SJ/T 10547-1994 Blank Detailed Specification for Compact Fluorescent Lamps SJ/T10547-1994 Standard Download Decompression Password: www.bzxz.net
Some standard content:
Electronic Industry Standard of the People's Republic of China SJ/T10547—94 Blank detail specification for compact fluorescent lamps Blank detail specification for compact fluorescent lamps1994-08-08 Issued Implemented on 1994-12-01 Issued by the Ministry of Electronics Industry of the People's Republic of China Electronic Industry Standard of the People's Republic of China Blank detail specification for compact fluorescent lamps Biank detail specification for compact fluorescent lampsSJ/T10547—94 This blank detailed specification stipulates the basic principles for formulating the detailed specification for compact fluorescent lamps. It is used together with SJ/T10546 "General Specification for Special Fluorescent Lamps" to constitute all the requirements for compact fluorescent lamps. The format adopted by the detailed specification and the contents included should be consistent with this blank detailed specification. Notes on the front page of a blank detailed specification: The numbers between the square brackets on the front page of a blank detailed specification shall correspond to the following: Identification of the detailed specification [1] Name of the body authorized to issue this detailed specification. [2] Number and year of the detailed specification. [3] Number and year of the general specification. [4] Number and year of the blank detailed specification. Identification of fluorescent tubes: [5] Brief description of the fluorescent tube, cathode type, starting method, etc. [6] Model of the fluorescent tube. [7 Outline drawing with main dimensions. Ministry of Electronics Industry of the People's Republic of China Approved on August 8, 1994 Implemented on December 1, 1994 Blank detailed specification homepage SJ/T10547—94 Performance (not for inspection) 1.1 General performance 1.1.1 Quality 1.2 Starting characteristics 1.2.1 Starting voltage 1.2.2 At starting 1.3 Electrical parameters 1.3.1 Lamp power 1.3.2 Lamp terminal voltage 1.3.3 Working current 1.3.4 Preheating current 1.4 Light parameters 1.4.1 Luminous flux 2 Information 2.1 Mark 2.1.1 Product mark Manufacturer's trademark; Product model, Manufacture date. Packaging mark Manufacturer’s name and trademark; Product name and model; Number of this standard; Number of lamp tubes; SJ/T10547—94 Minimum value Nominal value Maximum value The packaging box should have signs such as “Handle with care” and “Keep away from moisture” as specified in GB191 “Picture mark for packaging, storage and transportation”. 2.2 Ordering information The ordering party should fill in the following information on the order form: a. Required product model: Number and release date of detailed specifications; Others. 2.3 Related documents Packaging, storage and transportation pictorial signs SJ/T10546 General specification for special fluorescent tubes 2.4 Additional information (not for inspection) Note: "*" indicates the content that should be filled in the detailed specifications. 3 2.5 Installation location 3 Test items and inspection requirements SJ/T10547-94 The test conditions and inspection requirements are given in the table below. According to the requirements of the specific model, the test conditions used should be specified in the detailed specifications and be consistent with the corresponding test method provisions in SJ/T10546. Unless otherwise specified, all referenced article numbers should use the corresponding SJ/T10546 article numbers. Group A - Batch Inspection All tests are non-destructive (ND) reference Inspection or test Group A1 Appearance quality Group A2 Starting voltage Starting time Group A3 Insulation resistance SJ/T10546 Test conditions As specified As specified As specified As specified Minimum value All tests are non-destructive (ND) reference Inspection or test Group B31 Electrode leads of lamp tube||tt ||Fixed mass Structural dimensions | Assembly deviation of lamp holder and glass tube B2 grouping Lamp power Lamp terminal voltage SJ/T10546 Test conditions As per regulations As per regulations As per regulations As per regulations Minimum value Maximum value As per regulations Inspection requirements Batch inspection Maximum value As per drawing requirements As per regulations Note: "" indicates the content that should be filled in the detailed specification. Inspection ·Unit Inspection or test B3 group Luminous flux of lamp Color coordinates of lamp: Target value Color tolerance SJ/T10546 Test conditionsWww.bzxZ.net As specified As specified SJ/T10547-94 Minimum value Maximum value Note: "" indicates the content to be filled in the detailed specification. Group C—Periodic Inspection Those with mark (D) are destructive tests Inspection or test Group C1 Fire and flame retardancy (D) Leakage distance of lamp holder Temperature rise of lamp holder Moisture resistance of lamp holder Group C2 Life (D) SJ/T10546 Note: ①p——Test period (in months). ②nSample size (in pieces). ?cNumber of qualified judgments. 4 Delayed delivery According to regulations According to regulations According to regulations According to regulations According to regulations According to regulations Minimum value Maximum deviation According to regulations According to regulations According to regulations According to regulations According to regulations According to regulations For lamps that have passed the quality consistency inspection and have a storage period of more than 12 months, the following items must be re-inspected before delivery. Appearance quality; b. Starting voltage. Additional remarks: This specification is under the jurisdiction of the Electronic Standardization Institute of the Ministry of Electronics Industry. This specification was drafted by the Standardization Institute of the Ministry of Electronics Industry and Weihai Beiyang Electric Group Corporation. The main drafters of this standard are Gao Fucai, Lai Wanqiong and Wang Haijian. Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.