title>HG/T 2642-1994 Test method for tensile strength of impermeable graphite materials - HG/T 2642-1994 - Chinese standardNet - bzxz.net
Home > HG > HG/T 2642-1994 Test method for tensile strength of impermeable graphite materials
HG/T 2642-1994 Test method for tensile strength of impermeable graphite materials

Basic Information

Standard ID: HG/T 2642-1994

Standard Name: Test method for tensile strength of impermeable graphite materials

Chinese Name: 不透性石墨材料抗拉强度试验方法

Standard category:Chemical industry standards (HG)

state:Abolished

Date of Release1994-10-26

Date of Implementation:1995-03-01

Date of Expiration:2007-03-01

standard classification number

Standard ICS number:Chemical Technology>>71.120 Chemical Equipment

Standard Classification Number:Chemical Industry>>Chemical Machinery and Equipment>>G94 Non-metallic Chemical Machinery and Equipment

associated standards

alternative situation:Replaces HG 5-1329-1980; replaced by HG/T 2642-2006

Publication information

other information

Introduction to standards:

HG/T 2642-1994 Test method for tensile strength of impermeable graphite materials HG/T2642-1994 Standard download decompression password: www.bzxz.net

Some standard content:

Chemical Industry Standard of the People's Republic of China
HG/T2642--94
Test Method for Tensile Strength of Impermeable Graphite Materials 1994-10-26 Issued
Ministry of Chemical Industry of the People's Republic of China
Implementation on 1995-03-01
Chemical Industry Standard of the People's Republic of China
Test Method for Tensile Strength of Impermeable Graphite Materials 1 Subject Content and Scope of Application
HG/T2642-94
This standard specifies the instruments, equipment, specimens, specimen fixtures, test steps and result calculation methods used in the tensile strength test of impermeable graphite materials.
This standard applies to the determination of tensile strength of impermeable graphite materials. 2 Reference standards
GB/T13465.1 General principles for test methods for mechanical properties of impermeable graphite materials HG/T2059 Technical conditions for impermeable graphite tubes and fittings 3 Instruments and equipment
Instruments and equipment should comply with the relevant provisions of GB/T13465.1 4 Test specimens
4.1 Sampling, test specimen processing methods and test specimen quantity shall be carried out in accordance with the relevant provisions of GB/T13465.1. 4.2 Test specimen size and shape
4.2.1 The size and shape of the tensile test specimen of impermeable graphite block are shown in Figure 1. 4.2.2 The size and shape of the tensile test specimen of impermeable graphite tube are shown in Figure 2. The size and shape of the tensile test specimen of adhesive castings are shown in Figure 3. 4.2.3
Wind and rain protection facilities should be set up for open-air construction.
There should be no defects on the surface of the effective fracture site of the test specimen that may affect the test results. R93
Approved by the Ministry of Chemical Industry of the People's Republic of China on October 26, 1994 R151
Implemented on March 1, 1995
5 Test fixture
HG/T2642-94
5.1 Impermeable graphite block tensile specimen fixture See Appendix A.5.2 Impermeable graphite tube tensile specimen fixture See Appendix B.5.3 Adhesive casting tensile specimen fixture See Appendix C.6 Test steps
6.1 Number and mark the qualified specimens. The effective fracture position is clear, and the cross-sectional dimensions of the effective fracture position of the sample are measured with a vernier caliper. 6.1.1 Measurement of impermeable graphite block sample: Measure three places along the axial direction of the sample, and measure the mutually perpendicular diameters once at each place, and take the arithmetic mean of the six data obtained.
6.1.2 Measurement of impermeable graphite tube sample: Measure three places along the axial direction of the outer diameter of the sample, and measure the mutually perpendicular diameters once at each place, and measure the inner diameter at the ends of the sample, and measure the mutually perpendicular diameters once at each place, and take the arithmetic mean of the data obtained. 6.1.3 Measurement of adhesive casting sample: Measure three times at the width and thickness of the minimum cross-section of the effective fracture position of the sample, and take the arithmetic mean of the data obtained.
6.2 Place the sample in the fixture, and then install the fixture on the upper end of the testing machine, so that it naturally droops to the center position, and then install the fixture on the lower end of the testing machine.
6.3 Apply load in a balanced manner at a loading speed of 10 to 15 mm/min until the sample breaks, and read the load value when the sample breaks. 7 Calculation
7.1 Use formula (1) to calculate the tensile strength of impermeable graphite block. , unit: MPa.2
- load value when the sample breaks, N;
Where: P-
HG/T2642-94
D- sample diameter, mm
7.2 Use formula (2) to calculate the tensile strength a of impermeable graphite tube, unit: MPa. 4P
Fill (D1-d2)
Where: P—load value when the sample breaks, N; D—sample outer diameter, mm;
—sample inner diameter, mm,
Use formula (3) to calculate the tensile strength a of the adhesive casting, unit: MPa.7.3bzxz.net
Where: P—load value when the sample breaks, N; D-sample width, mm
h-sample thickness, mm.
8Test results and test report
The test result processing and test report shall be additionally explained in accordance with the relevant provisions of GB/T13465.1:
This standard is proposed by China National Chemical Equipment Corporation and is under the jurisdiction of the National Technical Committee for Standardization of Metal Chemical Equipment. This standard was drafted by the Chemical Machinery Research Institute of the Ministry of Chemical Industry. The main drafters of this standard are Zhou Jie and Yang Taohe. From the date of implementation of this standard, the original standard HG5-1329-80 of the Ministry of Chemical Industry "Test Method for Tensile Strength of Impermeable Graphite Materials" shall be invalid. (1)
HG/T2642-94
Appendix A
Tensile Test Fixture for Impermeable Graphite Blocks
(Supplement)| |tt||【Upper clamp; 2-zipper; 3-pull ring; 4-pull bolt; 5-fastening ring: 6-upper fixture; 7-stone block test grid; 8-lower fixture: 9-lower clamp 264294
Appendix B
Impermeable graphite tube tensile test specimen fixture
(supplement)
1-Upper clamp: 2-zipper: 3-pull ring: 4-pull bolt; 5-fastening ring; 6-upper fixture; 7-nylon sleeve: 8-graphite tube test specimen ; 9—Lower fixture: 10~Lower clamp HG/T2642-94
Appendix C
Tensile specimen fixture for adhesive castings
(Supplement)
Upper clamp: 2—zipper; 3-pull ring; 4—tensile splint: 5—fixing block; 6—nut; 7—explosion bolt; 8—sample: 9—Lower clamp People's Republic of China
Chemical industry standard
Impermeable graphite material Test method for tensile strength of materials HG/T2642-94
China National Chemical Equipment Corporation
Postal code 100011
Printed by Beijing Institute of Chemical Technology Printing Factory
Copyright reserved
880×1230
First edition in June 1995
No reproduction
12,000 words
First printing in June 1995
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.