title>CB/T 3226-1995 Fixed rectangular windows in the cab - CB/T 3226-1995 - Chinese standardNet - bzxz.net
Home > CB > CB/T 3226-1995 Fixed rectangular windows in the cab
CB/T 3226-1995 Fixed rectangular windows in the cab

Basic Information

Standard ID: CB/T 3226-1995

Standard Name: Fixed rectangular windows in the cab

Chinese Name: 驾驶室固定矩形窗

Standard category:Ship Industry Standard (CB)

state:in force

Date of Release1995-12-19

Date of Implementation:1996-08-01

standard classification number

Standard ICS number:Shipbuilding and offshore structures>>Shipbuilding and offshore structures in general>>47.020.50 Deck equipment and devices

Standard Classification Number:Ship>>Outfitting Equipment>>U26 Deck Accessories

associated standards

alternative situation:CB* 3226-84

Procurement status:Non-equivalent ISO 3903

Publication information

publishing house:China Standards Press

Publication date:1996-08-01

other information

drafter:Zhang Songying, Shao Jinhua, Shao Guoying

Drafting unit:Jiangnan Shipyard, Hudong Shipyard, 603 Institute, etc.

Focal point unit:Jiangnan Shipyard

Proposing unit:China State Shipbuilding Corporation

Publishing department:China State Shipbuilding Corporation

Introduction to standards:

This standard specifies the product classification, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of fixed rectangular windows in the wheelhouse. This standard applies to rectangular windows installed in the wheelhouse and bridge of various ships and offshore buildings for observation and operation in enclosed places. CB/T 3226-1995 Fixed rectangular windows in the wheelhouse CB/T3226-1995 Standard download decompression password: www.bzxz.net

Some standard content:

Ship Industry Standard of the People's Republic of China
CB/T3226-1995
Fixed rectangular windows in the wheelhouse
Published on December 19, 1995
Published by China State Shipbuilding Corporation
Implemented on August 1, 1996
Ship Industry Standard of the People's Republic of China
Fixed rectangular windows in the wheelhouse
This standard adopts the international standard ISO3903 "Shipbuilding and offshore structures 1 Subject content and scope of application" in a non-equivalent manner
CB/T3226-1995
Classification number: U26
Replaces CB3226-84
Ordinary rectangular windows for ships".
This standard specifies the product classification, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of fixed rectangular windows in the wheelhouse (hereinafter referred to as rectangular windows).
This standard applies to rectangular windows installed in the navigation room and bridge of various types of ships and offshore buildings for closed places for observation and operation. 2 Reference standards
GB3385
Packaging, storage and transportation pictorial marking
Toughened safety glass for marine windows and rectangular windows Non-destructive strength test GB/T4942.2 Protection grade of low-voltage electrical enclosure Transport packaging Receiving and shipping marking
GB6388
GB11584
GB11946
CB'/Z54
CB/Z92
CB*/Z343
ISO3434
3 Product classification
Navigation windows Rectangular window sealing gaskets
Toughened safety glass for marine use
Electrolytic galvanizing
Aluminum alloy anodizing treatment
General process for hot-dip galvanizing
Shipbuilding and offshore structures
The types of fixed rectangular windows in the wheelhouse are as shown in Table 1. Type
Heated glass plate for marine rectangular windows
Electric heating glass Bolt-type fixed rectangular window for cab Marine tempered safety glass Bolt-type fixed rectangular window for driving room Electric heating glass Welded fixed rectangular window for cab Marine tempered safety glass Welded fixed rectangular window for cab Note: The heating method of electric heating glass is electric heating wire heating. The structural types and main dimensions of 2BH and BN rectangular windows are as shown in Figure 1 and Table 2. 3.2 China State Shipbuilding Corporation approved the stamping method on December 19, 1995. Main window frame material: Aluminum alloy. Carbon cable steel. Implementation on August 1, 1996. CB/T3226-1995. 1-Main window frame: 2-Glass pressure plate: 3-Glass: 4-Sealing diagram: 5-Countersunk screw: 6-Note: The outer fillet radius of the shoulder r: = r + 24mm; the outer fillet radius of the flange rs = r + 65mm. public
800X630
800×710
900×630
900×710
900×800
86781 030
87581030
88481030
6781330
1200X6301248
1200×710| 1248
7581330
88481330
1200×8001248
1500×7101
7581630
1500x8001548
38481630
1800×7101848
7581930
1800×8001 848
38481930
Glass installation coffin
821731
9301521
8401821
1800×9001848948193010301821921CB/T3226-1995
Glass pressure plate
850680
850760
950760
950|850
1550850
1850850
1850950
Glass size
Exterior size
816X646
816X726bzxZ.net
916X646
916×726
916×816
1216×646
Surrounding wall opening size
852×682
852×762
952×682
952X7 62
952X852
1252×682
1216x7261081
1216×816
1516×726
1516×816
1816×726
1816×816
1816×916
Mounting bolts
Number of threads
2828.128.7
2828.230.0||tt ||3030.932.9
3033.936.1
3041.644.0
252×762
2144M12
1252×852
1552×762
1552×852
1852×762
1852X852
1852X952
Note: If a snowplow is installed on the rectangular window of the cab, the glass should have a corresponding opening size. However, if the rectangular window of the cab is electrically heated glass, a snowplow cannot be installed.
3.3 The structural types and main dimensions of WH and WN rectangular windows shall be in accordance with Figure 2 and Table 3. 3
CB/T3226-1995
Nail spacing 75
1-Main orange; 2-Glass pressure plate: 3 Glass: 4-Sealing surface: 5-Countersunk screw nominal
800×630
800×710
900×630
900×710
900×800
12 00×630
1200×710
1200×800
1500×710
1500×800
1800×710
1800× 800
1800×900
main window frame
848678
848758
948758
948848
1848948
Glass installation
824654
824734
924654
924734
924824
224824
1824924
CB/T3226-1995
Glass pressure plate
External size
816×646
816×726
916×646| |tt||916×726
916×816
1216×646
1216×726
1216×816
1516×726
1516×816
1816×726
1816×816
1816X916
Note: If a snowplow is installed on the rectangular window of the cab, the glass should be opened with the corresponding size, but the cab 3.4 The main parts surface dimensions are as shown in Figure 3 to Figure 7
Figure 3BH, BN type window main window frame cut surface diagram
Drawing wall opening dimensions
852×682
852×762
952×682
952×762
952×852
1252×682
1252X762
12 52×852
1552×762
1552×852
1892×762
1852×862
1852×952
Then a snow sweeper cannot be installed
Figure 4 Sectional view of the main window frame of WH and WN type windows
Figure 5 Sectional view of the glass pressure plate of BH and BN type windows
Note: t is the thickness of the glass.
3.5 Glass
CB/T3226-1995
Figure 6 Sectional view of WH and WN type window glass pressure plate
Figure 7 Sectional view of sealing ring
3.5.1 The marine toughened safety glass installed in the fixed rectangular windows of the navigation cab shall comply with the provisions of GB11946, and its thickness shall be in accordance with the provisions of Table 2 and Table 3.
The electrically heated glass installed in the fixed rectangular windows of the navigation cab shall comply with the provisions of ISO3434, and the power load required by the glass and its parameters shall be in accordance with Table 4.
Power supply (current frequency system)
Overheat protection
Minimum power load, W/dm?
AC single phase
AC three phase
Power supply (current frequency system)
220/380
CB/T3226-1995
Continued Table 4
Overheat protection
Minimum power load, W/dm
Note: G indicates group regulator, S indicates single regulator. For example, if the minimum power load is 12W/dm, the power supply is AC single phase, the voltage is 220V, the frequency is 50Hz, and the overheat protection device is a single regulator, its power load parameter is 12S13. Marking example
Nominal size 900mm×630mm marine tempered safety glass, bolt-type fixed rectangular window in the wheelhouse. Cab window BN-900X630CB/T3226-1995Nominal size 1500×800Electric heating glass, electric heating wire heating, minimum power load is 12W/dm, overheat protection device is group regulator, power supply is AC single phase, voltage 220V, frequency 60Hz (12G14)Welded cab rectangular window. Cab window WH-1500×800
CB/T3226-1995
5Technical requirements
CB/T3226-1995
Main parts and materials of cab fixed rectangular window are as shown in Table 5. Table 5
Parts Name
Main Window Frame
