title>JB 20014-2004 Medicinal boiling granulator - JB 20014-2004 - Chinese standardNet - bzxz.net
Home > JB > JB 20014-2004 Medicinal boiling granulator
JB 20014-2004 Medicinal boiling granulator

Basic Information

Standard ID: JB 20014-2004

Standard Name: Medicinal boiling granulator

Chinese Name: 药用沸腾制粒器

Standard category:Machinery Industry Standard (JB)

state:in force

Date of Release2004-02-05

Date of Implementation:2004-06-01

standard classification number

Standard ICS number:11.120.30

Standard Classification Number:Medicine, health, labor protection>>Pharmaceutical, safety machinery and equipment>>C92 pharmaceutical processing machinery and equipment

associated standards

Publication information

publishing house:China Planning Press

Publication date:2004-06-01

other information

drafter:Lin Xiaohua, Zhang Guoxiong

Drafting unit:Shanghai Far East Pharmaceutical Machinery General

Focal point unit:Pharmaceutical Equipment Industry Standards Committee

Proposing unit:China Pharmaceutical Equipment Industry Association

Publishing department:National Development and Reform Commission

Introduction to standards:

This standard specifies the classification and labeling, requirements, test methods, inspection rules and markings, instructions for use, packaging, transportation and storage of medicinal boiling granulators. This standard applies to medicinal boiling granulators that perform mixing, granulating, and drying in a boiling manner. JB 20014-2004 Medicinal boiling granulator JB20014-2004 standard download and decompression password: www.bzxz.net

Some standard content:

