This standard specifies the type and basic parameters of hot coils. This standard applies to air conditioning, ventilation, and heating coils whose medium is hot water or steam and whose maximum working pressure does not exceed 1.3 MPa. This standard does not apply to coils using electric heating, thermal oil and other heating media. JB/T 6414-1992 Thermal coil type and basic parameters JB/T6414-1992 Standard download and decompression password: www.bzxz.net
Some standard content:
Machinery Industry Standard of the People's Republic of China Hot Coil Subject Content and Scope of Application Type and Basic Parameters This standard specifies the type and basic parameters of the hot coil . JB/T 6414—92 This standard is applicable to air conditioning, ventilation, and heating coils whose medium is hot water or steam and the maximum working pressure does not exceed 1.3MPa. This standard does not apply to coils using electric heating, thermal oil and other heating media. 2 Reference standards JB4302 Heating and cooling ventilation equipment model compilation method 3 types 3.1 Medium circulation mode 3.1.1 Straight-through type (Figure 1) All heat exchange tubes The flow of media is consistent and passes through at once. Import Port Figure 1 3.1.2 Single and multi-pass formula (Figure 2) The heat medium makes one or more round trips in the heat exchange tube passage flow. Import one port 3.2 structural type 3.2.1 rectangular (Figure 3) Figure 2 Ministry of Mechanical and Electronics Industry of the People's Republic of China 1992- 07-20 Approved for export Implemented by 1993-01-01 731 3.2.2 round (Picture 4) 3.3 model| |tt||JB/T 6414—92 Figure 3 Export Figure 4 The hot coil model preparation method is in accordance with the provisions of JB4302. 4 Basic number 4.1 The rated working conditions are specified in Table 1. Table 1 number parameter high temperature air inlet state dry bulb temperature water supply state water inlet Temperature Water velocity Steam pressure (gauge pressure) Windward flow velocity 4.2 Structural parameters are as specified in Table 2 732||tt| |C 95 m/s MPa m/s 4 water low temperature|| tt||20 60 2.5 $ import one export steam 0.1||tt ||4 Laminated tube Rolled tube item item laminated tube steel-steel||tt ||Aluminum-aluminum Steel-aluminum Aluminum Copper Steel-aluminum composite Copper-aluminum composite Copper- Aluminum sleeve tube Nominal diameter of heat medium inlet and outlet pipe joint No. of tube rows Material Steel Aluminum Copper Steel Copper JB/T 641492 Table 2 Tube Sub Outer diameter||tt ||a 9.0~30 10~16 18~25 16~50 1734 12~26| |tt||16~25 9~~16 Wall thickness 2~3 0.75~1 2-3||tt ||24 1~2 2~2.5 1~~1.5 0.351 Note: D material is a single metal (aluminum, copper ) The wall thickness of the rolled sheet tube is the size after rolling. ②The rib tube bundles are arranged in regular or staggered rows along the air flow direction. Additional notes: This standard is proposed and administered by the Hefei General Machinery Research Institute of the Ministry of Mechanical and Electronics Industry. This standard is drafted by Tianjin Heater Factory. The main drafter of this standard: Zhang Zhicheng. Material steel lanthanum lead aluminum steel aluminum aluminum copper| |tt||Aluminum 15~80 1~10 rib sheet thickness 0.3~0.5 0. 2 0. 3~~0. 5 0. 3~~0. 6 0.45~0.6 0.3~0. 65 0.15 ~0.3 piece piece height h 10~16 10 11~16 mm| |tt||Film pitch E 315bZxz.net 3.2 19.515.82.32.8 1116 5~10|| tt||8~10 9~16 1.8-5 3.2~4.2 2.3~~5 1.8~5||tt ||733 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.