This standard specifies the type, model and basic parameters, technical requirements, inspection rules, test methods, marking, packaging, etc. of small submersible electric pumps. This standard is applicable to single-phase or three-phase single-stage or multi-stage small submersible electric pumps with a flow rate of 1.5~250 cubic meters/h, a head of 3~130m, and a power of 0.12~11kW. JB/T 8092-1996 Small submersible electric pumps JB/T8092-1996 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China JB/T8092-96 Small Submersible Electric Pump Published on September 3, 1996 Ministry of Machinery Industry of the People's Republic of China Implementation on July 1, 1997 JB/T8092-96 1 Scope 2 Reference Standards 3 Type, Model and Basic Parameters 4 Technical requirements 5 Test methods 6 Inspection rules 7 Marking, packaging Appendix A Modification and determination of efficiency (Appendix to the standard) JB/T8092-96 This standard is a revision of GB947788 "Types and basic parameters of small submersible electric pumps" and ZBK2000289 "Technical conditions for small submersible electric pumps", and the original two standards are merged into one. During the revision, the still applicable contents in GB947788 and ZBK20002-89 were retained, and the following modifications were made according to the development situation: 1. Small submersible electric pumps are a whole composed of pumps and motors, so this standard specifies the efficiency of electric pumps and their tolerances. 2. This standard removes some technical requirements that are unnecessary or impossible to assess, such as: requirements for vibration, noise, minimum torque of motors, etc. 3. This standard adds varieties and specifications of small submersible electric pumps, and allows the development of products that meet actual use requirements according to the provisions of the standard; 4. This standard lists the provisions on pump efficiency as Appendix A (Appendix to the standard), and merges the pump efficiency curves in GB9477-88 from A and B into one; 5. This standard unifies the test methods to implement GB/T1278591 "Test Methods for Submersible Electric Pumps", and specifies the length of the test cable; 6. This standard implements GB/T1.1-1993, and makes adjustments to the standard format. This standard shall replace GB9477-88 and ZBK20002-89 from the date of implementation. Appendix A of this standard is the appendix of the standard. This standard is proposed and managed by the National Technical Committee for Agricultural Machinery Standardization. The responsible drafting unit of this standard: Irrigation and Drainage Machinery Research Institute of Jiangsu University of Science and Technology. The participating drafting units of this standard: Irrigation and Drainage Machinery Research Institute of China Agricultural Mechanization Science Research Institute and Shanghai Electric Science Research Institute. The main drafters of this standard: Ma Xinhua, Cao Wulin, Xu Anxiang, Zhang Qiaoying, I 1 Scope Machinery Industry Standards of the People's Republic of China Small Submersible Electric Pumps JB/T8092-96 This standard specifies the types, models and basic parameters, technical requirements, inspection rules, test methods and markings, packaging, etc. of small submersible electric pumps. This standard applies to single-stage or multi-stage small submersible electric pumps (hereinafter referred to as electric pumps) with a flow rate of 1.5~250m/h, a head of 3~130m, and a power of 0.12~11kW single-phase or three-phase. 2 Reference standards The provisions contained in the following standards constitute the provisions of this standard through reference in this standard. When this standard is published, the versions shown are valid. All standards will be revised, and parties using this standard should explore the possibility of using the latest version of the following standards. GB191—90 GB75587 GB1971—80 GB923988 GB5013.2—85 GB/T12785—91 JB/T6880.1~6880.393 JB/T759194 Type, model and basic parameters 3.1 Type||tt| |Packaging, storage and transportation pictorial marking Basic technical requirements for rotating electrical machines Motor line terminal marking and rotation direction Determination of allowable imbalance of rigid rotor balance quality Rubber insulated flexible cables with rated voltage of 450/750 and below Part 2 General purpose rubber sheathed flexible cables Test methods for submersible electric pumps Castings for pumps General technical conditions for starting elements of small single-phase asynchronous motors 3.1.1 The electric pump is vertical and the pump is coaxial with the motor. 3.1.2 The enclosure protection level of the electric pump is IPX8. 3.1.3 The quota of the electric pump is a continuous quota based on the continuous working system S1). 3.1.4 The electric pump rotates counterclockwise when viewed from the water inlet. 3.2 Model 3.2.1 Model Indication Method The model of the electric pump consists of uppercase Latin letters and Arabic numerals, and its meaning is as follows: Approved by the Ministry of Machinery Industry on September 3, 1996 Implementation on July 1, 1997 3.2.2 Type Characteristics JB/T8092-96 0-0/0-0 Type characteristics are indicated by the following uppercase Latin letters: D single-phase motor (three-phase motor is not marked) Y-oil-filled motor: S-water-filled motor (kilowatt-hour motor is not marked): Rated power, kw Number of stages (single-stage is not marked) Specified total head, mWww.bzxZ.net Specified flow, m/h Type Characteristics|| tt||Small submersible electric pump XThe pump is below the motor (downward pump type (the pump is above the motor, that is, the upward pump type, not specified): R—swirl impeller; Lchannel impeller; K—open impeller (closed impeller not specified) NBuilt-in electric pump (external electric pump not specified); BSemi-built-in electric pump. 3.2.3 Marking example The specified flow rate is 25m/h, the specified total head is 24m, the rated power is 3kW, and the three-phase water-filled two-stage upward pump type small submersible electric pump is marked as: QS25-24/2-3 The specified flow rate is 15m/h, the specified head is 10m, and the rated power is 0.75kW. The single-phase dry single-stage downward pump type small submersible electric pump is marked as: QDX15-10 -0.75 The specified flow rate is 40m/h, the specified head is 45m, the rated power is 9.2kW, and the three-phase dry single-stage upper pump internal small submersible electric pump is marked as: QN40-45-9.2 3.3 Basic parameters 3.3.1 When the power frequency is 50Hz, the voltage is 380V (three-phase) 220V (single-phase) and the specified conditions of use, the basic parameters of the single-stage electric pump shall comply with Table 1, the basic parameters of the multi-stage electric pump shall comply with Table 2, and the basic parameters of the QXL and QXR electric pumps shall comply with the provisions of Table 3. The specified speed of the electric pump in Table 1 and Table 2 is 2860r/min3.3.2 When the basic parameters such as the flow rate and head of the electric pump do not meet the requirements of Tables 1 to 3, the specified efficiency of the electric pump shall be in accordance with Appendix A (Standard 3.33 When the electric pump adopts an open impeller, the specified efficiency of the electric pump is allowed to decrease by 0.02, and the specified total head is allowed to decrease by [1-(0.02/specified efficiency of the electric pump) times the specified head. 3.3.4 When the electric pump is built-in or semi-built-in, the specified efficiency of the electric pump is allowed to decrease by 0.02, and the total specified head is allowed to decrease by [1-(0.02 specified efficiency of the electric pump) times the specified head. JB/T8092—96 Specified efficiency of electric pump JB/T8092—96 Table 1 (continued) Specified efficiency of electric pump JB/T8092-96 Table 1 (end) Specified efficiency of electric pump JB/T 8092—96 Electric pump specified efficiency JB/T8092—96 Table 2 (continued) Electric pump specified efficiency JB/T8092—96 Table 2 (continued) Electric pump specified efficiency JB/T8092—96 Table 2 (continued) Electric pump specified efficiency JB/T8092—96 Table 2 (continued) Electric pump specified efficiency Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.