Home > JB > JB 20007.2-2004 Oral liquid bottle filling linkage line ultrasonic cleaning machine
JB 20007.2-2004 Oral liquid bottle filling linkage line ultrasonic cleaning machine

Basic Information

Standard: JB 20007.2-2004

tandard name: Oral liquid bottle filling linkage line ultrasonic cleaning machine

Standard category:Machinery Industry Standard (JB)

state:in force

release date:2004-02-05

Implementation date:2004-06-01

standard classification number

Standard ICS number:11.120.30

Standard Classification Number:Medicine, health, labor protection>>Pharmaceutical, safety machinery and equipment>>C92 pharmaceutical processing machinery and equipment

associated standards

alternative situation:Replaced YY 0217.2-1995

Publication information

publishing house:China Planning Press

Publication date:2004-06-01

other information

drafter:Yuan Jingzhou, Xin Yi, Wang Zhaoli

Drafting unit:Beijing Aerospace Wanda High-Tech Development Center

Focal point unit:Pharmaceutical Equipment Standardization Committee

Proposing unit:China Pharmaceutical Equipment Industry Association

Publishing department:National Development and Reform Commission

Introduction to standards:

This standard specifies the classification and labeling, requirements, test methods, inspection rules and signs, instructions for use, packaging and storage of ultrasonic cleaning machines. JB 20007.2-2004 Oral liquid bottle filling linkage line ultrasonic cleaning machine JB20007.2-2004 Standard download and decompression password: www.bzxz.net

Some standard content:

