pumps
This standard specifies the product varieties, technical requirements and tests of electric submersible pump flat power cables. This standard applies to flat power cables for electric submersible (including submersible and submersible brine) pump units with rated voltages of 3.6/6KV and below. The lower end of the cable is connected to the lead cable and the upper end is connected to the ground control cabinet. JB/T 5332.3-1991 Electric submersible pump cables with rated voltages of 3.6/6kV and below Part 3 Electric submersible pump flat power cables JB/T5332.3-1991 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China JB/T5332.3-1991 Electric submersible pump cables with rated voltage of 3.6/6kV and below Part 3 Published on June 28, 1991 Flat power cables for electric submersible pumps Implementation on July 1, 1992 Published by the Ministry of Machinery and Electronics Industry of the People's Republic of China Mechanical Industry Standard of the People's Republic of China Electric submersible pump cables with rated voltage of 3.6/6kV and below Part 3 Flat power cables for electric submersible pumps Subject content and scope of application This standard specifies the product varieties, technical requirements and tests of flat power cables for electric submersible pumps. JB/T 5332.31991 This standard applies to flat power cables for electric submersible (including submersible and submersible brine) pump units with rated voltages of 3.6/6kV and below. The lower end of the cable is connected to the lead-in cable, and the upper end is connected to the ground control cabinet. In addition to complying with the provisions of this standard, the cable shall also comply with the requirements of JB5332.1 "First General Provisions for Electric Submersible Pump Cables with Rated Voltages of 3.6/6kV and Below". Usage Characteristics Rated voltage U. /U is 1.8/3, 3.6/6kV. The long-term allowable operating temperature and the lower allowable ambient temperature of the cable conductor are as specified in Table 1. Flat cables are particularly suitable for occasions where the gap between the oil pipe and the casing is small. The bending radius is not less than 500mm when laying. The ambient temperature when laying polypropylene insulated cables should not be lower than -20℃. Table 1 WQPN10, WQPF10 WQPN12, WQPF12 WQYJN10 WQYJN12 WQEN10 WQEN12 WQEE10 WQEE12 WQEH10 WQEH12 WQEQ10 The cable models are shown in Table 2. 4 Specifications The specifications of the cables are shown in Table 1. Rated voltage 1991-06-28 approved by the Ministry of Machinery and Electronics Industry Number of cores Nominal cross-section 16.0, 20.0, 33.5, 42.5 Allowable working temperature Long-term full working temperature of cable conductor 20℃ insulation resistance Under consideration 1992-07-01implementation WQPN10 WQPF10 WQPN12 WQPF12 WQYJN10 WQYJN1 2 WQEN10 WQEN12 WQEE10 WQEE12 WQEH10 WQEH12 WQEQ10 Technical requirements JB/T5332.31991 Polypropylene insulation Nitrile rubber inner sheath Steel belt interlocking Mis-installed submersible pump Shoulder-shaped power cable Polypropylene insulation Nitrile polyvinyl fluoride compound inner sheath Bare steel belt interlocking Pin-mounted submersible pump Flat power cable Polypropylene insulation Nitrile rubber inner sheath Steel belt interlocking Armored Polyoxyethylene outer sheath Submersible sleeve pump Flat power cable Polypropylene insulation Nitrile polyoxyethylene compound inner sheath Steel belt interlocking installation PTFE outer sheath submersible oil pump flat power cable XLPE insulation butyl rubber inner sheath bare steel belt interlocking knot installation submersible oil pump flat power cable XLPE insulation butyl rubber inner sheath steel belt interlocking armored PE outer sheath submersible oil pump flat power cable EPDM insulation butyl rubber inner sheath bare steel belt interlocking pin installation submersible oil pump flat power cable EPDM insulation butyl rubber inner sheath steel belt