JB | |tt||Water chestnut type coating machine
Swing granulator
Released on 2004-02-05
Implemented on 2004-06-01
National Development and Reform Commission Release
ICS11.120.30
C92
JB
Pharmaceutical Machinery Industry Standard of the People's Republic of China JB20014—2004
Medicinal Boiling Granulator||tt ||Fluidbedgranulatorforpharmaceutics2004-02-05 Release
2004-06-01 Implementation
National Development and Reform Commission Release
Previous
1 Scope
2| |tt||Normative reference documents
3 Classification and marking
4 Requirements..
5 Test methods
6 Inspection rules
7 Marks, Instructions for use, packaging, transportation and storage
Appendix A (Normative Appendix) Equipment sealing performance test method 8
times
JB20014—2004
JB20014-2004| |tt||Foreword
This standard is based on (Good Manufacturing Practice for Drugs) and GB/T1.1-2000 "Standardization Work Guidelines Part 1: Standard Structure and Writing Rules", GB/T1. 2-2002 "Standardization Work Guidelines Part 2: Methods for Determining the Content of Normative Technical Elements in Standards" revised the "Medicinal Boiling Granulator" and made the following major changes to the relevant technical content in this standard. : a) The model marking has been modified according to the requirements of YY/T0216 "Method for Comprehensive Control of Pharmaceutical Machinery Product Models". b) The quoted standard has been modified
c) Due to the different specific gravity of various materials, the production capacity in the product model is specified as the batch feeding amount of blank particles. d) For the sealing performance of the no-load test equipment, the original standard method of measuring the static pressure value at the air inlet has a certain error. This time modifications were made when revising this standard.
The material yield test stipulates in detail the standard materials, rated feeding amount and a certain proportion of the formula for the blank particle test. Finally, the yield rate is calculated by the formula.
f) Granular finished product content test, which uses a standard sieve to determine the quality of fine powder and then uses a formula to calculate the final granular finished product content. g) Added the contents of factory inspection and type inspection and the determination rules of product inspection. h) Appendix A of this standard is a normative appendix. This standard is proposed by China Pharmaceutical Equipment Industry Association. This standard is under the jurisdiction of the Pharmaceutical Equipment Industry Standardization Technical Committee. This standard was drafted by: Shanghai Far East Pharmaceutical Machinery Factory. The main contributors to this standard are Lin Xiaohua and Zhang Guoxiong. Previous releases of this standard: The first release was CB12254-1990 (Note: This standard was announced in 1992 by the former State Administration of Technical Supervision in the "National Standards Cleanup and Rectification Announcement (1)" and adjusted to an industry standard). 1 Scope
Medicinal boiling granulator
JB 20014——2004
This standard specifies the classification and marking, requirements, test methods, and inspection rules of medicinal boiling granulators and logos, instructions for use, packaging, transportation and storage.
This standard applies to medicinal boiling granulators (hereinafter referred to as granulators) that mix, granulate, and dry materials in boiling form. 2 Normative reference documents
The provisions in the following documents become provisions of this standard through reference in this standard. For dated reference documents, all subsequent amendments (excluding corrigenda) or revisions do not apply to this standard. However, parties that reach an agreement based on this standard are encouraged to study whether the latest versions of these documents can be used. Version. For undated referenced documents, the latest edition applies to this standard. GB/T191 Packaging, storage and transportation pictorial marking www.bzxz.net
GB3836.1 Electrical equipment for explosive gas environments Part 1: General requirements GB5226.1-2002 Mechanical safety mechanical electrical equipment Part 1 General technical conditions GB/T9969.1 General instructions for industrial products GB/T10111 Random sampling method using random numbers GB12309 Industrial corn starch
GB/T13306 Labeling
General technical conditions for mechanical and electrical product packaging
GB/T 13384
9 Metal cutting machine tool noise sound pressure level measurement method GB/T 16769
YY/T0216 Pharmaceutical machinery product model preparation method Pharmaceutical Good Manufacturing Practice (1998 revised edition) National Medical Products Administration 3 Classification and labeling
3.1 Type
Powdered materials are granulated by spraying binder in a closed fluidized bed. 3.2 Classification
Granulators are divided into two types: ordinary type and explosion-proof type. It is composed of the following parts: a) collection chamber;
b) spray chamber:
c) raw material container;
d) air purification and heating device; ||tt| |Air supply device:
e)