JB | Linkage line
Antibiotic glass bottle powder dispensing linkage line
Linear plunger filling machine
Released on 2004-02-05
Implemented on 2004-06-01| |tt||National Development and Reform Commission released
ICS11.120.30
C92
JB
Pharmaceutical Machinery Industry Standard of the People's Republic of China JB20007.2--2004|| tt||Replace YY0217.2—1995
Oral liquid bottle filling linkage line
Ultrasonic cleaning machine
Production line for filling oral liquid Ultra-sonic washer2004-02-05 Released| |tt||2004-06-01 Implementation
Released by the National Development and Reform Commission
Foreword
Scope
2 Normative Reference Documents
3 Categories and marking
4 requirements
5 test methods
6 inspection rules
7 marks, instructions for use, packaging and storage items
times||tt| |JB20007.2—2004
14
15
15
15
16
17bzxZ.net
18|| tt | | 19 | | tt | | 13 | , GB/T1.2-2002 Standardization Work Guide requirements, revision of YY0217.2-1995 "Oral Liquid Bottle Ultrasonic Cleaning Machine." This standard replaces YY0217.2-1995 from the date of implementation. Compared with YY0217.2-1995, the main technical content changes of this standard are as follows: a) The main chapters and clauses of YY0217.2-1995 are deleted: 3.2, 3.3;
4.1.2.4.3.2, 4.3.3.4 .5.6.4.6;5.2, 5.3.1, 5.7;
6.2.2.2;
7.3;
Additional notes.
b) Revised the main chapters of YY0217.2--1995, Articles: Chapter 1;
Chapter 2;
3.1;
4.1, 4.2, 4.3, 4.4, 4.5;
5.3,5.4,5.5,5.8.5.9.5.10~5.13;6.2.1.1.6.2.2.1b.6.2.2.3;
7.1.2, 7.2, 7.4 .
c) Mainly added chapters and clauses in this standard:
See 4.2, 4.4, 4.5.4.6.1, 4.6.3, 4.7.4~4.7.8, see 5.1, 5.3.2, 5.3.3
See 6.2.2.3 and 7.2.
This standard is proposed by China Pharmaceutical Equipment Industry Association. This standard is under the jurisdiction of the Pharmaceutical Equipment Industry Standardization Technical Committee. This standard was drafted by: Beijing Aerospace Wanda High-Tech Development Center. The main drafters of this standard: Yuan Jingzhou, Xin Yi, Wang Zhaoli. 14
1 Scope
Oral liquid bottle filling linkage line ultrasonic cleaning machine JB20007.2-2004
This standard specifies the classification and marking, requirements, test methods, Inspection rules and markings, instructions for use, packaging, and storage.
This standard applies to ultrasonic cleaning machines for oral liquid bottles and antibiotic bottles (hereinafter referred to as cleaning machines). 2 Normative reference documents
The provisions in the following documents become provisions of this standard through reference in this standard. For dated referenced documents, all subsequent amendments (excluding corrigenda) or revisions do not apply to this standard. However, parties reaching an agreement based on this standard are encouraged to study whether to use the latest versions of these documents. For undated referenced documents, the latest edition applies to this standard. GB/T191 Pictorial signs for packaging, storage and transportation
GB2641 Controlled antibiotic glass bottles
GB/T5226.1—2002 Mechanical safety mechanical and electrical equipment Part 1: General technical conditions GB/T6388 Transport packaging dispatch and receipt Cargo Marking
GB/T9969.1 General Provisions for Instructions for Use of Industrial Products GB/T10111 Method of Random Sampling Using Random Numbers CB/T13306 Labeling
General Technical Conditions for Packaging of Mechanical and Electrical Products
GB/T13384
GB/T16769 Method for measuring noise sound pressure level of metal cutting machine tools YY0056 Controlled oral liquid bottles
Drug Administration Pharmacopoeia of the People's Republic of China (2000 Edition) National Pharmacopoeia Commission 3 Classification and Labeling
3.1 Classification
The cleaning machine uses ultrasonic cleaning.
3.2 Model
3.2.1 The model of the cleaning machine should comply with the regulations of YY/T0216. 3.2.2 Model mark:
15
JB20007.2—2004
YLCX
3.2.3 Marking example:
Main parameters: controlled oral liquid Bottle specification (mL) product type and feature code: C - ultrasonic, machine. 4 Requirements
4.1 Working conditions
4.1.1 Ambient temperature: 18℃~28℃.
4.1.2 Ambient air cleanliness: Class 100,000. 4.1.3 Cleaning water source: Comply with the relevant regulations in the "Pharmacopoeia of the People's Republic of China" (2000 edition), the pressure is 0.2MPa~0.4MPa. 4.1.4 Cleaning gas source: After oil removal, water removal and purification treatment, the pressure is 0.35MPa~0.5MPa. 4.1.5 The temperature of the cleaning fluid should be automatically controlled between 40°C and 60°C. 4.2 Material requirements
4.2.1 The parts in the cleaning machine that come into contact with water should be made of stainless, non-toxic, corrosion-resistant and chemically stable materials, and have corresponding material certificates.
4.3 Appearance requirements
4.3.1 The outer surface of the cleaning machine should be flat and smooth, without defects such as unevenness, burrs and obvious scratches. 4.3.2 The nameplates, warning signs, function identification marks and grounding symbols installed on the cleaning machine should be complete and effective, durable, clear and easy to remember.
4.4 Structural requirements
