Standard ICS number:Metrology and measurement, physical phenomena>>Thermodynamics and temperature measurement>>17.200.20 Temperature measurement instruments
Standard Classification Number:Instruments and meters>>Industrial automation instruments and control devices>>N11 temperature and pressure instrument
JB/T 9263.1-1999 Internal Standard Industrial Glass Thermometer Type and JB/T9263.1-1999 Standard Download Decompression Password: www.bzxz.net
Some standard content:
ICS 17.200.20 Machinery Industry Standard of the People's Republic of China B/T9263.1—1999 Inner-scale industrial glass thermometers Types and basic dimensions The types and fundamental stzes otenclosed-scale mdustrial thermormeters1999-08-06Promulgated National Bureau of Machinery Industry Implementation on 2000-01-01 JB T926S.11999 This special standard is a certification of 2B271—84 inner-scale industrial glass thermometer types and basic dimensions>. This standard number ZBY271-8 is different in the three major technical contents, and only the original standard has been revised. From the implementation of this standard, it replaces ZRY27I-24. The standard is proposed and managed by the Regional Industrial Process Quality and Control Standardization Technical Committee. The three major drafting units of this standard are: Beijing Glass Research Institute. The main drafters of this standard are: Xie Zhizhu, Shang Zhangda. The types and basic sizes of internal-scale industrial glass thermometers are specified in this standard. The specifications and dimensions are as follows: JB/TSS.113SS ± 2B 2-]: 3-]: 5-]: 1. The internal-scale industrial glass thermometers shall comply with the provisions of B/T062[9T. The standard does not include metal protective tubes for internal-scale industrial glass thermometers. This standard is used for internal-scale industrial glass thermometers (hereinafter referred to as internal-scale industrial glass thermometers). 2 Type The temperature setting method is the local setting method of the lower body. 3 Lower body shape The body shape of the display is: straight, Figure 1 b19 triangle 2; c! 135 Angle 3. General dimensions shall conform to the requirements of Table 1 and Figure 3.1 Shanghai Institute of Technology 135 ±71 40 - 10 National Machinery Industry Bureau 1989-08-C6 approved directly 160 products 200-10 230-15 300 - 5so-18 2c -1-ot implementation +0 ± 10 JB/T 9263. 1-1399 639 --5 1250-3 1301 - Method: The upper limit of the torsion F is greater than 300 or the lower limit is -50, and the lower limit error is not less than [0Car, and the maximum is not greater than 00d 4 Measurement range, grid value and indication error limit JB/T9269.1-1999 The measurement range, grid value and indication error limit of the temperature gauge shall comply with the provisions of Table 2. 2 Grid use Example measurement 80 - + 30 50 - + 30 33 + 70 0 - 50 0 ~ 100 0 -200 0~ 400 0~ 500 Water meterbzxZ.net With standard resistance pressure gauge Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.