JB20014—2004
f) control box system;
g) adhesive conveying device;
h ) explosion-proof device.
3.3 model
3.3.1 The granulator model should comply with the regulations of YY/T0216. 3.3.2 Model preparation:
LF mouth O
Improved design sequence number (A, B)
Specification code: Determine the characteristic code according to the input amount of each batch (kg batch) ( B - Explosion-proof type: Ordinary type without code) Type code (F - boiling)
Product function code (L - granulator)
3.3.3 Marking example:
LFB120A| |tt||The first improved design
The feeding capacity of each batch is 120kg
Explosion-proof type
Boiling
Granulator
4 requirements|| tt||4.1 Working conditions
4.1.1 The boiling air used in the granulator should be filtered by coarse, medium and high-efficiency filters. 4.1.2 The spray air used in the granulator should meet the purification requirements of level 100000. 4.2 Material requirements
4.2.1 All parts in the granulator that are in direct contact with the material should be made of non-toxic, corrosion-resistant materials that do not chemically react or adsorb with the material, and should comply with the "Pharmaceutical Production Relevant provisions in the "Quality Management Standards" (1998 revised edition). 4.2.2 The sealing rings, hinges, and pipes (non-metallic) selected in the granulator should be made of non-toxic, odorless, particle-free and corrosion-resistant materials.
4.2.3 The filter bag in the collection chamber must be anti-static. 4.3 The granulator should have good sealing performance, and its p,≥0.9p②4.4 The granulator should be equipped with a static elimination device in the working area to effectively lead static electricity to the grounding point. Its grounding resistance should be greater than 1002.
①P is the vacuum gauge reading after turning off the vacuum media. ②P is the vacuum gauge reading after turning on the vacuum operation. 6
4.5 The effect maker must be equipped with a side-type or neck-type rapid explosion relief device. 4.6 The explosion-proof granulator should have the following increased safety design structural requirements: JB 20014-2004
4.6.1 Set a switch at the explosion vent device to turn on the explosion vent instantly, cut off the power supply and close the air inlet and outlet door Pipe valve. 4.6.2 Various buttons, indicator lights, instruments and motors at the granulator operation site should be explosion-proof components or pneumatic components. 4.7 The material yield of the granulator should not be less than 97%. 4.8 The particle size of the granulator should be no less than 90% in the range of $1.25mm~0.20mm (16 mesh~80 months). 4.9 There should be no abnormal sound or jamming during normal operation of the granulator, and its load noise sound pressure level should not exceed 80dB(A). 4.10 Electrical safety performance requirements
4.10.1 The continuity of the protective grounding circuit of the electrical system shall comply with the provisions of 19.2 in CB5226.1-2002. 4.10.2 The insulation resistance of the electrical system should comply with the provisions of 19.3 in GB5226.1-2002. 4.10.3 The withstand voltage of the electrical system should comply with the regulations in 19.4 of CB5226.1-2002. 4.10.4 The protective grounding circuit of the electrical system should comply with the provisions of 8.2 in CB5226.1-2002. 4.10.5 The buttons of the electrical system should comply with the provisions of 10.2 in GB5226.1-2002. 4.10.6 The indicators and displays of the electrical system should comply with GB5226.The provisions of 10.3 in 1-2002. 4.10.7 The wiring of the electrical system should comply with the provisions of Chapter 14 of CB5226.1-2002. 4.10.8 The markings, warning signs and project codes of the electrical system shall comply with the provisions of Chapter 17 of CB5226.1-2002. 4.10.9 In addition to the above safety performance requirements, explosion-proof granulators should also comply with the relevant regulations in GB3836.1. 4.11 Appearance
4.11.1 The welding surface should not have defects such as cracks, undercuts, pores, and defects such as slag and spatter that affect the appearance. 4.11.2 The outer wall of the granulator should be flat and smooth, with no obvious scratches or unevenness. 4.11.3 The surface roughness Ra value of the internal and external surfaces of the granulator that is in contact with materials should not be greater than 0.8m. 5 Test methods
5.1 Working conditions
Filters that can meet 100,000-level purification requirements should be used, and their quality certificates should be provided by the supplier. 5.2 Material quality
The materials used in the granulator must provide a material certificate. 5.3 Equipment sealing performance test
Equipment sealing performance test shall be carried out in accordance with Appendix A. 5.4 Static elimination device test
Use a resistance meter to measure the resistance between each component of the granulator and the ground. 5.5 Explosion relief device test
Inspect the explosion relief device of the granulator by visual inspection. 5.6 Explosion-proof granulator structural requirements test