4.4.1 The water and gas purification filters in the cleaning machine should use environmentally friendly filters. 4.4.2 Argon arc welding is used for pipeline welding, and pipeline connections should be easy to clean. 4.4.3 The cleaning station should have a sink and be equipped with a transparent shield. 4.4.4 The cleaning machine should have drainage and exhaust ports; the sink should be equipped with a drain valve. 4.4.5 The working surface of the cleaning machine should have a vertical height adjustment device and a connection transition device. 4.5 Functional requirements
4.5.1 The cleaning machine should meet the production speed requirements, and the speed is adjustable within the specified range. 4.5.2 Control function: control speed.
4.5.3 Display function: display production speed and total output, display temperature and pressure of cleaning fluid. 4.5.4 Interlock function: When the pressure and temperature of the disinfectant fluid do not reach the set values, the machine should not be turned on. When the outlet bottles accumulate, it should automatically stop. 4.5.5 Protection function:
4.5.5.1 Set the minimum water level in the washing machine sink, and the machine will not start when the water level is lower than this level. 16
4.5.5.2 When the cleaning machine is working normally, it should automatically stop when the transparent guard is opened. 4.6 Performance requirements
4.6.1 The piping system should not leak, and the reduction gearbox should have no oil leakage. 4.6.2 The noise of the cleaning machine during load operation shall not exceed 80dB(A). JB 20007.2—2004
4.6.3 During the operation of the cleaning machine, the transmission device should ensure that the bottles enter the bottle washing station accurately, and the whole machine operates stably and reliably without bottle jamming.
4.6.4. The surface of the cleaned bottle has no stains, flow marks and thin layer of gloss. After filling the antibiotic bottle with water for injection, there should be no foreign matter in the bottle. Clarity should comply with the relevant requirements in the "Pharmacopoeia of the People's Republic of China" (2000 edition). 4.6.5 The damage rate should not be greater than 0.5%.
4.7 Electrical system safety requirements
4.7.1 The continuity of the protective grounding circuit of the electrical system shall comply with the provisions of 19.2 in GB5226.1-2002. 4.7.2 The insulation resistance of the electrical system should comply with the provisions of 19.3 in GB5226.1-2002. 4.7.3 The withstand voltage of the electrical system shall comply with the provisions of 19.4 in CB5226.1-2002. 4.7.4 The protective grounding circuit of the electrical system should comply with the provisions of 8.2 in GB5226.1-2002. 4.7.5 The buttons of the electrical system should comply with the provisions of 10.2 in GB5226.1-2002. 4.7.6 The indicator lights and displays of the electrical system should comply with the provisions of 10.3 in CB5226.12002. 4.7.7 The wiring of the electrical system should comply with the provisions of Chapter 14 of GB5226.[-2002]. 4.7.8 The markings, warning signs and project codes of the electrical system should comply with the provisions of Chapter 17 of GB5226.1-2002. 5 Test methods
5.1 Working condition test
Check the filter device of the water and air supply system of the cleaning machine. Use a grade 2 industrial thermometer to measure the temperature of the cleaning fluid, and a grade 2.5 pressure gauge to detect the pressure of the cleaning fluid and air source.
5.2 Material, appearance and structure inspection
Visually inspect the material certification data, machine appearance and structure of the materials used in the cleaning machine. 5.3 Functional inspection
5.3.1 Production speed test:
After the cleaning machine is operated under load, use a stopwatch to measure at the rated speed. 5.3.2 Control function test;
Before the cleaning machine leaves the factory, simulate normal production procedures for commissioning and inspection. 5.3.3 Display function test:
Visually inspect the function of the display instrument during the operation test. 5.3.4 Interlock function test:
a) When the cleaning fluid pressure is adjusted to be lower than the set value, the visual inspection machine should stop: b) When the cleaning fluid temperature is adjusted lower than the set value, the visual inspection machine should Shutdown: c) When too many bottles accumulate at the bottle outlet, the machine should stop. 5.3.5 Protection function test:
17
JB20007.2—2004
a) The water level in the washing machine sink is lower than the rated water level, and the machine does not start according to visual inspection. b) When the washing machine is working, Open the transparent shield and visually check that the machine should be shut down. 5.4 Performance test
5.4.1 No-load test:
a) During no-load operation, there should be no oil dripping from the reduction gearbox by visual inspection, and there should be no abnormal noise by ear. b) After no-load operation, use a secondary industrial thermometer to check the surface temperature rise of the reduction gearbox and motor. It should be less than 35°C. 5.4.2 Load test:
During the load test, the movements of each process are sensitive and reliable. There must be no water or air leakage at the joints of each pipeline. 5.4.3 Noise test:
When the cleaning machine is under load operation, use a sound level meter to test according to the regulations of GB/T16769. 5.4.4 Cleaning quality inspection:
After sterilizing the bottles, take samples and inspect the appearance and clarity according to the "Pharmacopoeia of the People's Republic of China" (2000 edition). 5.5 Determination of breakage rate
When the cleaning machine is running at rated speed with load, count the total number of broken bottles and the total number of bottles entered within 30 minutes. Calculate according to formula (1): broken bottle rate (%): ||tt ||5.6 Electrical system quality inspection
Total number of broken bottles
Total number of incoming bottles
×100+
(1)
5.6.1 Electrical system The continuity, insulation resistance and withstand voltage inspection of the protective grounding circuit shall be carried out in accordance with the provisions of 19.2, 19.3 and 19.4 in GB5226.1-2002 respectively.
5.6.2 The protective grounding circuit, buttons, indicators and displays, wiring, markings, warning signs and project codes of the electrical system shall be in accordance with GB5226.1-2002 8,2, 10.2, 10.3 and 14 respectively. Chapter 17 and Chapter 17. 6 Inspection Rules
6.1 Each cleaning machine must pass the quality inspection and be accompanied by a product certificate before it can leave the factory. 6.2 Inspection classification
The inspection of cleaning machines is divided into factory inspection and type inspection. 6.2.1 Factory inspection
6.2.1.1 Factory inspection shall be carried out one by one according to the requirements in Table 1. Those who pass the test shall be allowed to leave the factory, and shall be accompanied by the product certificate Table 1 Factory inspection items
Category
General items
Main items
Inspection items
4.2,4.3,4.4, 4.5.1, 4.5.3
4.5.2, 4.5.4, 4.5.5, 4.6.14.6.5, 4.76.2.1.2 During the inspection process of the cleaning machine, if unqualified products are found, they should be returned for repair and then submitted for inspection. If they are still unqualified, then Determined as unqualified products
6.2.2 Type inspection
6.2.2.1 Type inspection shall be carried out when one of the following situations occurs: 18
a) Product trial shaping or transformation When the factory is in production: b) When there are major changes in the structure, materials, and processes of the product: e) When the product resumes production after 2 years of suspension; d) When the national quality supervision agency proposes a requirement for type inspection. 6.2.2.2 Sampling: | |tt | 6.2.2.3 Judgment rules:
During the type inspection, if one of the electrical safety performance of protective grounding circuit continuity, insulation resistance, and withstand voltage fails, the product will be judged to have failed the type inspection. If one of the other items fails, the unqualified item should be retested twice. If it still fails, the product will be judged to have failed the type inspection.
7 Logo, Instructions for Use, Packaging and Storage 7.1 Logo
7.1.1: Each cleaning machine has a product label fixed at the position specified on the drawing, and the label should comply with the regulations of GB/T13306. 7.1.2 The label of the cleaning machine should include the following: a) product name and model:
b) manufacturer name;
c) product number and manufacturing date;
d) Main parameters;
e) product standard number.
7.1.3 Storage and transportation markings should comply with the regulations of GB/T191. 7.2 Instructions for use
Product instructions for use shall comply with the provisions of CB/T9969.1. 7.3 Packaging
7.3.1 Product packaging should comply with the regulations of GB/T13384. 7.3.2 The packaging box should have the following accompanying documents: a) Product certificate;
b) Product instruction manual:
c) Packing list;
d) List of accompanying accessories:
e) Material certificate and instrumentation inspection certificate specified in this standard. 7.4 Storage
After packing the cleaning machine, it should be stored in a corrosive gas-free, dry, well-ventilated indoor or sheltered place, and should not be tilted or pressed heavily.
19
2 Material, appearance and structure inspection
Visually inspect the material certification data, machine appearance and structure of the materials used in the cleaning machine. 5.3 Functional inspection
5.3.1 Production speed test:
After the cleaning machine is operated under load, measure it with a stopwatch at the rated speed. 5.3.2 Control function test;
Before the cleaning machine leaves the factory, simulate normal production procedures for commissioning and inspection. 5.3.3 Display function test:
Visually inspect the function of the display instrument during the operation test. 5.3.4 Interlock function test:
a) When the cleaning fluid pressure is adjusted to be lower than the set value, the visual inspection machine should stop: b) When the cleaning fluid temperature is adjusted lower than the set value, the visual inspection machine should Shutdown: c) When too many bottles accumulate at the bottle outlet, the machine should stop. 5.3.5 Protection function test:
17
JB20007.2—2004
