title>QB/T 2358-1998 Test method for heat seal strength of plastic film packaging bags - QB/T 2358-1998 - Chinese standardNet - bzxz.net
Home > QB > QB/T 2358-1998 Test method for heat seal strength of plastic film packaging bags
QB/T 2358-1998 Test method for heat seal strength of plastic film packaging bags

Basic Information

Standard ID: QB/T 2358-1998

Standard Name: Test method for heat seal strength of plastic film packaging bags

Chinese Name: 塑料薄膜包装袋热合强度试验方法

Standard category:Light Industry Standard (QB)

state:in force

Date of Release1998-03-27

Date of Implementation:1993-07-01

standard classification number

Standard Classification Number:Light Industry, Cultural and Living Goods>>Daily Glass, Ceramics, Enamel, Plastic Products>>Y28 Daily Plastic Products

associated standards

alternative situation:ZB Y28004-86

Procurement status:JIS Z0238-95 NEQ

Publication information

publishing house:China Light Industry Press

Publication date:1993-07-01

other information

drafter:Dong Xiaowei, Gao Yunxue, Yu Yan, Jiang Shulan, Zhao Lili

Drafting unit:Jilin Plastics Research Institute

Focal point unit:National Plastic Products Standardization Center

Proposing unit:Quality Standards Department of China Light Industry Federation

Publishing department:China Light Industry Federation

Introduction to standards:

This standard specifies the test method for the heat seal strength of plastic film packaging bags. This standard is applicable to the determination of the heat seal strength of various plastic film packaging bags. QB/T 2358-1998 Test method for heat seal strength of plastic film packaging bags QB/T2358-1998 Standard download decompression password: www.bzxz.net

Some standard content:

Classification number Y28
Record number 1372-1998
Light Industry Standard of the People's Republic of China
QB/T 235B-98
Plastic film packaging bag
Test method for heat seal strength
Published on March 27, 1998
Published by China Light Industry Association
Implementation on December 1, 1998
Q8/T2358-88
This standard is based on the determination method of heat seal strength of whole material film packaging 213Y28004-36.
The standard is equivalent to the Japanese industry standard JTS7.0238-1995 "Test and method for sealing packaging". This standard adds the oxygen measurement method for the sample and adds the test object to the test report: This standard is issued by the Ministry of Quality Standardization of China Light Industry. The technical standard is issued by the National Center for Standardization of Medical Materials Products. The origin of this standard: Forestry Research Institute of Guangdong Province. The drafters of this standard: Chong Xiaowei, Wu Yunxue, Yu Mo, Jiang Jilan, Qi Li. Implementation of this standard: 2BY2.8004-86:-HiY KiaNh KAca
1 Scope
Light Industry Standard of the People's Republic of China
Test method for heat seal strength of plastic film packaging bags This standard specifies the test method for heat seal strength of plastic film packaging bags. The standard extends the use of various plastic film packaging bags. 2 Reference standards
QB/T2358-98
The following standards contain provisions that constitute the provisions of this standard through the reference in this standard: At the time of publication, the values ​​shown are valid. All standards will be revised, and the parties using this standard should explore the possibility of using the latest versions of the following standards.
G月2918·82Plastic test cycle and test standard environment 3 equipment and quantity are
3.1 Equipment
Pull square test machine, the measured indication should be between 15% and 85% of the full range of the dial: the reading indication error is within 1%3.2 Tool
Vernier caliper, the precision is 0.02mm
True ruler: the accuracy is 1mm.
2 Sample
4.1 Sampling position
As shown in Figure 1, the samples are placed on the side, back, quality part, and bottom of the film air bag of the material bay, and the samples are placed on the hot plate sample of the packaging side, back, quality part, and bottom. 4.2 Shape and
Test width (1520.1) mm, unfolded length ([00±t) mm, if the opening length is not, ([00±1) mm, as shown in Figure 2. Use adhesive tape to bond with the model, so that the test single opening length meets the requirement of (10 spit 1). 4.3 Number of specimens
According to the provisions of 4.1, 10 specimens are taken from each hot plate, and at least cut from 3 material films. 4.4 Specimen measurement
The width of the specimen is measured with a vernier caliper: the length of the specimen is measured with a ruler. 4.5 Conditioning
According to the standard environment and positive belt deviation range specified in G291R, the conditioning time is not less than, and the test is carried out under the same system. Www.bzxZ.net
Approved by China Light Industry General Association on 1998-03-27
199B-12-01 implemented
5 test steps
P constant heat installation
O8/T 2358 - -98
Type pads are installed
(face combination; 2-face heat inclusion: 3 possible parts combination: 4 possible parts heat individual diagram: rubber fence position expensive
qualification points
room length 10001
? Shape and size
#Bag buckle material
Put the sample that has been adjusted at will, with the heat-sealed part as the center, open it", and place the two ends of the test increase on the two fire tools of the test machine. The test axis is perpendicular to the center line of the lower riser. It is required to be tight and suitable, so that the test details can be released or broken in the fire tool before the test. The distance between the tools is 50mm, and the test speed is (30020)rmrumim: Discuss the day when the test breaks If the test is broken in the interlayer, the sample shall be invalid and a new sample shall be taken. The test result shall be the average value of the test strip and the average value of the heat-sealing strength of the part. The unit is A/15mm. The three figures are taken as follows:
YTKANKE
Test report
8/T2358
7.1 Name, material and specification of plastic film packaging bags.7.2 Test strips
The number of test strips at each position of the test strip in the plastic film packaging shall be the average value, maximum value and minimum value.7.3
When the heat-sealing tensile strength of the material film is large, it shall be explained.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.