title>GB/T 3029-1996 Technical requirements for marine ventilation accessories - GB/T 3029-1996 - Chinese standardNet - bzxz.net
Home > GB > GB/T 3029-1996 Technical requirements for marine ventilation accessories
GB/T 3029-1996 Technical requirements for marine ventilation accessories

Basic Information

Standard ID: GB/T 3029-1996

Standard Name: Technical requirements for marine ventilation accessories

Chinese Name: 船用通风附件技术条件

Standard category:National Standard (GB)

state:in force

Date of Release1996-03-28

Date of Implementation:1996-11-01

standard classification number

Standard ICS number:Shipbuilding and offshore structures>>Shipbuilding and offshore structures in general>>47.020.90 Marine ventilation, air conditioning and heating systems

Standard Classification Number:Ship>>Ship Pipe Accessories>>U54 Marine Ventilation Accessories

associated standards

alternative situation:GB 3029-1982

Publication information

publishing house:China Standards Press

ISBN:155066.1-13037

Publication date:2004-04-01

other information

Release date:1982-04-15

Review date:2004-10-14

Drafting unit:Jiangnan Shipyard

Focal point unit:National Technical Committee for Standardization of Marine Vessels

Publishing department:State Bureau of Technical Supervision

competent authority:China State Shipbuilding Corporation

Introduction to standards:

This standard specifies the technical requirements, test methods, inspection rules, marking and packaging of marine ventilation accessories. This standard applies to all types of marine ventilation accessories. GB/T 3029-1996 Technical requirements for marine ventilation accessories GB/T3029-1996 Standard download decompression password: www.bzxz.net

Some standard content:

1Cs 47. 020. 90
National Standard of the People's Republic of China
GB/T 3029--1996
Technical conditions for marine ventilation accessories
Specification af parts for ships' ventilation1996-03-28Promulgated
Implementation on 1996-11-01
Promulgated by the State Bureau of Technical Supervision
National Standard of the People's Republic of China
Technical conditions for marine ventilation accessories
Speclricatlon of parisFor ships'ventalatknTopic content and scope of application
GB/r3029-1996
Generation: GR3G29-82
This standard specifies the technical requirements, test methods, inspection specifications and parts for marine ventilation accessories. This standard is applicable to all kinds of ventilation accessories. 2 Reference standard
B8923 Ladder copper surface corrosion level and steel grade electric new details
CB*/Z$2 Intelligent alloy anode panel home chemical department
3 Technical requirements
Super ventilation accessories installation diagram see Figure 1
Building air duct
Ventilation direction or ventilation head: 2 Adjustment: 3-Suspension type: small ventilation: 5-Pipe flange. Self-%-Fireproof courtyard or ventilation room: a water fan 3.7 Service type air conditioner clear cattle allowable burrs, mosquitoes, the surface should be smooth 3.3 The joints should be uniform and must not have defects such as rust, air induction, bite, welding drops, condensation, etc. 3.4 Steel ventilation accessories should be rust-proofed (large castings and processing can be removed, and the user can send it to the %2 level requirements in GB8323) 3.5 Refers to the variable The steel parts of the chain are treated with zinc Cn/764, and the degree of plating is not more than 3Ur1. After the parts are processed, the B~/Z32 is provided with an oxidation treatment, and the National Technical Supervision and Administration approved it on March 28, 1996 and implemented it on 11-01, 1996. 3-6 Pay attention to the long-term operation of the lifting and rotating parts, and the parts of the parts should be light and effective. The parts of the parts should be grease-free. 3.B can be airtight, and the ventilation parts and parts that need to maintain the ventilation should have good sealing performance. This performance is tested quickly. After the test, there will be no evidence of mixing. 3.9 The ventilation warehouse has enough water to make the plate have a positive water test: after the test, there should be no mixing conditions. 3 .1 Fire and smoke resistance is the fire resistance requirement of S1AS convention. It is necessary to carry out fire resistance test. It has good insulation performance (maximum 20M0) power distribution monitoring performance (total pressure V) and self-closing performance to resist fire. It can work normally in various environments during operation.
3.11 After the product is connected, the upper layer (including zinc, oxidation, etc.) must be removed: the product must be stored or packaged before it is exposed to the outside.
4 Test method
41 Water pressure test
The water pressure test should be carried out according to the test pressure requirements in Table 1. The water test lasts for 5m. The test results should meet the requirements of %! 1
Yu Du name analysis
Through R. And the ditch
According to the city method, the gas capacity is increased
Through K . Commercial, wine wind head
There is a filling state diagram of the damper
Discussion
For the original
Design
For ventilation and ventilation not listed in this table, it can be or its own equipment, etc. The original small state is selected for the test level 4.2 Flushing test
During the flushing test, the diameter of the flushing spray shall not be less than 2.5m. The water spray pressure shall not be less than 1.25MPE, the flushing distance shall not exceed 1.5m, and the flushing time shall be 3mm. The test results shall meet the requirements of 3.5. 4.3 Fire resistance
Fire resistance limit test shall be continued. There is a fire breaker temperature of 70°C and the fire resistance limit test of the damper shall be within 50°C. When the temperature reaches 141°C, the system shall be gradually activated and the closing case shall be activated. 5 Inspection rules
5.1 Appearance inspection shall comply with the requirements of 3.2 and 3.3. 5.2 Inspection or performance inspection shall comply with the requirements of 3.6. 5.3 Test the parts according to the first requirement. If defects are found during the test, they shall be repaired and disinfected, and then tested again. If the pressure of the test is to be re-tested, it shall be increased by 20% compared with the first test. If defects are found again in the second test, the parts shall be reported to the warehouse for inspection. 5.4 After acceptance, the manufacturer shall issue a certificate of quality. 6 Marking and packaging
6.1 The attachment shall have the following signs:
Manufacturer name or logo;
Machine name:
± Production batch number
d. Qualified food. bzxz.net
6.2 Packaging
GB/T3029—1996
When the package is packed, the items should be marked carefully and all the items should be sealed. Additional notes:
The three items in this standard are the total cost of the old standard
Fengchang Standard is produced by Jiangnan Shipyard.
This standard was drafted by Jiangyu Shipyard.
The main drafters of the standard are Chang Anli, Hui Wenteng, Ding Yuye
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.