This standard specifies the types and basic parameters of air outlets in ventilation and air conditioning systems. This standard applies to all types of air outlets and air inlets in ventilation and air conditioning systems. JB/T 6416-1992 Air outlet types and basic parameters JB/T6416-1992 Standard download decompression password: www.bzxz.net
Some standard content:
Mechanical Industry Standard of the People's Republic of China JB/T6416-1992 Type and basic parameters Published on July 20, 1992 Implementation by the Ministry of Machinery and Electronics Industry of the People's Republic of China on January 1, 1993 Mechanical Industry Standard of the People's Republic of China Subject content and scope of application Type and basic parameters This standard specifies the type and basic parameters of the air outlets of ventilation and air conditioning systems. This standard applies to all types of air outlets for air inlet and outlet in ventilation and air conditioning systems. Type The air outlet type code is specified in Table 1. Name of air outlet Single-layer movable shutter air outlet Double-layer movable shutter air outlet Single-layer fixed shutter air outlet Double-layer fixed shutter air outlet Ground shutter air outlet Self-hanging shutter air outlet Light shutter air outlet Square diffuser Rectangular diffuser Circular diffuser Disc diffuser Model compilation shall be in accordance with the following provisions Model example: FBHD-250×500-L Type code Material code: See Table 5 Rectangular nozzle Circular nozzle Spherical nozzle Moving blade slit air outlet Fixed blade slit air outlet Swirl air outlet Orifice air outlet Mesh plate air outlet Lamp air outlet Orifice air outlet Basic parameters: width × length or diameter (see Table 2, 3, 4) Type code: See Table 1 Air outlet code Length 500mm. Indicates aluminum single-layer movable shutter air outlet, width 250mm, FSY-200-S Indicates plastic round diffuser, diameter 200mm. The Ministry of Machinery and Electronics Industry approved JB/T6416-1992 on July 20, 1992. Model code. Implementation on January 1, 1993. Basic parameters. JB/T6416-1992. Basic parameters of air outlet. Neck size (referring to the interface size with the air duct) 3.1. The diameter of the circular air outlet shall be as specified in Table 2. The first series shall be adopted first. square, rectangular air outlet basic parameters 120×120 120×160 120×200 120×250 120×320 120×400 120×500 120×63 0 120×800 120×1000 120×1250 120×1600 120×2 000 160×160 160×200 160×250 160×320 means. (width×length) is as specified in Table 3. 160×400 160×500 160×630 160×800wwW.bzxz.Net 160×1000 160×1250 160×1600 160×2.000 200×200 200×250 200×320 200×400 200×500 200×630 200×800 200×1000 200×1250 Slit-shaped air outlet, 200×1600 200×2000 250×250 250×320 250×400 250×500 250×630 250×800 250×1000 250 × 1250 | | tt | | 250 × 1600 | | tt | In addition to circular air outlets, the basic parameters of rectangular diffusers can also be specified in Table 4 according to the equal interval number 50, square, and movable blade slit air outlets. 320 × 1000 | | tt | | 320 × 1250 | | tt | |400 × 1250 | | tt | | 400 × 1600 | | tt | | 400 × 2000 | | tt | | 500 × 500 | | tt | mm×mm 500×1600 500×2000 630×630 630×800 630×1000 630×1250 630×1600 630×2000||tt ||800×800||tt| |800×1000 800×1250 800×1600 800×2000 1000×1000 1000×1250 1000×1600 1000×2000 Number of blade groups/piece Material and code are as specified in Table 5. Material type Additional instructions: JB/T6416-1992 1500,2000 500, This standard is proposed and managed by the Hefei General Machinery Research Institute of the Ministry of Machinery and Electronics Industry. This standard is drafted by the Beijing Qingyun Instrument Factory of the Ministry of Aeronautics and Astronautics. Yao Zihua, Ma Jiafu. The drafters of this standard are Wang Shuzhen, GRP Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.