Basic Information

Standard ID: JB/T 5528-1991

Standard Name: Pressure gauge scale and divisions

Chinese Name: 压力表 标度及分划

Standard category:Machinery Industry Standard (JB)

state:Abolished

Date of Implementation:1992-07-01

Date of Expiration:2006-02-01

standard classification number

Standard Classification Number:Instruments and meters>>Industrial automation instruments and control devices>>N11 temperature and pressure instrument

associated standards

alternative situation:Replaced by JB/T 5528-2005

Publication information

other information

Introduction to standards:

JB/T 5528-1991 Pressure gauge scale and division JB/T5528-1991 standard download decompression password: www.bzxz.net

Some standard content:

Mechanical Industry Standard of the People's Republic of China
JB/T5528--91
Pressure Gauge Scale and Division
1991-07-16 Issued
Ministry of Machinery and Electronics Industry
1992-07-01 Implementation
Subject Content and Scope of Application
Mechanical Industry Standard of the People's Republic of China
Pressure Gauge Scale and Division
This standard specifies the dial scale and division of various pressure gauges. JB/T5528-91
This standard is applicable to the scale design of the dial of various pressure gauges (referred to as instruments) with accuracy levels of 0.1, 0.16, 0.25, 0.4, 1, 1.5, 2.5, 4 and shell nominal diameters of Φ40, 60, $100, Φ150, 200, Φ250mm. Pressure gauges with other types of shells can also be used as a reference.
Those not specified in this standard shall comply with the corresponding provisions of ZBY123. 2
Cited standards
ZBY123 General provisions for the scale of industrial automation instruments 3 Basic requirements for scale
3.1 Scale direction
The scale direction of the instrument shall comply with the following provisions; a. The zero scale line of the pressure gauge shall be located at the left end or lower end of the scale, and scale from zero to the right, clockwise or upward. b. The zero scale line of the vacuum gauge shall be located at the right end or upper end of the scale, and scale from zero to the left, counterclockwise or downward. C. The zero scale line of the pressure vacuum gauge shall be located between the vacuum part scale and the pressure part scale, and the vacuum part scale shall be scaled from zero to the left, counterclockwise or downward, and the pressure part scale shall be scaled from zero to the right, clockwise or upward. 3.2 Zero scale line
The scale reduction of the actual zero scale line of the instrument dial with a stop pin shall not be greater than the absolute value of the basic error limit of the indication. The zero scale line of the instrument dial without a stop pin shall be indicated along the scale baseline, and the indicated range shall not be greater than twice the absolute value of the basic error limit of the indication. 3.3 Scale line
3.3.1 For instruments with accuracy levels of 1, 1.5, 2.5, and 4, the width of the long scale line, the middle scale line, and the short scale line shall not be greater than that specified in Table 1. The long scale line uses a semi-thick line, and the width of the thick part of the semi-thick line shall not be greater than 3 times that specified in Table 1. Table 1
Nominal shell diameter
Approved by the Ministry of Machinery and Electronics Industry on July 16, 1991 Width of scale lines
Implemented on July 1, 1992
JB/T5528-91
3.3.2 For instruments with an accuracy level of 0.4 or higher, the scale lines shall be all fine lines with a width not exceeding 0.2mm. 3.4 Scale units
According to the measuring range of the instrument, the scale units may be MPa (megapascals), kPa (kilopascals) or Pa (pascals). The specific selection of scale units shall be specified by the product standards.
Scale divisions
4.1 The scale diagrams of instruments with a nominal shell diameter of Φ40, (50), @60mm and an accuracy level of 2.5 and 4 shall be as specified in Table 2. Note: The shell diameter in brackets can only be used for pressure gauges used for welding, cutting and similar processes. 4.2 The nominal shell diameter is Φ100mm, and the instrument scales of the accuracy levels 1, 1.5, and 2.5 are as specified in Table 3. 4.3 The nominal shell diameter is 150, Φ200, and Φ250mm, and the instrument scales of the accuracy levels 1, 1.5, and 2.5 are as specified in Table 4. 4.4 The nominal shell diameter is Φ150, 200, and Φ250mm, and the instrument scales of the accuracy level 0.4 are as specified in Table 5. The nominal shell diameter is Φ150, Φ200, and Φ250mm, and the instrument scales of the accuracy level 0.25 are as specified in Table 6. 4.5
The nominal shell diameter is Φ250mn, and the instrument scales of the accuracy levels 0.1 and 0.16 are as specified in Appendix A (reference). Table 2Www.bzxZ.net
Nominal shell diameter Φ40 (50) 60mm, accuracy level 2.5, 4 instrument scale schematic scale range
—10~0
-0.05~0.05
0.5~0.5
Minimum grid value
Total number of grids
Scale range
0:16~0
Minimum grid value
Total number of grids
JB/T5528--91||tt ||Continued Table 2
Scale range
0.12~0.12
—1.2~1.2
~12~12
20~20
Minimum grid value
Total number of grids
5528-91
Continued Table 2
Scale range
-6~0
60~0
-3~3
-30~30
Scale range||t t||Minimum grid value
Total number of grids
JB/T5528-91
Continued Table 2
Scale diagram of instruments with nominal shell diameter Φ100mm and accuracy levels 1, 1.5, and 2.5Minimum grid value
Total number of grids
Scale range
0.03~0.03
-10~0
0.05~0.05
-5~5
Minimum grid value||t t||Total number of grids
JB/T5528-91
Continued Table 3
Scale range
-16~0
0.08~0.08
-25~0
Minimum grid value
Total number of grids
JB/T5528—91
Continued Table 3
Scale range
-0.12~0.12
-12~~12
-4~ 0
-0.2~~0.2
-20~20
Minimum grid value
Total number of grids
JB/T5528--91
Continued Table 3
JB/T5528—91
Nominal shell diameter 150, 9
200, Φ250mm,
Scale schematic scale range of instruments with accuracy levels 1, 1.5, and 2.5
—0.06~0
-6~0
-0.03~0.03| |tt||-0.3~0.3
-3~3
-30~30
-1~0
Minimum grid value
Total number of grids
titjti
Scale range
0.05~0.05
-5~5
16~0
0.08~0.08
-0.1~0.06
Minimum grid value
Total number of grids
JB/T5528--91
Continued Table 4