This standard specifies the pressure test requirements for ship power piping and ship system piping. This standard applies to ship power piping and ship system piping. CB/T 3616-1994 Pipeline pressure test requirements CB/T3616-1994 Standard download decompression password: www.bzxz.net
Some standard content:
Shipbuilding Industry Standard of the People's Republic of China CB/T3616-94 Requirements for Pipeline Pressure Test Published on April 11, 1994 Published by China State Shipbuilding Corporation Implementation on October 1, 1994 Shipbuilding Industry Standard of the People's Republic of China Requirements for Pipeline Pressure Test 1 Subject Content and Scope of Application This standard specifies the pressure test requirements for ship power piping and ship system piping. This standard applies to ship power piping and ship system piping. 2 Test Quality Requirements 2.1 The pressure gauge used for the pressure test shall be calibrated and qualified and within the effective period of use. CB/T3616—94 Classification number: U50 2.2 The strength test of the pipe shall be carried out in the workshop after processing; the tightness test of the pipeline shall be carried out after installation on board. Leakage inspection shall be carried out on each flange and pipe joint. There shall be no leakage. During the tightness test, the pipeline shall be separated from the machinery or equipment. 2.3 All pipes for Class 1 and Class I piping systems, as well as steam pipes, water pipes, compressed air pipes and fuel pipes with a design pressure greater than 0.35MPa shall be subjected to hydraulic strength test after manufacturing and before being wrapped with insulation materials or coated. 2.4 When Class I and Class 1 piping systems are connected by butt welding during installation on board, a hydraulic test shall be carried out after welding in accordance with the provisions of the table; if the entire circumference of the butt weld is inspected by ultrasonic or radiographic inspection and the quality is good, the hydraulic test may be exempted. 2.5 The compressed air pipeline should be tested for air tightness under working pressure. The test time of the air pipeline (without air bottle) shall not be less than 10 minutes, and the pressure drop shall not be greater than 1%; the test time of the air pipeline and the air bottle together shall not be less than 2 hours, and the pressure shall not drop significantly. 2.6 After the pipeline pressure test, the water in the pipe shall be drained and blown dry with compressed air. 2.7 Grade 1 and Grade Ⅱ pipelines and pipelines that need to be inspected by ship inspection shall be stamped with a qualified steel stamp after passing the strength test. 2.8 Records should be kept during the hydraulic strength test and tightness test. Pressure test requirements The hydraulic strength test and tightness test of the pipeline (excluding the suction pipeline) shall be carried out in accordance with the provisions of the following table. Pipeline test pressure Hydraulic strength test Fuel pipeline Lubricating oil pipeline Fresh water and seawater pipeline Compressed air pipeline Steam pipeline 300℃ ≥300℃ Pressure (in workshop) China State Shipbuilding Corporation 1994-04-11 approved test medium Oil or water Tightness test pressure (after loading on board) Test medium 1994-10-01 implemented Hydraulic oil Boiler feed water Boiler discharge Boiler pressure Fuel oil pipeline Oil tank heating pipeline Bilge water and ballast water pipeline Deck drainage pipeline Sewage drain pipeline Air pipeline Domestic water pipeline Condensate pipeline Water fire extinguishing pipeline Automatic water sprinkler fire extinguishing pipeline Bottle head valve to distribution Carbon nitride Distribution valve pipeline Automatic distribution valve to Spray head pipeline Halon fire extinguishing pipeline Foam fire extinguishing pipeline Inert gas pipeline Note: - 3.2 Others Pipeline design pressure. CB/T3616-94 Hydraulic strength testbzxZ.net Pressure (in the workshop) 1.5p, but not less than 0.4 Test medium Oil or water Tightness test pressure (after loading on board) 1.25p, but need not||exceed p+0.7 1.0p, but not more than 1.6 1.5p, but not less than 0.4 Test medium and the hull structure tightness test test together , can be exempted The hydraulic strength test in the workshop and the tightness test after loading on board of various pump suction pipelines are both 0.4MPa; the test medium is water. 3.2.14 After loading, if the local pipe section cannot be tested for tightness, the tightness requirements during actual use should be guaranteed. Additional remarks: This standard is proposed by China State Shipbuilding Corporation. CB/T361694 This standard is under the jurisdiction of the 603rd Institute of China State Shipbuilding Corporation. This standard was drafted by Qiuxin Shipyard. ★The main drafters of the standard are Dai Weidong and Pan Xueying. 3 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.