title>JB/T 6663.1-1993 Types and basic parameters of light and small single-stage centrifugal pumps - JB/T 6663.1-1993 - Chinese standardNet - bzxz.net
Home > JB > JB/T 6663.1-1993 Types and basic parameters of light and small single-stage centrifugal pumps
JB/T 6663.1-1993 Types and basic parameters of light and small single-stage centrifugal pumps

Basic Information

Standard ID: JB/T 6663.1-1993

Standard Name: Types and basic parameters of light and small single-stage centrifugal pumps

Chinese Name: 轻小型单级离心泵 型式与基本参数

Standard category:Machinery Industry Standard (JB)

state:Abolished

Date of Release1993-06-04

Date of Implementation:1994-01-01

Date of Expiration:2008-03-01

standard classification number

Standard Classification Number:Agriculture & Forestry>>Agricultural & Forestry Machinery & Equipment>>B91 Agricultural Machinery

associated standards

alternative situation:Replaced by JB/T 6663-2007

Publication information

other information

Focal point unit:Chinese Academy of Agricultural Mechanization Sciences

Publishing department:Chinese Academy of Agricultural Mechanization Sciences

Introduction to standards:

This standard specifies the type, model and basic parameters of light and small single-stage centrifugal pumps. This standard applies to light and small single-stage centrifugal pumps with a flow rate of 8~400m3/h, a head of 6~90m, and a working pressure of 0.6~1.6MPa. JB/T 6663.1-1993 Types and basic parameters of light and small single-stage centrifugal pumps JB/T6663.1-1993 Standard download decompression password: www.bzxz.net

Some standard content:

Mechanical Industry Standard of the People's Republic of China
JB/T6663.1~6663.2-93
Light and small single-stage centrifugal pumps
Published on June 4, 1993
Ministry of Machinery Industry of the People's Republic of China
Implementation on January 1, 1994
JB/T6663.1-93
Light and small single-stage centrifugal pumpsbzxZ.net
JB/T.6663.2-93
Light and small single-stage centrifugal pumps
Types and basic parameters
Technical conditions
Mechanical Industry Standard of the People's Republic of China
Light and small single-stage centrifugal pumps
Types and basic parameters
1 Subject content and scope of application
This standard specifies the types, models and basic parameters of light and small single-stage centrifugal pumps. JB/T 6663.193
This standard applies to light and small single-stage centrifugal pumps (hereinafter referred to as pumps) with a flow rate of 8 to 400 m/h, a head of 6 to 90 m, and a working pressure of 0.6 to 1.6 MPa.
2 Reference standards
GB3216
GB4216
GB/T13006
JB/T·6663.2
3 Types
Test methods for centrifugal pumps, mixed flow pumps, axial flow pumps and vortex pumps Size of flange for gray cast iron pipes
Centrifugal pumps, mixed flow pumps and axial flow pumps NPSH Technical conditions for light and small single-stage centrifugal pumps
3.1 The structural type of the pump is axial suction, single-stage, horizontal, with the water outlet vertically upward and passing through the axis, the pump foot and the pump body are cast as one piece, and the bearing body does not have an intermediate bracket.
3.2 The connection dimensions of the pump inlet and outlet flanges shall comply with the provisions of GB4216. A square flange may be used for flanges with four connecting bolts. For pumps with an inlet nominal diameter less than or equal to 80 mm, the inlet may be threaded and the outlet may be connected with a 4-threaded square flange. 3.3 The power transmission mode between the pump and the diesel engine or motor is divided into direct drive (including coaxial) and belt drive. 3.4 Pump shaft rotation direction: For pumps with direct drive, the rotation direction is counterclockwise from the pump inlet; for pumps with belt drive, the rotation direction is clockwise from the pump inlet.
4 Model
4.1 Model indication method
The pump model is indicated by uppercase Latin letters and Arabic numerals, and the composition and meaning are as follows: IQ
Rated (standard) power of the power machine (keep one decimal place when matching diesel engine), kW (basic model can be omitted)
Transmission mode: D represents electric motor direct drive (basic model can be omitted), B represents belt drive (basic model can be omitted), C represents diesel engine direct drive Impeller nominal diameter, mm
Pump inlet nominal diameter, mm
Light and small single-stage centrifugal pump
4.2 Marking example
A basic light and small single-stage centrifugal pump with an inlet nominal diameter of 65mm, an impeller nominal diameter of 160mm, an electric motor and a direct drive mode is marked as: IQ65-160. The import nominal diameter is 80mm, the impeller nominal diameter is 125mm, and it is equipped with a diesel engine. The transmission mode is a basic type of light and small machinery industry approved by the Ministry of Industry on June 4, 1993 and implemented on January 1, 1994. The single-stage centrifugal pump is marked as IQ80-125C. The import nominal diameter of JB/T6663.193 is 50mm, the impeller nominal diameter is 250mm, and it is equipped with a diesel engine with a rated power of 5.88kW. The transmission mode is a light and small single-stage centrifugal pump with a direct drive. The mark is IQ50-250C5.9. The import nominal diameter is 65mm, the impeller nominal diameter is 180mm, and it is equipped with a diesel engine with a rated power of 4.41kW. The transmission mode is a belt drive light and small single-stage centrifugal pump, which is marked as IQ65-180B4.4. Basic parameters
5.1 The basic parameters of the basic type ticket of belt drive and motor direct drive shall comply with the provisions of Table 1, and the series type spectrum is shown in Figure 1. The basic parameters of the variant ticket formed by changing the impeller outer diameter or speed shall comply with the provisions of Appendix A (Supplement). 5.2 The basic parameters of the basic type pump of diesel engine direct drive shall comply with the provisions of Table 2, and the series type spectrum is shown in Figure 2. The basic parameters of the variant pump formed by changing the impeller outer diameter or speed shall comply with the provisions of Appendix B (Supplement). 5.3 The deviation of the basic parameters shall comply with the provisions of Class C in GB3216. Other single-stage centrifugal pumps other than those specified in this standard shall comply with the following provisions: 5.4
