title>QB/T 2424-1998 Double-sided adhesive tape - QB/T 2424-1998 - Chinese standardNet - bzxz.net
Home > QB > QB/T 2424-1998 Double-sided adhesive tape
QB/T 2424-1998 Double-sided adhesive tape

Basic Information

Standard ID: QB/T 2424-1998

Standard Name: Double-sided adhesive tape

Chinese Name: 双面胶粘带

Standard category:Light Industry Standard (QB)

state:in force

Date of Release1998-12-28

Date of Implementation:1999-07-01

standard classification number

Standard Classification Number:General>>Marking, packaging, transportation, storage>>A82 Packaging materials and containers

associated standards

Procurement status:neq JIS Z 1528-1991

Publication information

publishing house:China Light Industry Press

Publication date:1999-07-01

other information

drafter:Zhou Dongliang, Shen Renyu, Dai Liqun, Cui Hansheng

Drafting unit:Shanghai Huiqun Chemical Co., Ltd.

Focal point unit:National Light Industry Packaging Standardization Center

Proposing unit:Industry Management Department of State Administration of Light Industry

Publishing department:State Bureau of Light Industry

Introduction to standards:

This standard specifies the product classification, technical requirements, test methods, inspection rules and marking, packaging, transportation and storage of double-sided adhesive tapes. QB/T 2424-1998 Double-sided Adhesive Tapes QB/T2424-1998 Standard download decompression password: www.bzxz.net
This standard specifies the product classification, technical requirements, test methods, inspection rules and marking, packaging, transportation and storage of double-sided adhesive tapes.


Some standard content:

Classification No. A82
Light Industry Industry Standard of the People's Republic of China
QB/T 2424—98
Double-sided Adhesive Tape
Published on 1998-12-28
Published by the State Bureau of Light Industry
Implementation on 1999-07-01
QB/T 2424—98
This standard is not equivalent to the Japanese Industrial Standard JIS21528—1991. Effective date: 3: According to the actual situation of our company, the inspection method adopts the relevant national standards of my country, and the inspection rules for adhesive tapes can be completed in detail. This standard is issued by the National Light Industry Administration. This standard is promoted by the National Center for Standardization of Industrial Packaging. The main drafting units of this standard are: Shangyou Huihua Chemical Co., Ltd., and the main drafting units of this standard are: Zhushan Special Mining Factory and Shanghai Huashe Pharmaceutical Printing Packaging Factory. The main drafters of this standard are Zhou Dongliang, Xirenxun, Dai Liqun, and Gai Sheng. Scope
Light Industry Standard of the People's Republic of China
Double-sided Adhesive Tape
QB/T2424-98
This standard specifies the production classification, technical requirements, test methods, format rules, markings, selection and selection of double-sided adhesive tapes. Note: The effectiveness of this standard is poor, and the substrate is uniform on both sides. Pressure-sensitive adhesive, a sheet-shaped tape made by sticking paper (with adhesive removed) between one or two sheets,
2 Referenced standards
The following standards contain provisions that constitute the text of this standard through reference in this standard. When this standard is released, the versions shown are valid, and all revisions will be revised. The parties using this standard should explore the possibility of using the latest version of the standard
GB2792-81
Pressure-sensitive adhesive tape 18. Peel channel measurement method QB7125-86 Dimensional adhesive thickness determination method Eddy current method GR4851-84
Pressure-sensitive adhesive tape adhesion test method
3 Product classification
3. 1 Types
Double-sided adhesive tapes are classified according to the substrate's dynamic viscosity test requirements (see Table 3), see Table 1!
The first and
The fourth (health)
The fifth
Approved by the State Bureau of Light Industry on December 28, 1998
Double-sided (non-woven)
Plastic
Foaming
Tensile viscosity
Implemented on July 1, 1999
3.2 Marking
B/2424-98
Production marks indicate the name, type (code), paper tube inner diameter, adhesive thickness, density and length. The name "double-sided adhesive tape" is represented by the code "DiS\ (Douhle side abbreviation) means: Example: DSAI
4 Technical requirements
4.1 Floor head ()
@76×0.10×5×20
Specifications (paper tube with light 7Glmrm, thickness 0.10mm, width Smm and length 20m)
Double-sided adhesive as the first protection product
A maximum of 1 joint is allowed for a length less than 25m, and only 2 joints can be arranged for more than 25m. When the length is high, the single piece length must be less than 2nt-
4.2 External dead
Age belt: The surface is obviously deformed and wrinkled, and the two monks are flat. 4.3 Observation
The specifications of the micro-station belt shall comply with the provisions of Table 2:
0.1 ~-heart.2
0.1--0.2 [
The thickness is allowed to be different.
The thickness refers to the difference in thickness after the isolator is removed.
The error of the model is 10--30bzxZ.net
30100
2Length. The difference can be agreed upon by the military. The allowable difference refers to Table 24.4 Physical properties
The physical properties of the adhesive tape shall comply with the requirements of Table 3. Paper has been
length difference
After storage test
NilUmmn
After heat resistance test
180°opening
900°opening
After delivery test
5 Test method
5.1 Test conditions
QB/T2424-9B
The appearance of the tape should be tested step by step.96
All inspections should be carried out at (232)°C and humidity of 0%--70%. The sample should be placed under this condition for more than 2h.
5.2 Sampling method
Under the conditions of 5.1, remove the outer layer of the tape roll and collect the samples according to the sample specifications required in each test.
5.3 Specifications 1
5.3.1 Depth
Use a vernier caliper to measure three locations on the double-sided adhesive tape at roughly equal intervals, and take the arithmetic average. 6.3.2 Length and joints
Pull the double-sided adhesive tape apart, and after 30 minutes of standing, use a steel ruler with a graduation of [cm to measure the entire length, and check the joint shape.
5.3.3 Take a photo of the 7125 for measurement
5.3.4 Diameter of the two cores
Use a vernier caliper to measure three locations on the inner diameter of the core at roughly equal intervals, and take the arithmetic average. 5.4 Appearance
5.4.1 Appearance shall be inspected by daily measurement and inspection.
5.4.2 Unroll the adhesive tape at a speed of about 300mz/s to check whether the material is torn, whether there is peeling or lack of glue. 5.6 Island strength test
The test of the strength is divided into normal state and storage test and carried out gradually. 5. 5.1 Normal state
According to the provisions of G2792, the sample is bonded to the test board, the isolation on the other side is removed, and a PET film (0.025mm thick) of the same size as the sample is pasted: 6 samples are used to test the first and second bonding surfaces.
5. 5.2 Storage test
QB/T7424·-98
The standard adhesive tape is placed in a test box with a temperature of (65±2) and a relative humidity of (8015)% for 48h. Then test according to the method of 5.5.1.
5.B Sustained Adhesion
The sustained adhesion test is carried out in three conditions: normal state, after heat resistance test, and after accelerated weather resistance test. 5.6.1 Strip state
Measure according to GB4B51. Glue the sample one to the test plate, remove the weak release paper on the other side, and put a PET film (0.025mm thick) of the same size as the sample on it. At room temperature of (23±2), add a load of 1000g. After 60min, remove the load and measure the displacement distance. Use 6 samples, and calculate the sustained adhesion of the two samples from 3 calibration samples. 5.6.2 After the required heat test
Glue the sample one to the test electrode two, put it into the (100) hot air ring type incubator for 4h, cool it in the room for 6min, and then test according to the method of S.6.1. 5.6.3 After the low temperature test, the sample is glued to the test blanket, and then exposed to the ultraviolet carbon reduction lamp type endurance test machine for 48 hours. After being taken out, it is cooled in the room for 6 minutes. 5.6.1 Method test 8 Inspection rules 6.1 Products must be approved by the quality inspection department of the manufacturer according to this standard and pass the inspection. The certificate of conformity shall be issued before they can leave the factory. 6.2 Sampling and division rules 6.2.1 Batch and sample preparation Products produced in the same batch, specification and column are considered as a batch. At least 3 boxes are randomly selected from each batch of products, and at least 3 rolls (9 rolls) are taken from each box for appearance and width inspection of the whole roll. 2 of which are length and thickness: Physical performance inspection
5.2.2 Determination of the rules
Company) Dimension inspection, when the number of unqualified integers exceeds 10% of the total number of samples, it is allowed to take double samples from the batch of products for re-inspection. If there are still more than 10% of the unqualified numbers, the batch of products is not qualified. b) During the appearance inspection, when the number of samples that do not meet this standard exceeds 10% of the total number of selected products, it is allowed to take double samples from the batch of products for re-inspection. If the number of samples that do not meet the water content standard still exceeds 10%, the batch of products is unqualified.
cDuring the physical performance test, if any item of a roll does not meet the requirements of this standard, double samples may be taken for short-term testing of the item. If there is still one item that does not meet the requirements of this standard, the product shall be deemed unqualified: 6.3 Acceptance and Partial Inspection
The user has the right to request the product quality to be inspected in accordance with this standard. When the user has objections to the product quality, the inspection and supervision agency agreed by both parties shall inspect the product in accordance with this standard. Marking, packaging, transportation, storage
7.1 Marking
7.1.1 The inner packaging of the product should have the following signs: a) Marking: b) Name of manufacturer. 1.2 Each box of adhesive tape should have the following signs: a) Trademark: b) Name and address of manufacturer: c) Adhesive tape mark, product quality grade: d) Number and quantity: d) Production return period or production batch number: d) Anti-pressure, anti-full, anti-west and other signs: d) Storage; h) Implementation standard.
7.2 Packaging
7.2.1 Inner packaging
OB/F2424—98
Each product shall be packed with transparent plastic tape. 7.2.2 Outer packaging
Product packaging shall be in cardboard boxes. The upper and lower layers shall be separated. The packing list shall be in compliance with the regulations. 1.3 Transportation
Products shall be handled with care during transportation and shall not be mixed with volatile agents. 7.4 Storage
7.4.1 Products shall be stored in a warehouse free of sunlight and temperature-controlled radiation at a temperature of -5 to 35°C and a humidity of less than 80%. To prevent deformation, products shall be stacked horizontally. 7.4.2 If the products are not stacked directly on the ground, the bottom shall not be deformed. 7.4.3 The product warranty period is 1 year from the date of production. 5
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.