Glass Pressure Plate
Sealing Ring
Countersunk Lamp
Aluminum Alloy
Carbon Steel
Aluminum Alloy
Copper Alloy
Marine Tempered Safety Glass
Electric Heating Glass
Nitroprene
Stainless Steel
Q235-A
HMn58-2
1Cr18Ni9
Standard No.
GB3190--82|| tt||GB700—88
GB3190-82
GB2041—89
GB11946-89
ISO3434—92
GB11584—89
GB1220-84
Extruded profiles
Extruded profiles
The connecting welds of the main window frame and the glass pressure plate should be free of pores and sand holes, and the weld surface should be smooth. Aluminum welding uses argon arc. The surface of aluminum parts should be anodized according to CB/Z92. The surface of steel parts should be galvanized according to CB'/Z54 or CB'/Z343. Protective film should be applied on both sides of the glass.
The dimension tolerance requirement of the outer corridor of the window seat shoulder is ±1mm. 5.7
Requirements for installing glass: The gap between the glass edge and the glass groove should be consistent. 5.8 The surface roughness R of the main window frame, glass pressure plate and other extruded profiles should not be greater than 12.5um. 5.9
For technical requirements of electrically heated glass, please refer to ISO3434. 5.9.1
The edge of electrically heated glass should be protected. The edge protection should be bonded to the edge and its thickness should not exceed 2mm, see Figure 8. Figure 8
1-Pallet; 2-Cover 3-Heating element; 4-Intermediate layer 5-Edge protection layer 5.9.2 Power load
In water cities outside the North and South Poles, the power load of the glass defogger and defroster equipment under normal wind speed and standard atmospheric pressure 20/65 shall be as specified in Table 6.
CB/T3226-1995
Power load, W/dm
Outdoor temperature
-12℃
-40℃
Note: When a ship sails to the polar regions and requires a higher power load, the window manufacturer or the manufacturer of the heated glass should be consulted to increase the power load provided by the electrically heated glass to meet the use requirements. 5.9.3 Power supply
The voltage and frequency of the feeder circuit of the electrically heated window should be consistent with the normal and continuous power supply voltage and frequency provided by the switchboard on board. For details, see Table 4.
5.9.4 Electrical connection
A moisture-proof junction box should be installed between the heating circuit and the feeder circuit. The junction box should meet the IP22 protection requirements specified in GB/T4942.2. These junction boxes should be fixed on the inner edge of the heated window. During installation, necessary protective measures should be taken against electric shock, insulation and grounding. If, in special cases, the junction box is installed on the glass window frame, the glass should be equipped with a suitable cable. 5.9.5 Overheat protection
When the surface temperature of the glass reaches +40, the heated window should be equipped with a thermal shutdown device. For this purpose, the heated window should be equipped with a temperature limiting device (i.e. regulator):
a Single-piece regulator (S): The regulator (such as a temperature sensor) is directly fixed on the inner edge of the glass. It only affects the relevant glass and is also a component of the original equipment.
b. Group regulator (G): An independent regulating device that is not directly fixed on the window and is appropriately connected by several pieces of glass. When ordering, you must understand the model and number of these regulators. 6 Test methods
6.1 Flushing test
After the rectangular window is installed on the simulated bulkhead or loaded on board, a hose with a nozzle diameter of not less than 12.5mm is used, the pressure is not less than 250kPa, the flushing distance does not exceed 1.5m, the flushing time is 3min, and there should be no water marks on the inspected part of the window after flushing. 6.2 Performance test and mechanical strength test.
6.2.1 Performance tests of electrically heated glass such as electrical performance test, chemical performance test, immersion test, etc. shall be carried out in accordance with ISO3434 requirements. 6.2.2 Performance tests of marine tempered safety glass and mechanical strength tests of electrically heated glass and marine tempered safety glass shall be carried out in accordance with GB3385 requirements.
6.3 Insulation test
The insulation test of the electrically heated driving window shall be carried out, and the insulation resistance between the heating element and the temperature sensor, the heating element and the frame, and the temperature sensor and the frame shall not be less than 50MQ.
7 Inspection rules
7.1 Before leaving the factory, the appearance of each window shall be inspected in accordance with the provisions of this standard. 7.2 The manufacturer shall conduct a flushing test on all rectangular windows in accordance with the provisions of Article 6.1. 7.3 For heating series windows, performance tests and mechanical strength tests shall be conducted on each window in accordance with the provisions of Article 6.2 and insulation tests shall be conducted on each window in accordance with the provisions of Article 6.3. 9
CB/T3226—1995
7.4 If a rectangular window undergoing testing fails the test, it is allowed to be tested again after correction, and it can only leave the factory after passing the re-inspection. If the re-inspection fails three times, the window shall be scrapped. 8 Marking
8.1 Rectangular windows shall have the following markings:
Manufacturer name or code;
Product model and standard number;
Manufacturing date or production batch number;
Inspection pass stamp.
8.2 The window glass should be stamped with the glass manufacturer's qualified inspection seal and the glass thickness mark. For example, t=12, marine tempered safety glass.
For example, t=20, the load power is 12W/dm, the AC single-phase power supply is 220V, 50Hz, single-piece adjustment, electric heating glass heated by electric heating wire.
9 Packaging
The finished product can be packaged in calcium plastic corrugated boxes or frame wooden boxes. 9.2
The finished products placed in the box should be clamped in the normal way, the exposed glass surface should be padded with soft packaging materials, and the glass surface should be coated with peelable plastic. 9.3
The markings on the packaging box surface should comply with the provisions of GB6388. 9.4
The packaging box should have obvious "moisture-proof" and "handle with care" words and signs, and the graphics should comply with the provisions of GB191. 9.5
The product certificate should be attached to the packaging box.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.