interlocking mirror installation PE outer sheath submersible sleeve pump fan-shaped power cable EPDM insulation EPDM inner sheath bare steel belt interlocking armor submersible oil pump flat power cable EPDM insulation EPDM inner sheath steel belt interlocking armored PE outer sheath submersible sleeve pump flat power cable EPDM insulation sulfonated polyethylene inner sheath bare steel Flat power cable with interlocking armor for submersible oil pump, EPDM insulation, sulfonated polyethylene inner sheath, steel tape interlocking armor, polyethylene oxide outer sheath, submersible oil pump fan-shaped power cable, EPDM insulation, lead inner sheath, bare steel tape interlocking armor, submersible oil pump flat power cable, the cable structure dimensions are as specified in Table 3 Conductor nominal Rated voltage Insulation type Inner sheath standard Steel tape nominal Outer sheath standard Conductive wire core roots Number/single line nominal Nominal thickness Nominal sheath length}) 1/4.62 Lead inner sheath nominal thickness is 1.0mm, Note, 1) The technical requirements of the cable shall comply with the provisions of Table 4. Overall dimensions Bare armor 17×40 18 × 42 20 ×48 21×52 18 ×42 19 ×44 21×50 22 × 54 With outer sheath 23 ×46 24 ×48 26×54 27×58 24 ×48 25×50 27×56 28×60 DC resistance of conductor at 20℃ No plating The test shall be in accordance with the requirements of Table 4. Structural dimensions Insulation thickness Inner sheath thickness Oil-resistant cushion layer Clamping layer Overall dimensions Electrical properties Conductor resistancewwW.bzxz.Net Insulation resistance Voltage test Leakage current 4h high voltage test Cable physical and mechanical properties Insulation physical and mechanical properties Inner sheath physical and mechanical properties||t t||Special performance Sealing performance of stranded conductor High temperature and high pressure performance Bending performance of misplaced layer JB/T5332.31991 Comply with Article 4.2 of JB5332.1 and Article 5.1 of this standardComply with Article 4.3 of JB5332.1 and Article 5.1 of this standardComply with Article 4.5 of JB5332.1 and Article 5.1 of this standardComply with Article 4.6 of JB5332.1||tt| |Comply with Article 4.9.1 of GB2952 and JB5332.1Comply with Article 5.1 of this standard Comply with Table 3 of this standard Comply with Table 1 of this standard Comply with Article 4.10.9 of JB5332.1 Comply with Article 4.10.4 of JB5332.1 Comply with Article 4.10.10 of JB5332.1Comply with Articles 4.3.2 and 4.3 of JB5332.1. Article 3 is in compliance with Article 4.5 of JB5332.1 is in compliance with Article 4.106 of JB5332.1 is in compliance with Article 4.10.5 of JB5332.1 is in compliance with Article 4.10.11 of JB5332.1 Note: St is a periodic sampling test, this standard stipulates that it is 12 months, Additional notes: This standard is proposed and managed by Shanghai Cable Research Institute, Ministry of Machinery and Electronics Industry. Test type Test method GB2952 GB2951e4 GB3048.4 JB5332.1 Appendix J GB2951 GB2951 JB53321 Appendix E JB5332.1 Appendix F JB5332.1 Appendix G This standard was drafted by Shanghai Cable Research Institute of the Ministry of Machinery and Electronics Industry, Tianjin Cable Factory, Shenyang Cable Factory and other units. The main drafters of this standard are Diao Xiangpeng, Dou Zhongbo and Wang Guozhong. 3 People's Republic of China Mechanical Industry Standard Rated voltage 3.6/6kV and below Electric submersible pump cable Part 3 Electric submersible pump flat power cable JB/T5332.31991 Published by the China Academy of Mechanical Science Printed by the China Academy of Mechanical Science (No. 2, Shouti South Road, Beijing Postal Code: 100044) Print Sheet X/X K Number of Words XXXXXX Format 880×1230 Edition X, XX, 19XX Printing X, XX, 19XX Number of Prints 1-xXX Price XXX.XX Yuan XX-XXX Mechanical Industry Standards Service Network: http://www.JB.ac.cn66 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.