The specified efficiency shall not be lower than the provisions of curve A of Figure C1 (or column A of Table C1) and curve C2 (or table C2) in Appendix C (supplement). The efficiency of the modified ticket formed by changing the outer diameter or speed of the impeller shall comply with the provisions of curve B of Figure C1 (or column B of Table C1) and Figure C2 (or table C2) in Appendix C; b.
The specified critical NPSH of the pump shall not be greater than that specified in GB/T13006: The power reserve factor of the pump's supporting power machine is 1.1~1.4; other technical requirements shall comply with the provisions of JB/T6663.2. Table 1 | | tt | t||IQ65-160
1Q65-200
IQ65-250
IQ65-90
IQ65-110
I Q65-140
IQ65-180
IQ80-80
IQ80-100
Nominal diameter
Export diameter
Nominal diameter
Shaft power
Critical steam
Position margin
Impeller diameter
Nominal diameter
Q80-125
Q80-160
IQ80-200
1Q80-250
1Q100-90
IQ10 0-110 | | tt | | IQ100-140 | 140
IQ150-185
IQ150-200
IQ150-125
IQ150-250
IQ150-1 60
IQ150-315
IQ125-200
IQ200-200
IQ200-250
IQ200-315
IQ50-180C
IQ50-220C
IQ50-160C
IQ50-200C
IQ50-250C
Imported male
Nominal diameter
Imported male
Nominal diameter
JB/T 6663.193
Continued Table 1
Export male
Nominal diameter
Export male
Nominal diameter
Shaft power
Shaft power
Critical steam
Pipping margin
Critical steam
Pipping margin
Impeller male
Nominal diameter
Impeller male
Nominal diameter||t t | |IQ65-140C
IQ65 -180C | |tt | 140C
IQ100-25 0C
IQ100-100C
IQ100-125C
IQ100-160C
IQ150-140C
IQ150-180C
IQ150-160C
IQ150-125C
Imported metric
nominal diameter
JB/T 6663.1 93
Continued Table 2
Export male
Nominal diameter
Shaft power
Critical steam
Positive erosion margin
Impeller male
Nominal diameter
TQs0-250
1Q50-200
TQ50-150
Q50-125
1950-10g
Q65-250|| tt | 60708090100
300400500600
Q m*/h
Basic pump series spectrum with belt drive and electric motor direct drive 20
506070809010
Basic pump series spectrum with diesel engine direct drive 200
IQ50-100D0.75
IQ50-100D1.1
IQ50-125D1.1
IQ50-125D1.5
IQ50-160D1.5
IQ50-160D2.2
IQ50-160D3||tt ||IQ50-160B2.2
IQ50-200D3
IQ50-200D4
IQ50-200D5.5
IQ50-200B2.2
IQ50-200B2.9
IQ50-200B3.7||tt ||IQ50-250D7.5
IQ50-250D11
IQ50-250B5.2
IQ50-250B5.9
IQ50-250B 6.6
IQ50-250B8.8
IQ65-80D0.75
IQ65-80D1.1
IQ65-100D1.1
IQ65-100D1.5
IQ65-125D1.5
IQ65-125D2.2
IQ65-125D3
IQ65-125B2.2
JB/T6663.1-93
Appendix A
Belt drive and motor Basic parameters of coupled transmission variable pump (supplementary parts)
Export metric
Nominal diameter
Matching power machine
Rated (standard)
Power kw
Critical steam
Potential loss
IQ65-160D3
IQ65-160D4
IQ65-160D5.5
IQ65-160B2.2
IQ65-160B2.9
IQ65-160B3.7
IQ65-160B4. 4
IQ65-200D5.5
IQ65-200D7.5
IQ65-200D7.5A
IQ65-200B4.4
IQ65-200B5.2
IQ65-200B5.9
IQ65-2 00B6.6
IQ65-250D11
IQ65-250D15
IQ65-250B6.6
IQ65-250 B8.8 | |tt | 10D3
IQ65-110B2.2
IQ65-140D3
IQ65-140D4
IQ65-140B2. 9
IQ65-140B3.7
IQ65-140B4.4
IQ65-180D5.5
IQ65-180D7.5
Export Nominal Diameter
JB/T 6663.193
Continued Table A1
Matching power machine
Rated (standard)
Power kW
Critical steam
Positive displacement
IQ65-180B4.4
IQ65-180B5.2
IQ65-180B5.9
IQ65-180B6.6
IQ80-80D1.1
IQ80-80D2.2
IQ80-100D2.2
IQ80-100D3
IQ80-100D4|| tt | |tt||IQ80-125B4.4
IQ80-160D5.5
Q80-160D7.5
IQ80-160B5.2
IQ80-160B5.9
IQ80-160R6. 6
IQ80-200D7.5
IQ80-200D11
IQ80-200B6.6
1Q80-200B8.8
IQ80-200B11.0
IQ80-250D15
IQ80-25 0D1 8.5
IQ80-250D22
IQ80-250B11.0
IQ80-250R14.7
IQ80-250B17.7
IQ80-250B22.1
Export
Nominal diameter
JB/T 6663.193
Continued Table A1
Matching power machine
Rated (standard)
Power kW
Critical steam
Position margin
1Q100-90D2.2
IQ100-90D3
1Q100-110D+
IQ100-110D5.5
IQ100-110B2. 9
IQ100-110B3.7||tt ||IQ100-110B4. 4
IQ100-110B5.2
IQ100-140D5. 5
IQ100-140D7.5
IQ100-140D7.5A||tt ||IQ100-140B5.2
IQ100-140B5. 9
IQ100-140B8.1
IQ100-100D3
IQ100-100D4
IQ100-100D5.5
IQ100-100B2. 9||tt ||IQ100-100B3.7
IQ100-100B4.4
IQ100-100B5.2
IQ100-125D5.5
IQ100-125D7.5||tt ||IQ100-125B5.2
IQ100-125B5. 9
IQ100-125B6.6
IQ100-125B8.8
IQ100-160D7.5
1Q100-160D11
IQ100-160D15||tt ||IQ100-160B6.6
IQ100-160B8.8
IQ100-160B11.0
IQ100-160B14.7
Export metric
Diameter
JB/T 6663.193
Continued Table A1
Matching power machine
Rated (standard)
Power kw
Critical steam
Potential loss margin
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.