title>JB/T 10017-1999 Caliper gauge - JB/T 10017-1999 - Chinese standardNet - bzxz.net
Home > JB > JB/T 10017-1999 Caliper gauge
JB/T 10017-1999 Caliper gauge

Basic Information

Standard ID: JB/T 10017-1999

Standard Name: Caliper gauge

Chinese Name: 带表卡规

Standard category:Machinery Industry Standard (JB)

state:in force

Date of Release1999-05-20

Date of Implementation:2000-01-01

standard classification number

Standard ICS number:Mechanical Manufacturing>>Machine Tool Devices>>25.060.20 Indexing and Tool/Workpiece Holding Devices

Standard Classification Number:Machinery>>Process Equipment>>J42 Measuring Tools and Measuring Instruments

associated standards

alternative situation:ZB J42015-1987

Publication information

other information

Focal point unit:National Technical Committee for Standardization of Measuring Tools and Instruments

Publishing department:National Technical Committee for Standardization of Measuring Tools and Instruments

Introduction to standards:

JB/T 10017-1999 This standard is a revision of ZB J42 015-88 "Caliper Gauge with Meter". During the revision, only editorial changes were made according to relevant regulations, and the technical content was not changed. This standard specifies the type, basic parameters and dimensions, technical requirements, marking and packaging of caliper gauges with meter. This standard is applicable to internal caliper gauges with a graduation value of 0.01mm and a measuring range of 10 to 100mm and external caliper gauges with graduation values ​​of 0.01mm, 0.02mm, 0.05mm, 0.10mm and a measuring range of up to 100mm. This standard was first issued on August 13, 1987. JB/T 10017-1999 Caliper Gauge with Meter JB/T10017-1999 Standard download decompression password: www.bzxz.net

Some standard content:

ICS 25.060.20
Machinery Industry Standard of the People's Republic of China
JB/F1H171999
Dial snap gauge
Issued on 1999-05-20
National Bureau of Machinery IndustryWww.bzxZ.net
2000-01-01 Implementation
JB/T10017-1999
This standard is formulated on the basis of 7BJ42015-87 "Dial snap gauge". This standard is consistent with the technical content of 7.B142015-87, and has only been revised in accordance with relevant regulations. This standard replaces Z0J4215-B7 from the date of implementation. Appendix A of this standard is the appendix of the standard.
This standard is proposed and managed by the National Basic Instrument Standardization Technical Committee. Drafting unit: Guilin Fengyi Yingqi Factory. Participating drafting unit of this standard: Weihai Measuring Tool Factory, main drafters of this standard: Lin Guanhua, Yang Shengwen. This standard was first issued in 1987.
Mechanical Industry Standard of the People's Republic of China
Caliper gauge with table
Diuladnp gange
JB/T00F7—1999
Generation Group 4201587
This standard specifies the type, required number and size, technical requirements, marking and packaging of caliper gauge with table. This standard is applicable to internal caliper gauges with a graduation of 0.01mm and a measuring range of 10~100mm and graduation values ​​of 0.01mm, 0.2mm, 0.05taml, 0.10mm, and a measuring range of 100mm. Definitions
This standard adopts the following definitions.
z.1 Caliper gauge with dial
Uses a rotary transmission mechanism to convert the movement of the claw plate into the movement of the dial indicator rod, and the dial indicator is used to measure the measurement.
1.2 Measurement accuracy
The measuring plate head of the caliper gauge with dial can measure the accuracy of the measured part (hole). 2.3 Indication error
The difference between the indication of the dial indicator on the caliper gauge and the distance between the two measuring surfaces. 3 Type, basic parameters and size
3. The types of caliper gauge with inner gauge and caliper gauge with outer gauge are shown in Figures 1 and 2 (Figures are for illustration only and are not for showing detailed structure).
National Bureau of Statistics
Figure 1 Caliper gauge with inner gauge
Approved by National Bureau of Statistics on May 20, 1999 and implemented on January 1, 2000
JB/T1007-1999
Quantity source
Figure 2 Caliper gauge with outer gauge
3.2 The graduation value, measuring range and measuring degree of caliper gauge with inner gauge and caliper gauge with outer gauge are shown in Table 1. Name
Caliper gauge with inner gauge
Section Caliper gauge with outer gauge
4 Technical requirements
Classification
0-201 20-10 40-60;618: 8-1000~26h
4.1 The dial gauge shall not have any external depressions that may affect its performance. mm
Maximum depth
.59: 80: 100
4.2 The dial gauge 1. The installation of the dial gauge shall be firm and reliable, and the movement of the movable measuring claws shall be smooth and flexible without any jamming. 4.3 When the distance between the two measuring discs of the dial gauge is equal to the lower limit of measurement, the pointer of the dial indicator shall point to the upper side of the measuring axis, and the setting difference shall not exceed +5
4. The hardness of the measuring surface of the dial gauge shall not be less than 766JIV (62HRC). When the auxiliary disc head is made of stainless steel, the hardness of the measuring disc surface shall not be less than 528HV (=52.5IJRC).
4.5 The surface hardness R of the measuring surface of the lower gauge with a dial is 0. 1m2
4.6 The measuring range of the dial gauge should be 2~4N
JB/T10017-1999
4.7 The indication error and indication variability of the dial gauge should not exceed the specifications in Table 2. Table 2
In-dash gauge:
Good dial gauge
In-dash gauge
5 Marking and packaging
5.1 The dial gauge should be marked with the manufacturer's name or trademark;
6) Graduation value:
) Range:
) Product serial number.
5.2 The packaging box of the caliper gauge should be marked with the manufacturer's name or the trademark of the company; b) product name (caliper gauge with internal gauge or caliper gauge with external gauge, measurement error, position change, accuracy value, etc. 5.3 The caliper gauge with internal gauge should be rust-proofed and properly installed before packaging. The packaging should not be lost or damaged during transportation. 5.4 The caliper gauge with internal gauge that has been verified to meet the requirements of this standard should be accompanied by a product certificate, which should have the standard number, product serial number and publication date of this standard. JB/T10 0171999
Appendix A
(Appendix to the Standard)
Test Method for caliper gauge
This appendix is ​​about the test method for factory inspection of caliper gauge. A1 Indication Error
The indication error range of caliper gauge is measured by using the inner scale composed of outer diameter scale or 3-degree scale and disc block. When the two measuring surfaces of the caliper gauge are connected with the measuring surface of the micrometer or disc block clamp, the difference between the indication value on the dial indicator and the indication value of the outer diameter scale or the inner scale composed of the disc block is the indication error of the caliper gauge. This test should be carried out at least on four positions evenly distributed within the measuring range. The error test of the indication of the external caliper gauge is to place the level 3 piece between the two measuring surfaces of the external caliper gauge. The difference between the dial indicator indication and the monitoring scale is the error of the indication of the external caliper gauge. This test should be carried out at least on four positions evenly distributed within the measuring range. A2 Indication variability
The inspection of the indication variability is to perform repeated measurements on the measured value through numerical variation or measurement. The difference between the daily indication and the minimum indication is the indication variability of the caliper gauge. A3 Measuring force
The force of the caliper gauge is to use a force less than 0.1N to measure the force in the measuring range.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.