title>GB/T 5547-1985 Determination of viscosity of resin finishing agents - GB/T 5547-1985 - Chinese standardNet - bzxz.net
Home > GB > GB/T 5547-1985 Determination of viscosity of resin finishing agents
GB/T 5547-1985 Determination of viscosity of resin finishing agents

Basic Information

Standard ID: GB/T 5547-1985

Standard Name: Determination of viscosity of resin finishing agents

Chinese Name: 树脂整理剂 粘度的测定方法

Standard category:National Standard (GB)

state:Abolished

Date of Release1985-10-29

Date of Implementation:1986-08-01

Date of Expiration:2008-06-01

standard classification number

Standard ICS number:Textile and leather technology >> 59.040 Textile auxiliary materials

Standard Classification Number:Chemicals>>Coatings, Pigments, Dyes>>G55 Basic Standards and General Methods for Dyes

associated standards

alternative situation:Replaced by GB/T 5547-2007

Publication information

other information

Review date:2004-10-14

Drafting unit:Dalian Light Industry Research Institute

Focal point unit:National Dye Standardization Technical Committee

Publishing department:National Bureau of Standards

competent authority:China Petroleum and Chemical Industry Association

Introduction to standards:

This standard is applicable to the determination of absolute viscosity of resin finishing agents. GB/T 5547-1985 Determination of viscosity of resin finishing agents GB/T5547-1985 Standard download decompression password: www.bzxz.net

Some standard content:

National Standard of the People's Republic of China
Determinatlon of the viscosity This standard applies to the determination of absolute viscosity of resin finishing agents. 1 Definition
UDC 678.044.33
GB 5547—85
Viscosity is the internal friction of a fluid, the resistance of a layer of fluid to relative motion with another layer of fluid, expressed in moire. 2 Instruments and EquipmentWww.bzxZ.net
2.1 Rotational viscometer: measurement error is less than ±0.5%. 2.2 Super thermostatic bath: temperature fluctuation range is less than ±0.5℃. 2.3 Thermometer: graduation 0.1℃.
2.4 Container: a container with a diameter of 6 to 7 cm and a height of not less than 11 cm or a container attached to a rotational viscometer. 2.5 Stopwatch: accuracy 0.2 seconds.
3 Determination procedures
3.1 According to the viscosity of the sample, select an appropriate rotor and rotation speed so that the reading is within the range of 20-85% of the dial. 3.2 Immerse the rotor vertically into the center of the sample so that the liquid surface reaches the rotor level mark. 3.3 Keep the sample and rotor in the test container at a constant temperature of 25±0.5℃ and keep the sample temperature uniform. 3.4 Read the indicated value when the rotor rotates for 60±2 seconds. 3.5 Calculate the average value of the results of two parallel tests according to the instrument requirements. Additional notes:
This standard was proposed by the Ministry of Chemical Industry of the People's Republic of China and is under the jurisdiction of the Shenyang Chemical Industry Research Institute of the Ministry of Chemical Industry. This standard was drafted by the Dalian Light Chemical Industry Research Institute. The main drafter of this standard is Jin Liwen.