This standard specifies the compilation of shipboard low-voltage switchgear and electric control device models. This standard applies to shipboard low-voltage switchgear and electric control devices with voltages of 1000V AC and below or 1200V DC and below. JB/T 9613-1999 Shipboard low-voltage switchgear and electric control device JB/T9613-1999 standard download decompression password: www.bzxz.net
Some standard content:
JB/T9613-1999 Foreword This standard is a revision of ZBU04-001-89 "Model Compilation Method for Marine Low Voltage Switchgear and Electric Control Devices" based on GB/T1.1-1993 and GB/T1.3-1997. This standard is consistent with the original standard ZBU04001-89. This standard replaces ZBU04001-89 from the date of implementation. Appendix A and Appendix B of this standard are both appendices of the standard. This standard is proposed and managed by Shanghai Electric Science Research Institute. This standard is drafted by Shanghai Electric Science Research Institute. Drafters of this standard: By the law The original standard was first issued in March 1989. Easy Niu Standard Nanny Program name Program address exet General grab Niu Dao Ke F:exev Niu Dao Niu To Operation. Already. Status Ready to open 192.168.5.1. Daily start and end Machinery Industry Standard of the People's Republic of China Marine low-voltage switchgear and controlgear assemblies Model compilation method Compilation of type for low-voltage switchgear and controlgear assemblies in ships This standard specifies the compilation of the model of marine low-voltage switchgear and controlgear assemblies. JB/T 96131999 Replaces ZBU04001-89 This standard applies to marine low-voltage switchgear and electric control devices with voltages of AC 1000V and below or DC 1200V and below. Principles of model compilation The model represents the main characteristics of the product and serves as a simplified code for the product for design, production, ordering and other work. 2.2 The naming of the model should be concise and non-repetitive. 2.3 The model consists of uppercase Chinese phonetic letters (hereinafter referred to as letters) and Arabic numerals (hereinafter referred to as numbers). The letters should be selected according to one of the following principles: a) The first letter of the Chinese phonetic letter of the product name represented is used; b) If it is difficult to adopt principle a), the non-first letter of the Chinese phonetic letter of the product name represented is used; c) If it is really difficult, letters that are not related to the phonetic letter can be selected. 3.1.1 The model of marine low-voltage switchgear is represented by a structural feature code, a functional code, a marine code, a design code, a specification code and an additional code. The model consists of a structural feature code, a functional code, a marine code, a design code, a specification code and an additional code. The additional code is represented by a single letter, as shown in Table 1. Approved by the State Bureau of Machinery Industry on August 6, 1999 and implemented on January 1, 2000. Structural feature. Panel (board). JB/T.96131999. Table 1. Structural feature code. The functional code of marine low-voltage switchgear is represented by two letters, and the main functional codes are shown in Table 2. Table 2 Function code A (shore power device) C (charging and discharging device) D (light control device) F (distribution device) S (test device) Z (main distribution device) Note: If the product has multiple functions, the main function is given priority. 3.1.3 Function code The marine code of marine low-voltage switchgear is represented by the number 9. Design code and specification code are represented by numbers. Chinese Pinyin Navigation light Flash light Signal light Electrical use AC power distribution DC power distribution 3.1.5 Additional code: In a variety, additional codes can be used to represent different auxiliary features or to represent each component in a set of devices. Additional codes can be represented by letters or numbers. The letters and numbers are not given fixed meanings in advance. They can be compiled according to the specific conditions of each series of products, proposed by the manufacturer, and submitted to the competent authority for review. 3.1.6 Model example: 10A marine AC distribution box FJ Additional code Specification code: 10A Design code Marine code Function code: AC distribution device Structural feature code: Box 3.2 Method of indicating the model of marine low-voltage electric control device JB/T9613-1999 Model is represented by structural feature code 3.2.1 The structural characteristic code of marine low-voltage electric control device is represented by one letter, as given in Table 1. 3.2.2 The category code of marine low-voltage electric control device is represented by one letter, as given in Table 3. .Table 3 Category code Category code B(BENG) C(CANG) D(DUO) G(GUO) H(HUO) J(JIA) K(KONG) L(LENG) M(MAO) N(DAN) s(sUI) T(TING) U(ZHU) Others For cabin||tt ||Energy machine Boiler Cargo crane (crane) Driver's cab Air conditioning Refrigeration Motor, mooring, winch, mooring Desalination Electric heating Sewage treatment Boat crane Main engine Ventilation Propulsion Air compressor JB/T9613-1999 3.2.3 The function code is represented by one letter and is given in Table 4. Table 4 Function Code Function Code P(PIN) W(WEN) X(XIN) Y(YAO) Note: If the product has multiple functions, the main function is given priority. 