a) The water level in the washing machine sink is lower than the rated water level, and the machine does not start according to visual inspection. b) When the washing machine is working, Open the transparent shield and visually check that the machine should be shut down. 5.4 Performance test
5.4.1 No-load test:
a) During no-load operation, there should be no oil dripping from the reduction gearbox by visual inspection, and there should be no abnormal noise by ear. b) After no-load operation, use a secondary industrial thermometer to check the surface temperature rise of the reduction gearbox and motor. It should be less than 35°C. 5.4.2 Load test:
During the load test, each process operates sensitively and reliably. There must be no water or air leakage at the joints of each pipeline. 5.4.3 Noise test:
When the cleaning machine is under load operation, use a sound level meter to test according to the regulations of GB/T16769. 5.4.4 Cleaning quality inspection:
After sterilizing the bottles, take samples and inspect the appearance and clarity according to the "Pharmacopoeia of the People's Republic of China" (2000 edition). 5.5 Determination of breakage rate
When the cleaning machine is running at rated speed with load, count the total number of broken bottles and the total number of bottles entered within 30 minutes. Calculate according to formula (1): broken bottle rate (%): ||tt ||5.6 Electrical system quality inspection
Total number of broken bottles
Total number of incoming bottles
×100+
(1)
5.6.1 Electrical system The continuity, insulation resistance and withstand voltage inspection of the protective grounding circuit shall be carried out in accordance with the provisions of 19.2, 19.3 and 19.4 in GB5226.1-2002 respectively.
5.6.2 The protective grounding circuit, buttons, indicators and displays, wiring, markings, warning signs and project codes of the electrical system shall be in accordance with 8,2, 10.2, 10.3 and 14 of GB5226.1-2002 respectively. Chapter 17 and Chapter 17. 6 Inspection Rules
6.1 Each cleaning machine must pass the quality inspection and be accompanied by a product certificate before it can leave the factory. 6.2 Inspection classification
The inspection of cleaning machines is divided into factory inspection and type inspection. 6.2.1 Factory inspection
6.2.1.1 Factory inspection shall be carried out one by one according to the requirements in Table 1. Those who pass the test shall be allowed to leave the factory, and shall be accompanied by the product certificate Table 1 Factory inspection items
Category
General items
Main items
Inspection items
4.2,4.3,4.4, 4.5.1, 4.5.3
4.5.2, 4.5.4, 4.5.5, 4.6.14.6.5, 4.76.2.1.2 During the inspection process of the cleaning machine, if unqualified products are found, they should be returned for repair and then submitted for inspection. If they are still unqualified, then Determined as unqualified products
6.2.2 Type inspection
6.2.2.1 Type inspection shall be carried out when one of the following situations occurs: 18
a) Product trial shaping or transformation When the factory is in production: b) When there are major changes in the structure, materials, and processes of the product: e) When the product resumes production after 2 years of suspension; d) When the national quality supervision agency proposes a requirement for type inspection. 6.2.2.2 Sampling: | |tt | 6.2.2.3 Judgment rules:
During the type inspection, if one of the electrical safety performance of protective grounding circuit continuity, insulation resistance, and withstand voltage fails, the product will be judged to have failed the type inspection. If one of the other items fails, the unqualified item should be retested twice. If it still fails, the product will be judged to have failed the type inspection.
7 Logo, Instructions for Use, Packaging and Storage 7.1 Logo
7.1.1: Each cleaning machine has a product label fixed at the position specified on the drawing, and the label should comply with the regulations of GB/T13306. 7.1.2 The label of the cleaning machine should include the following: a) product name and model:
b) manufacturer name;
c) product number and manufacturing date;
d) Main parameters;
e) product standard number.
7.1.3 Storage and transportation markings should comply with the regulations of GB/T191. 7.2 Instructions for use
Product instructions for use shall comply with the provisions of CB/T9969.1. 7.3 Packaging
7.3.1 Product packaging should comply with the regulations of GB/T13384. 7.3.2 The packaging box should have the following accompanying documents: a) Product certificate;
b) Product instruction manual:
c) Packing list;
d) List of accompanying accessories:
e) Material certificates and instrumentation inspection certificates specified in this standard. 7.4 Storage
After packing the cleaning machine, it should be stored in a corrosive gas-free, dry, well-ventilated indoor or sheltered place, and should not be tilted or pressed heavily.
19
2 Material, appearance and structure inspection
Visually inspect the material certification data, machine appearance and structure of the materials used in the cleaning machine. 5.3 Functional inspection
5.3.1 Production speed test:
After the cleaning machine is operated under load, use a stopwatch to measure at the rated speed. 5.3.2 Control function test;