5.6.1 The safety valve device that automatically closes the intake and exhaust can be tested by manually opening the explosion relief device. 5.6.2 Visually inspect the explosion-proof components or pneumatic components of the granulator. 5.7 Material yield test
7
JB 200142004
5.7.1 Material: use 0.12mm~0.15mm fine powder and corn starch in compliance with GB12309. 5.7.2 Feeding volume: Calculated based on the rated feeding volume of not less than 80% of various specifications of granulators. 5.7.3 Formula: Use 50% corn starch, 10% dextrin and 40% sugar powder to conduct a blank particle test. 5.7.4 Granulate twice according to the granulation process. The total mass of the material collected in the second time and the total mass of the input materials are converted into anhydrous components, and the material yield is calculated according to formula (1).
Finished product quality
Material yield ((%) = material quality before technology 1005.8 Finished product quality test
5.8.1 Carry out the test according to the steps of 5.7.1~5.7.3. ·(1)
5.8.2 Sampling 10% of the finished product for testing, the sample should be taken from the center, and then use a standard sieve of 40.20mm (80 mesh) to sieve the fine powder quality. According to the formula (2) Calculate finished product content. : Finished product content (%)
5.9 Load noise test
Total mass of finished product ($0.20mm) Fine powder mass. (2
Total mass of finished product| |tt||Use a sound level meter to test the load noise of the granulator according to the relevant provisions of CB/T16769. 5.10 Electrical safety performance test
5.10.1 The continuity, insulation resistance and endurance of the protective grounding circuit of the electrical system. The voltage test shall be carried out in accordance with the provisions of 19.2, 19.3 and 19.4 in GB5226.1-2002 respectively. 5.10.2 The protective grounding circuit, buttons, indicators and displays, wiring, markings, warning signs and project codes of the electrical system shall be The safety test of the electrical device of the explosion-proof granulator shall be carried out in accordance with the provisions of 8.2, 10.2, 10.3, Chapter 14 and Chapter 17 of GB5226.1-2002 respectively, and the appearance quality of 5.12 shall be carried out.
5.12.1 Visually inspect the appearance quality of the granulator. 5.12.2 Comparative inspection of the surface roughness of the inner wall of the granulator. 5.13 No-load test
Each unit. All granulators should undergo a no-load test of no less than 1 hour to confirm that the sealing performance, static elimination device, explosion venting device, and electrical safety performance of the granulator should meet the requirements. 5.14 Load test
After the granulator passes the no-load test, a load test is performed to confirm that the material yield, finished product content, and noise should meet the requirements. 6 Inspection Rules
6.1 Each granulator must be inspected by the inspection department of the manufacturing unit. Only after passing the test can it leave the factory. 6.2 The granulator is divided into factory inspection and type inspection | Quality certificate. 8
Project Category
General Performance
Main Performance
Table 1 Factory Inspection Items
Inspection Items
JB 20014 —2004
4.2.4.4.4.6.1,4.6.2,4.10.4,4.10.5,4.10.6.4.10.7.4.10.8,4.10.9,4.114.3, 4.10.1, 4.10 .2, 4.10.3
6.2.1.2 If the granulator is found to be unqualified during the inspection process, it shall be allowed to be returned for repair and re-inspection. If it is still unqualified, the product shall be judged to be unqualified.
6.2.2 Type inspection
6.2.2.1 Type inspection is a comprehensive assessment of product quality. That is, all requirements specified in the standard are inspected. 6.2.2.2 Type inspection shall be carried out when one of the following situations occurs: a) When trial production and appraisal of new products:
b) When there are major improvements in the structure, materials and processes of the product: c) Resume after 2 years of long-term suspension of production During production: d) When required for quality certification or arbitration.
6.2.2.3 Sampling inspection:
The prototypes for type inspection shall be randomly selected from 10% (at least one) of the products that have passed the factory inspection for testing according to the method specified in GB/T10111.
6.2.2.4 Judgment Rules
If the continuity of the protective grounding circuit of the electrical system, insulation resistance, withstand voltage, material yield and finished product contain any failure during the type inspection, it will be judged as unqualified. . If one of the other items is unqualified, the unqualified item should be retested twice. If it is still unqualified, the product will be deemed to have failed the type inspection.
7 Logo, instructions for use, packaging, transportation and storage 7.1 The nameplate of each granulator should be fixed on an obvious part of the machine. The size and technical requirements of the nameplate should comply with the relevant regulations of GB/T13306. The content of the nameplate is as follows:
a) Product name:
b) Product model and specifications;
c) Production capacity, total power, rated voltage: d) Name of manufacturer;|| tt||e) Product number and release date:
f) Product standard number.
7.2 Instructions for use
The product instructions for use shall comply with the relevant provisions of CB/T9969.1. 7.3 Packaging Marks
The words and marks on the outer wall of the packaging box should be clear and have the following content: a) Product model and name;
b) Arrival and departure station names:
9
15mm fine powder and corn starch in compliance with GB12309. 5.7.2 Feeding volume: Calculated based on the rated feeding volume of not less than 80% of various specifications of granulators. 5.7.3 Formula: Use 50% corn starch, 10% dextrin and 40% sugar powder to conduct a blank particle test. 5.7.4 Granulate twice according to the granulation process. The total mass of the material collected in the second time and the total mass of the input materials are converted into anhydrous components, and the material yield is calculated according to formula (1).
Finished product quality
Material yield ((%) = material quality before technology 1005.8 Finished product quality test
5.8.1 Carry out the test according to the steps of 5.7.1~5.7.3. ·(1)
5.8.2 Sampling 10% of the finished product for testing, the sample should be taken from the center, and then use a standard sieve of 40.20mm (80 mesh) to sieve the fine powder quality. According to the formula (2) Calculate finished product content. : Finished product content (%)
5.9 Load noise test
Total mass of finished product ($0.20mm) Fine powder mass. (2
Total mass of finished product| |tt||Use a sound level meter to test the load noise of the granulator according to the relevant provisions of CB/T16769. 5.10 Electrical safety performance test
5.10.1 The continuity, insulation resistance and endurance of the protective grounding circuit of the electrical system. The voltage test shall be carried out in accordance with the provisions of 19.2, 19.3 and 19.4 in GB5226.1-2002 respectively. 5.10.2 The protective grounding circuit, buttons, indicators and displays, wiring, markings, warning signs and project codes of the electrical system shall be The safety test of the electrical device of the explosion-proof granulator shall be carried out in accordance with the provisions of 8.2, 10.2, 10.3, Chapter 14 and Chapter 17 of GB5226.1-2002 respectively, and the appearance quality of 5.12 shall be carried out.
5.12.1 Visually inspect the appearance quality of the granulator. 5.12.2 Comparative inspection of the surface roughness of the inner wall of the granulator. 5.13 No-load test
Each unit. All granulators should undergo a no-load test of no less than 1 hour to confirm that the sealing performance, static elimination device, explosion venting device, and electrical safety performance of the granulator should meet the requirements. 5.14 Load test
After the granulator passes the no-load test, a load test is performed to confirm that the material yield, finished product content, and noise should meet the requirements. 6 Inspection Rules
6.1 Each granulator must be inspected by the inspection department of the manufacturing unit. Only after passing the test can it leave the factory. 6.2 The granulator is divided into factory inspection and type inspection | Quality certificate. 8
Project Category
General Performance
Main Performance
Table 1 Factory Inspection Items
Inspection Items
JB 20014 —2004
4.2.4.4.4.6.1,4.6.2,4.10.4,4.10.5,4.10.6.4.10.7.4.10.8,4.10.9,4.114.3, 4.10.1, 4.10 .2, 4.10.3
6.2.1.2 If the granulator is found to be unqualified during the inspection process, it shall be allowed to be returned for repair and re-inspection. If it is still unqualified, the product shall be judged to be unqualified.
6.2.2 Type inspection
6.2.2.1 Type inspection is a comprehensive assessment of product quality. That is, all requirements specified in the standard are inspected. 6.2.2.2 Type inspection shall be carried out when one of the following situations occurs: a) When trial production and appraisal of new products:
b) When there are major improvements in the structure, materials and processes of the product: c) Resume after 2 years of long-term suspension of production During production: d) When required for quality certification or arbitration.
6.2.2.3 Sampling inspection:
The prototypes for type inspection shall be randomly selected from 10% (at least one) of the products that have passed the factory inspection for testing according to the method specified in GB/T10111.
6.2.2.4 Judgment Rules
If the continuity of the protective grounding circuit of the electrical system, insulation resistance, withstand voltage, material yield and finished product contain any failure during the type inspection, it will be judged as unqualified. . If one of the other items is unqualified, the unqualified item should be retested twice. If it is still unqualified, the product will be deemed to have failed the type inspection.