3.2.4 The marine code of marine low-voltage electric control devices is represented by the number 9. 3.2.5 Design code and specification code are represented by numbers. Including Magnetic starter Auto-coupling step-down starter Centralized control Automatic control Frequency-sensitive starter Star-delta starter 3.2.6 Additional code: In a variety, when it is necessary to indicate its different auxiliary features or to indicate its components in a set of devices, additional codes can be used to indicate it. Additional codes can be represented by letters or numbers. The letters and numbers are not given fixed meanings in advance and can be compiled according to the specific conditions of each series of products. 3.2.7 Model example: 100A marine cargo crane control box + 3.3 Supplementary provisions for model compilation Specification code: 100A Design code Marine code Function code: General Category code: For cargo crane Structural feature code: Box The codes listed in the tables of this standard can be supplemented by the product model management unit according to the product development situation and reported to the competent authority for record. 4 Model application method The model application method for marine low-voltage switchgear and electric control equipment shall be in accordance with Appendix A (Appendix to the standard), and the model application card shall be in accordance with Appendix B (Appendix to the standard). JB/T9613-1999 Appendix A (Appendix to the standard) Method for applying for models of marine low-voltage switchgear and electronic control devicesA1After accepting the task of developing new products, the research and development unit (industry, research institute or joint design group) can apply to the product management unit for the trial product model. A2When applying for the trial product model, the design task book, main technical indicators and product development plan schedule must be provided, and the trial product model will be issued by the management unit. A3 If the trial production plan cannot be completed as scheduled or the development task is cancelled for some reason, the reason should be explained and reported to the product unified unit. A4 After the trial production of the new product is completed and identified, prepare a document and attach the following information to apply for the official product model to the product unified unit: a) Product technical conditions and their preparation instructions; b) Electrical schematic and appearance diagram: c) System wiring diagram and instruction manual: d) Component list; e) Product identification certificate; f) Trial product model approval document; g) Two product model application cards for marine low-voltage switchgear and electronic control device (with product photos) A5 After receiving the above information, the product purchasing unit will issue the official product model (one model application card will be returned after the unified unit stamps it). A6 When the technical parameters, appearance dimensions and installation dimensions are affected by product modifications, a separate model application procedure is required. The application card for the model of marine low-voltage switchgear and electronic control device shall be printed uniformly by the product management unit, and the research and development unit shall fill in the following information according to the content listed on the application card: Product name JB/T9613-1999 Appendix B (Standard Appendix) Contents of the application card for marine low-voltage switchgear and electronic control device model Application card for marine low-voltage switchgear and electronic control device model is officially issued Model and meaning (to be filled in by the responsible unit) Marine low-voltage electric control device Marine low-voltage switching device Trial product model Enterprise model recommended by the requesting unit Explanation: Additional code Specification code Design code Marine code Function code Category code Structural feature code| |tt||Additional codeWww.bzxZ.net -Specification code Design code Marine code Function code -Structural feature code No.: Product overview photo Product features and main features Main technical parameters of the product Product development plan and completion date List of technical documents submitted by the applicant||tt ||Data name Product technical conditions and preparation instructions Electrical source diagram and appearance diagram System wiring diagram and instruction manual Component list Product identification certificate Applicant (official seal) JB/T9613-1999 Year, month, day This card is in duplicate, one copy is kept in the relevant unit, and one copy is returned to the application unit. Issuing unit (official seal) Year, month! Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.