Before the cleaning machine leaves the factory, simulate normal production procedures for commissioning and inspection. 5.3.3 Display function test:
Visually inspect the function of the display instrument during the operation test. 5.3.4 Interlock function test:
a) When the cleaning fluid pressure is adjusted to be lower than the set value, the visual inspection machine should stop: b) When the cleaning fluid temperature is adjusted lower than the set value, the visual inspection machine should Shutdown: c) When too many bottles accumulate at the bottle outlet, the machine should stop. 5.3.5 Protection function test:
17
JB20007.2—2004
a) The water level in the washing machine sink is lower than the rated water level, and the machine does not start according to visual inspection. b) When the washing machine is working, Open the transparent shield and visually check that the machine should be shut down. 5.4 Performance test
5.4.1 No-load test:
a) During no-load operation, there should be no oil dripping from the reduction gearbox by visual inspection, and there should be no abnormal noise by ear. b) After no-load operation, use a secondary industrial thermometer to check the surface temperature rise of the reduction gearbox and motor. It should be less than 35°C. 5.4.2 Load test:
During the load test, each process operates sensitively and reliably. There must be no water or air leakage at the joints of each pipeline. 5.4.3 Noise test:
When the cleaning machine is under load operation, use a sound level meter to test according to the regulations of GB/T16769. 5.4.4 Cleaning quality inspection:
After sterilizing the bottles, take samples and inspect the appearance and clarity according to the "Pharmacopoeia of the People's Republic of China" (2000 edition). 5.5 Determination of breakage rate
When the cleaning machine is running at rated speed with load, count the total number of broken bottles and the total number of bottles entered within 30 minutes. Calculate according to formula (1): broken bottle rate (%): ||tt ||5.6 Electrical system quality inspection
Total number of broken bottles
Total number of incoming bottles
×100+
(1)
5.6.1 Electrical system The continuity, insulation resistance and withstand voltage inspection of the protective grounding circuit shall be carried out in accordance with the provisions of 19.2, 19.3 and 19.4 in GB5226.1-2002 respectively.
5.6.2 The protective grounding circuit, buttons, indicators and displays, wiring, markings, warning signs and project codes of the electrical system shall be in accordance with 8,2, 10.2, 10.3 and 14 of GB5226.1-2002 respectively. Chapter 17 and Chapter 17. 6 Inspection Rules
6.1 Each cleaning machine must pass the quality inspection and be accompanied by a product certificate before it can leave the factory. 6.2 Inspection classification
The inspection of cleaning machines is divided into factory inspection and type inspection. 6.2.1 Factory inspection
6.2.1.1 Factory inspection shall be carried out one by one according to the requirements in Table 1. Those who pass the test shall be allowed to leave the factory, and shall be accompanied by the product certificate Table 1 Factory inspection items
Category
General items
Main items
Inspection items
4.2,4.3,4.4, 4.5.1, 4.5.3
4.5.2, 4.5.4, 4.5.5, 4.6.14.6.5, 4.76.2.1.2 During the inspection process of the cleaning machine, if unqualified products are found, they should be returned for repair and then submitted for inspection. If they are still unqualified, then Determined as unqualified products
6.2.2 Type inspection
6.2.2.1 Type inspection shall be carried out when one of the following situations occurs: 18
a) Product trial shaping or transformation When the factory is in production: b) When there are major changes in the structure, materials, and processes of the product: e) When the product resumes production after 2 years of suspension; d) When the national quality supervision agency proposes a requirement for type inspection. 6.2.2.2 Sampling: | |tt | 6.2.2.3 Judgment rules:
During the type inspection, if one of the electrical safety performance of protective grounding circuit continuity, insulation resistance, and withstand voltage fails, the product will be judged to have failed the type inspection. If one of the other items fails, the unqualified item should be retested twice. If it still fails, the product will be judged to have failed the type inspection.
7 Logo, Instructions for Use, Packaging and Storage 7.1 Logo
7.1.1: Each cleaning machine has a product label fixed at the position specified on the drawing, and the label should comply with the regulations of GB/T13306. 7.1.2 The label of the cleaning machine should include the following: a) product name and model:
b) manufacturer name;
c) product number and manufacturing date;
d) Main parameters;
e) product standard number.
7.1.3 Storage and transportation markings should comply with the regulations of GB/T191. 7.2 Instructions for use
Product instructions for use shall comply with the provisions of CB/T9969.1. 7.3 Packaging
7.3.1 Product packaging should comply with the regulations of GB/T13384. 7.3.2 The packaging box should have the following accompanying documents: a) Product certificate;