7 Logo, instructions for use, packaging, transportation and storage 7.1 The nameplate of each granulator should be fixed on an obvious part of the machine. The size and technical requirements of the nameplate should comply with the relevant regulations of GB/T13306. The content of the nameplate is as follows:
a) Product name:
b) Product model and specifications;
c) Production capacity, total power, rated voltage: d) Name of manufacturer;|| tt||e) Product number and release date:
f) Product standard number.
7.2 Instructions for use
The product instructions for use shall comply with the relevant provisions of CB/T9969.1. 7.3 Packaging Marks
The words and marks on the outer wall of the packaging box should be clear and have the following content: a) Product model and name;
b) Arrival and departure station names:
9
15mm fine powder and corn starch in compliance with GB12309. 5.7.2 Feeding volume: Calculated based on the rated feeding volume of not less than 80% of various specifications of granulators. 5.7.3 Formula: Use 50% corn starch, 10% dextrin and 40% sugar powder to conduct a blank particle test. 5.7.4 Granulate twice according to the granulation process. The total mass of the material collected in the second time and the total mass of the input materials are converted into anhydrous components, and the material yield is calculated according to formula (1).
Finished product quality
Material yield ((%) = material quality before technology 1005.8 Finished product quality test
5.8.1 Carry out the test according to the steps of 5.7.1~5.7.3. ·(1)
5.8.2 Sampling 10% of the finished product for testing, the sample should be taken from the center, and then use a standard sieve of 40.20mm (80 mesh) to sieve the fine powder quality. According to the formula (2) Calculate finished product content. : Finished product content (%)
5.9 Load noise test
Total mass of finished product ($0.20mm) Fine powder mass. (2
Total mass of finished product| |tt||Use a sound level meter to test the load noise of the granulator according to the relevant provisions of CB/T16769. 5.10 Electrical safety performance test
5.10.1 The continuity, insulation resistance and endurance of the protective grounding circuit of the electrical system. The voltage test shall be carried out in accordance with the provisions of 19.2, 19.3 and 19.4 of GB5226.1-2002 respectively. 5.10.2 The protective grounding circuit, buttons, indicators and displays, wiring, markings, warning signs and project codes of the electrical system shall be The safety test of the electrical device of the explosion-proof granulator shall be carried out in accordance with the provisions of 8.2, 10.2, 10.3, Chapter 14 and Chapter 17 of GB5226.1-2002 respectively, and the appearance quality of 5.12 shall be carried out.
5.12.1 Visually inspect the appearance quality of the granulator. 5.12.2 Comparative inspection of the surface roughness of the inner wall of the granulator. 5.13 No-load test
Each unit. All granulators should undergo a no-load test of no less than 1 hour to confirm that the sealing performance, static elimination device, explosion venting device, and electrical safety performance of the granulator should meet the requirements. 5.14 Load test
After the granulator passes the no-load test, a load test is performed to confirm that the material yield, finished product content, and noise should meet the requirements. 6 Inspection Rules
6.1 Each granulator must be inspected by the inspection department of the manufacturing unit. Only after passing the test can it leave the factory. 6.2 The granulator is divided into factory inspection and type inspection | Quality certificate. 8
Project Category
General Performance
Main Performance
Table 1 Factory Inspection Items
Inspection Items
JB 20014 —2004
4.2.4.4.4.6.1,4.6.2,4.10.4,4.10.5,4.10.6.4.10.7.4.10.8,4.10.9,4.114.3, 4.10.1, 4.10 .2, 4.10.3
6.2.1.2 If the granulator is found to be unqualified during the inspection process, it shall be allowed to be returned for repair and re-inspection. If it is still unqualified, the product shall be judged to be unqualified.
6.2.2 Type inspection
6.2.2.1 Type inspection is a comprehensive assessment of product quality. That is, all requirements specified in the standard are inspected. 6.2.2.2 Type inspection shall be carried out when one of the following situations occurs: a) When trial production and appraisal of new products:
b) When there are major improvements in the structure, materials and processes of the product: c) Resume after 2 years of long-term suspension of production During production: d) When required for quality certification or arbitration.
6.2.2.3 Sampling inspection:
The prototypes for type inspection shall be randomly selected from 10% (at least one) of the products that have passed the factory inspection for testing according to the method specified in GB/T10111.
6.2.2.4 Judgment Rules
If the continuity of the protective grounding circuit of the electrical system, insulation resistance, withstand voltage, material yield and finished product contain any failure during the type inspection, it will be judged as unqualified. . If one of the other items is unqualified, the unqualified item should be retested twice. If it is still unqualified, the product will be deemed to have failed the type inspection.
