title>Packaging—Basic tests for transport packages—Part 10:Sinusoidal vibration test method using at variable vibration frequency - GB/T 4857.10-2005 - Chinese standardNet - bzxz.net
Home > GB > Packaging—Basic tests for transport packages—Part 10:Sinusoidal vibration test method using at variable vibration frequency
Packaging—Basic tests for transport packages—Part 10:Sinusoidal vibration test method using at variable vibration frequency
Basic Information
Standard ID:
GB/T 4857.10-2005
Standard Name:Packaging—Basic tests for transport packages—Part 10:Sinusoidal vibration test method using at variable vibration frequency
drafter:Huang Xue, Tang Shutian, Zhou Shu, Li Ping, Zhou Jiayan, Ba Peng, Wang Wei
Drafting unit:China Machinery Productivity Promotion Center, Suzhou Testing Instrument Factory, Shenyang Ligong University, Beijing Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, National Packaging Product Quality Supervision and In
Focal point unit:National Packaging Standardization Technical Committee
Publishing department:General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Standardization Administration of China
This part of GB/T 4857 specifies the main performance requirements, test procedures and test report contents of the test equipment used in the sine variable frequency vibration test for transport packages and single goods. This part is applicable to the assessment of the strength of transport packages and single goods under sine variable frequency vibration or resonance and the protection of the packaging to the contents. It can be used as a single test or as part of a series of tests. GB/T 4857.10-2005 Packaging Basic tests for transport packages Part 10: Sine variable frequency vibration test method GB/T4857.10-2005 Standard download decompression password: www.bzxz.net
This part of GB/T 4857 specifies the main performance requirements, test procedures and test report contents of the test equipment used in the sine variable frequency vibration test for transport packages and single goods.
This part is applicable to the assessment of the strength of transport packages and single goods under sine variable frequency vibration or resonance and the protection of the packaging to the contents. It can be used as a single test or as part of a series of tests.
Some standard content:
[CS55.020 National Standard of the People's Republic of China GH/T4857.10-—2005 Alternative GB/T13s7.10-1S92 Basic tests for transport packages Part 10: Sinusoidal variable frequency vibration test method Packagin-Basiclests for transport packages-Parl 10: Sinusoidal vibration test method frcqcncy(1S08318.2000,M()) 2005-05-25Released General Logistics Department of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of China 2005-11-01Implementation The 18 other tests on benzene in transport loading and unloading are divided into 3 parts:Part 1: Test methods for various parts of the loading and unloading:Part 2: Degree of protection and treatment:Part 3: Test methods for stacking of loading and unloading structures:Part 4: Test methods for strength:Part 5: New test methods for jumping:Part 6: Test methods for delivery Part 7: Vibration test methods:Part 8: Hexagonal test methods; Part 9: Quality test and method! 10 minutes, sinusoidal vibration test method: Part 1, horizontal impact test method; : Part 12, no transportation! Part 13, air pressure test method Part 14, low shear method Part 15, controlled horizontal impact test method! Part 16: Stacking method for small-scale inspection machines: Part 17 Preparation of performance test sheet for large steel stocks: Part 18, Preparation of quantitative data for performance test! Part 19 General requirements for circulation integrity inspection: Part 20: Magnetic test method: Part 21: Each test cold left method Www.bzxZ.net Part 22: General unit cargo transfer test method; Part 25: Extended machine vibration test method, GB/T 4857.10—200 This part of GB46.10, this part adopts the international standard 18518:2200 complete packaging, full positive strong frequency conversion alarm or emergency, for (/485, 10—12 packaging: transport to the package of special package unit cargo variable frequency conversion test method compared with 15818 standard, the following differences: - According to Chinese pregnancy habits, some traceability formats have been modified; reduce the relevant explanatory samples, Due to the definition of relevant technical spectrum in the packaging technical standard, the provisions of "test resistance or temperature conditions" with American definition were cancelled, and the requirements were widened compared with the standard. The appendix A (for other users to determine the reporting time) was added. According to the trend of GB 4857 standard and the actual use conditions, the relevant contents of the test report were reviewed. Compared with GB 4857, 10-1992, the main changes are as follows: the original "only for transport packaging" was used in the specification. The modification of the fire applicable to the thirteen transport packaging units will be higher than the original requirements on the table surface! The standard modification is effective for the corner doctor to accept the chemical requirements of the standard to add the current provisions of the time-pass test positioner: The actual requirements for or such as speed are eliminated, GB/T4857.10—2005 The time-sensitive A of this part is a judgment appendix. The actual mouth of the part is pure, and the time period is G/4857.101992 This part will be published in China. The technical committee of standardization proposed the opening of the unified. The main contributors of this part are: China Machinery Productivity Promotion Center, Banzhou Testing Instrument Factory, Fashen University of Science and Technology, Beijing Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, and National Quality Supervision and Inspection Center for Table Products (Nanjing). The main drafters of this part are: Huang Wan, Ce Shushan, Zhou Haili Ban, Zhou Ruzhang, Printing, Sub-authority, 7 1 Scope Basic test for packaging and transport packages Part 10: Normal frequency vibration test method GB/T 4857.10—2005 The second part of B/T4R57 specifies the main performance requirements, test procedures and test reports of the test equipment used for the normal frequency conversion test of transport packages and unit cargo. This part is applicable to evaluate the protection of the contents of transport packages and unit cargo under normal frequency conversion or other conditions. It can be used as a single test or as a group or part of a series of tests. 