b) Product instruction manual:
c) Packing list;
d) List of accompanying accessories:
e) Material certificates and instrumentation inspection certificates specified in this standard. 7.4 Storage
After packing the cleaning machine, it should be stored in a corrosive gas-free, dry, well-ventilated indoor or sheltered place, and should not be tilted or pressed heavily.
19
4.3,4.4, 4.5.1, 4.5.3
4.5.2,4.5.4,4.5.5,4.6.14.6.5,4.76.2.1.2 During the inspection process, if the cleaning machine is found to be unqualified The product should be returned for repair, and then submitted for inspection after repair. If it is still unqualified, it will be judged as a substandard product
6.2.2 Type inspection
6.2.2.1 When one of the following situations occurs , type inspection should be carried out: 18
a) When the product is trial-made or transferred to the factory for production: b) When the structure, materials, and processes of the product have major changes: e) When the product resumes production after 2 years of suspension; d) When the national quality supervision agency requests type inspection. 6.2.2.2 Sampling: | |tt | 6.2.2.3 Judgment rules:
During the type inspection, if one of the electrical safety performance of protective grounding circuit continuity, insulation resistance, and withstand voltage fails, the product will be judged to have failed the type inspection. If one of the other items fails, the unqualified item should be retested twice. If it still fails, the product will be judged to have failed the type inspection.
7 Logo, Instructions for Use, Packaging and Storage 7.1 Logo
7.1.1: Each cleaning machine has a product label fixed at the position specified on the drawing, and the label should comply with the regulations of GB/T13306. 7.1.2 The label of the cleaning machine should include the following: a) product name and model:
b) manufacturer name;
c) product number and manufacturing date;
d) Main parameters;
e) product standard number.
7.1.3 Storage and transportation markings should comply with the regulations of GB/T191. 7.2 Instructions for use
Product instructions for use shall comply with the provisions of CB/T9969.1. 7.3 Packaging
7.3.1 Product packaging should comply with the regulations of GB/T13384. 7.3.2 The packaging box should have the following accompanying documents: a) Product certificate;
b) Product instruction manual:
c) Packing list;
d) List of accompanying accessories:
e) Material certificate and instrumentation inspection certificate specified in this standard. 7.4 Storage
After packing the cleaning machine, it should be stored in a corrosive gas-free, dry, well-ventilated indoor or sheltered place, and should not be tilted or pressed heavily.
19
4.3,4.4, 4.5.1, 4.5.3
4.5.2,4.5.4,4.5.5,4.6.14.6.5,4.76.2.1.2 During the inspection process of the cleaning machine, if unqualified products are found, they should be returned for repair and then submitted for inspection again. If they are still unqualified, they will be judged as unqualified products.
6.2.2 Type inspection
6.2.2.1 Type inspection should be carried out in any of the following situations:18
a) When the product is trial-formed or transferred to another factory for production; b) When the product structure, material or process has been greatly changed; e) When the product is resumed after being discontinued for 2 years; d) When the national quality supervision agency requires type inspection. 6.2.2.2 Sampling:
JB20007.2—2004
10% of the samples for type inspection shall be selected from the qualified products of factory inspection according to the method specified in GB/T10111, and one shall be tested. 6.2.2.3 Judgment rules:
If one of the continuity of protective grounding circuit, insulation resistance and withstand voltage in the electrical safety performance fails in type inspection, the product shall be judged to fail the type inspection. If one of the other items fails, the unqualified item shall be doubled and retested. If it still fails, the product shall be judged to fail the type inspection.
7 Marking, instruction manual, packaging and compensation 7.1 Marking
7.1.1: Each cleaning machine shall be fixed with a product label in the position specified in the drawing, and the label shall comply with the provisions of GB/T13306. 7.1.2 The label of the cleaning machine shall include the following contents: a) Product name and model:
b) Manufacturer name;
c) Product number and manufacturing date;
d) Main parameters;
e) Product standard number.
7.1.3 Storage and transportation signs shall comply with the provisions of GB/T191. 7.2 Instructions for use
Product instructions for use shall comply with the provisions of CB/T9969.1. 7.3 Packaging
7.3.1 Product packaging shall comply with the provisions of GB/T13384. 7.3.2 The packaging box shall have the following random documents: a) Product certificate;
b) Product instructions for use:
c) Packing list;
d) Random accessories list:
e) Material certificate and instrument inspection certificate specified in this standard. 7.4 Storage
After the cleaning machine is packed, it should be stored in a dry, well-ventilated room or a sheltered place without corrosive gas. It should not be tilted or pressed heavily.
19