7 Logo, instructions for use, packaging, transportation and storage 7.1 The nameplate of each granulator should be fixed on an obvious part of the machine. The size and technical requirements of the nameplate should comply with the relevant regulations of GB/T13306. The content of the nameplate is as follows:
a) Product name:
b) Product model and specifications;
c) Production capacity, total power, rated voltage: d) Name of manufacturer;|| tt||e) Product number and release date:
f) Product standard number.
7.2 Instructions for use
The product instructions for use shall comply with the relevant provisions of CB/T9969.1. 7.3 Packaging Marks
The words and marks on the outer wall of the packaging box should be clear and have the following content: a) Product model and name;
b) Arrival and departure station names:
9
1Type inspection is a comprehensive assessment of product quality. That is, all requirements specified in the standard are inspected. 6.2.2.2 Type inspection shall be carried out when one of the following situations occurs: a) When trial production and appraisal of new products:
b) When there are major improvements in the structure, materials and processes of the product: c) Resume after 2 years of long-term suspension of production During production: d) When required for quality certification or arbitration.
6.2.2.3 Sampling inspection:
The prototypes for type inspection shall be randomly selected from 10% (at least one) of the products that have passed the factory inspection for testing according to the method specified in GB/T10111.
6.2.2.4 Judgment Rules
If the continuity of the protective grounding circuit of the electrical system, insulation resistance, withstand voltage, material yield and finished product contain any failure during the type inspection, it will be judged as unqualified. . If one of the other items is unqualified, the unqualified item should be retested twice. If it is still unqualified, the product will be deemed to have failed the type inspection.
7 Logo, instructions for use, packaging, transportation and storage 7.1 The nameplate of each granulator should be fixed on an obvious part of the machine. The size and technical requirements of the nameplate should comply with the relevant regulations of GB/T13306. The content of the nameplate is as follows:
a) Product name:
b) Product model and specifications;
c) Production capacity, total power, rated voltage: d) Name of manufacturer;|| tt||e) Product number and release date:
f) Product standard number.
7.2 Instructions for use
Product instructions for use shall comply with the relevant provisions of CB/T9969.1. 7.3 Packaging marks
The words and marks on the outer wall of the packaging box should be clear and have the following content: a) Product model and name;
b) Arrival and departure station names:
9
1Type inspection is a comprehensive assessment of product quality. That is, all requirements specified in the standard are inspected. 6.2.2.2 Type inspection shall be carried out when one of the following situations occurs: a) When trial production and appraisal of new products:
b) When there are major improvements in the structure, materials and processes of the product: c) Resume after 2 years of long-term suspension of production During production: d) When required for quality certification or arbitration.
6.2.2.3 Sampling inspection:
The prototypes for type inspection shall be randomly selected from 10% (at least one) of the products that have passed the factory inspection for testing according to the method specified in GB/T10111.
6.2.2.4 Judgment Rules
If the continuity of the protective grounding circuit of the electrical system, insulation resistance, withstand voltage, material yield and finished product contain any failure during the type inspection, it will be judged as unqualified. . If one of the other items is unqualified, the unqualified item should be retested twice. If it is still unqualified, the product will be deemed to have failed the type inspection.
7 Logo, instructions for use, packaging, transportation and storage 7.1 The nameplate of each granulator should be fixed on an obvious part of the machine. The size and technical requirements of the nameplate should comply with the relevant regulations of GB/T13306. The content of the nameplate is as follows:
a) Product name:
b) Product model and specifications;
c) Production capacity, total power, rated voltage: d) Name of manufacturer;|| tt||e) Product number and release date:
f) Product standard number.
7.2 Instructions for use
Product instructions for use shall comply with the relevant provisions of CB/T9969.1. 7.3 Packaging Marks
The words and marks on the outer wall of the packaging box should be clear and have the following content: a) Product model and name;
b) Arrival and departure station names:
9
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.