title>GB/T 14598.9-2002 Electrical relays Part 22-3: Electrical disturbance tests for measuring relays and protection devices Radiated electromagnetic field disturbance tests - GB/T 14598.9-2002 - Chinese standardNet - bzxz.net
Home > GB > GB/T 14598.9-2002 Electrical relays Part 22-3: Electrical disturbance tests for measuring relays and protection devices Radiated electromagnetic field disturbance tests
GB/T 14598.9-2002 Electrical relays Part 22-3: Electrical disturbance tests for measuring relays and protection devices Radiated electromagnetic field disturbance tests

Basic Information

Standard ID: GB/T 14598.9-2002

Standard Name: Electrical relays Part 22-3: Electrical disturbance tests for measuring relays and protection devices Radiated electromagnetic field disturbance tests

Chinese Name: 电气继电器 第22-3部分:量度继电器和保护装置的电气骚扰试验 辐射电磁场骚扰试验

Standard category:National Standard (GB)

state:in force

Date of Release2001-12-31

Date of Implementation:2003-04-01

standard classification number

Standard ICS number:Electrical Engineering>>Electrical Devices>>29.120.70 Relay

Standard Classification Number:Electrical Engineering>>Power Transmission and Transformation Equipment>>K45 Relay Protection and Automatic Devices

associated standards

alternative situation:GB/T 14598.9-1995

Procurement status:IEC 60255-22-3:2000,IDT

Publication information

publishing house:China Standards Press

ISBN:155066.1-19250

Publication date:2004-07-22

other information

Release date:1995-07-24

Review date:2004-10-14

Drafting unit:State Power Corporation Power Automation Research Institute

Focal point unit:National Technical Committee for Standardization of Measuring Relays and Protection Equipment

Publishing department:General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

competent authority:China Electrical Equipment Industry Association

Introduction to standards:

This part of GB/T 14598 is based on GB/T 17626.3 and refers to the applicable parts of this publication to specify the general requirements for radiated electromagnetic field disturbance tests. These tests are used for measuring relays and protection devices used for power system protection, including control, monitoring and process interface equipment used in these systems. The purpose of the test is to prove that the equipment under test (EUT) can operate correctly when it is stimulated and exposed to electromagnetic fields emitted by radiating sources operating in the frequency range of 80 Hz to 1 000 MHz. GB/T 14598.9-2002 Electrical relays Part 22-3: Electrical disturbance tests on measuring relays and protection devices Radiated electromagnetic field disturbance tests GB/T14598.9-2002 Standard download decompression password: www.bzxz.net