2 Normative references The following clauses are used as clauses of this part through the reference of (13/T4857 part ... The referenced document and its subsequent entirety (excluding the contents of the instructions) or its version are not applicable to this part. However, the parties to an agreement on this part are encouraged to study whether the latest edition can be used as soon as possible. For all referenced documents without an import date, the latest edition shall apply to this part GB/T 4857.1 Method of marking various parts of package parts CB/T 4857.2 Packaging Temperature and humidity treatment of package parts GB/T 4857.3 Test method for static load stacking Transport package parts /T 4857.1? General principles of the test of packaging and transport package and component quality H4%5Y18 transport according to the outline of the packaging component quality test 3 Test principle The test sample is vibrated. Within a specified time, the test sample is subjected to a predetermined vibration at a frequency between 122 and 1) Hz. If necessary, a certain load can be added to the test sample to simulate the environment of the transport package being subjected to a static vibration at the bottom of the stack. 4 Test equipment 4.1 Vibration table The vibration table should have sufficient size, strength, rigidity and or capacity: the structure should be able to ensure that the vibration table surface remains horizontal during vibration, and its resonance rate should be reduced to a maximum test frequency. The vibration table should be level and the maximum angle change between the seat and the required level is 03°. The vibration table can be equipped with various types of 2) Low frame to prevent the test sample from falling to both ends and sides during vertical test; 3) High frame to prevent the test sample from shifting when driven by the load on the test product; 4) Used to fix the packaged goods during transportation. In addition, the vibration table must comply with the requirements specified in 5.5.3. 4.2 Receivers The test equipment shall also include accelerometers, pulse width regulators and data display or storage devices to control the speed on the surface of the test product. The test system shall be designed to prevent the product from falling out of the packaging. The receiver can be equipped to control the amplitude and frequency of the vibration of the product on the packaging. 5 Test procedure 5.1 Preparation of test samples Prepare test samples according to GB/T 7.7: 1 GB/T 4857.10—2005 5.2 Numbering of test sample parts According to the provisions of (B4357.1, the test sample parts shall be numbered. 5.3 Pretreatment of test samples According to the provisions of GBT4357.1, the test samples shall be pretreated with humidity under certain conditions. 5.4 Temperature and humidity conditions during testing The test shall be carried out under the same temperature and humidity conditions as the pretreatment. If the treatment conditions are different, they must be included in the test selection. Start the test within 5 minutes of leaving the independent station. 5.5 Reading steps 5.5.1 Record the humidity of the test site. 5.5.2 Place the test sample on the test bench in a state of emergency. The position of the test sample's center of gravity should be as close as possible to the actual geometric center of the test bench. If the test sample is not fixed on the surface, an extension can be used. If necessary, the test sample can be added with a pre-cut. The degree of addition is as specified in (/T1857.3, 5. 5.3 Method A 5.5.3.1 Make the measuring instrument move at a constant acceleration and a sweeping frequency of 1/3-1/2 minutes. Perform the sweeping test between 3 Hz and 1/2 Hz. Repeat the sweeping test. 5.5.3.2 When measuring the resistance, place the measuring instrument as close as possible to the probe table of the package. However, protective measures should be taken to prevent the measuring instrument from contacting the package. 5.5.3.3 When there is residual water, the component can cause the average drop of 20% of the vertical component. 5.5.4 Method 5.5.4.1 Perform the test in accordance with the procedure of Method A, using an appropriate low speed value (typically within the range of 0.2-3) and a micro-vibration gate number, and a test frequency value greater than or equal to 5.5.4.2 Perform the test within the range of 1% of the quasi-resonant frequency, and perform the test within 1% of the second and third resonant frequencies. The duration of the test shall be shortened to 5.5.5 After the test, inspect the packaging and contents for damage in accordance with relevant regulations and make an analysis of the test conclusions. 6 Test report The test report shall include: a) Description of the test system: Name, form, model and value of contents; the intended contents to be used shall be described in detail; Detailed description of the name and size of the packaging container, specifications of the construction materials, properties, strength, balance, preparation method, discussion, bundling concept and other protective measures; Mass of the test product and contents: in kilograms; Whether to add a larger load; describe the mass of the added load (in kilograms); how long the test sample can withstand the load; Test method: product placement method; The time and space required for the case to be handled promptly; Test site range and relative flow: ) Report the frequency and frequency when 1 is added, if the method B is used, prove the frequency and the first and second original rates; Test results: determine the details of the planned case and how to explain the results; m) Test result analysis ) Explanation of the test method used and the benefits of this part:) Test period, completion personnel signature, test unit agreement, 2 Appendix A (Informative Appendix) Determination of vibration time GB/T 4857,10-2005 Report duration time is generally strict product standard according to the specific living environment conditions: end timing is not recommended: a) Sweep frequency test t3Hz—130Hz—3Hz. Repeat twice, common excavation test, stay on the common frequency for 15mi b) Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.