JB/T 5219-1991 Industrial Thermocouple Types, Basic Parameters and JB/T5219-1991 Standard Download Decompression Password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China JB/T5219-91 Industrial Thermocouple Types, Basic Parameters and Dimensions 1991-07-09 Issued Ministry of Machinery and Electronics Industry 1992-07-01 Implementation Mechanical Industry Standard of the People's Republic of China Industrial Thermocouple Types, Basic Parameters and Dimensions Subject Content and Scope of Application JB/T5219-91 This standard specifies the types, basic parameters and dimensions of detachable and armored industrial thermocouples (hereinafter referred to as thermocouples). This standard applies to thermocouples with one or two pairs of thermocouples, protective tubes and wiring devices or other additional devices. 2 Thermocouple Type The shape of the protective tube and the type of the fixing device of the thermocouple are shown in Table 1. Table 1 Protective tube Fixed installation Type of installation Approved by the Ministry of Machinery and Electronics Industry on July 9, 1991 Implemented on July 1, 1992 Protective tubewww.bzxz.net Fixed installation Type of installation Sleeve or sleeve JB/T5219—91 Continued Table 1 Protective tube Fixed installation Type of installation Sleeve or sleeve JB/T5219—91 Continued Table 1 Protective tube Fixed installation Type of installation JB/T 5219---91 Continued Table 1 Protective tube Fixed installation Type JB/T5219-91 Continued Table 1 Note: In the figure of No. 5 in the table, the size of M is M20×1.5. The user is also allowed to negotiate with the manufacturer to manufacture other sizes. 2.2 Types of thermocouple wiring devices Thermocouple wiring devices have the following types: no junction box, simple type; protective type (anti-drainage, anti-splash, anti-spray, etc.); flameproof type; plug-in type. Basic parameters and dimensions 3.1 Basic parameters of thermocouples The types, graduation numbers and temperature ranges of thermocouples are shown in Table 2. Table 2 Thermocouple type Platinum 10%-Platinum Platinum 30%-Platinum 6% Nickel-chromium-nickel-silicon Nickel-chromium-silicon-nickel-silicon Nickel-chromium-copper-nickel Copper-copper-nickel Iron-copper-nickel Graduation number Dimension 1:10 AA section enlargement Temperature range ℃ 0~16 00 600~1700 200~+1200 -200~+1200 -200~900 200~+350 -40~+750 Note: The actual operating temperature range of the thermocouple is related to the material of the protection tube, the measured medium, the diameter of the couple wire, etc., and should be specified by the manufacturer in the instruction manual. 3.2 Protection tube diameter and insertion depth. Protection tube diameter d and insertion depth L are shown in Table 3. 5 8.3 Exposed length Exposed length (L.) is shown in Table 4. Shape of protection tube Straight, tapered (fixture) Tapered (welding) Diameter of protection tube JB/T5219—91 Type of wiring device Socket wiring box Other wiring boxes Socket wiring box Other wiring boxes Note: The L in the figure of No. 5 in Table 1 also allows the user to negotiate with the manufacturer to manufacture other sizes. 3.4 Length of right-angle protection tube The length LA and LB of the right-angle protection tube of the thermocouple can be 500 or 750mm. 3.5 Dimensions of fixture The dimensions of different types of fixtures are shown in Tables 5, 6 and 7. Table 5 Fixed installation Type of installation Hand S Wrench S Protective tube Diameter d M27×2 M33×2 M33×2 Exposed length L. 30.50,100 100,150,200,250 20,30,50 50,100,150,200 Note: ①For the thermocouple of the socket junction box, when the diameter of the protective tube is 12mm, the connection thread of M22×1.5 can be selected. ②For special purposes, the production of fixtures of other sizes is allowed after consultation between the user and the manufacturer. 6 Nominal pressure Fixed installation Setting type Fixed installation Setting type Schematic diagram Movable ferrule thread Fixed ferrule thread JB/T5219---91 Protective tube diameter Protective tube diameter $55014 Nominal pressure Nominal pressure 2.5Normal pressure Fixed installation Setting type Fixed ferrule flange Movable ferrule flange 3.6Dimensions of terminal box outlet hole Dimensions of terminal box outlet hole are shown in the figure below. Additional Notes: JB/T5219-—91 Continued Table 7 Protective tube diameter Four types of A-Φ8, Φ10mm, Φ12mm and 15mm. This standard is proposed and managed by the National Technical Committee for Industrial Process Measurement and Control Standardization. This standard is managed by the Shanghai Institute of Industrial Automation Instruments of the Ministry of Machinery and Electronics Industry. This standard was drafted by Shanghai Automation Instrument Factory No. 3. The main drafters of this standard are Han Xiaobai, Huang Baokui, He Guoliang and He Shihao. 2 Nominal pressure 222.5 Atmospheric pressure Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.