This standard specifies the technical requirements, test methods, inspection rules, quality assurance period, marking, packaging, transportation and storage requirements of S series electric machines (including S series DC servo motors, commutator series motors, AC/DC motors and DC speed-stabilized motors). This standard applies to S series motors (hereinafter referred to as motors). This series of motors are closed self-cooling commutator motors, suitable for use as actuators in automatic control systems, and can also be used as drive components. JB/T 1377.3-1999 Technical requirements for S series motors JB/T1377.3-1999 Standard download decompression password: www.bzxz.net
Some standard content:
The standard of the People's Republic of China for the production of micro motors JB/T1377.31999 1999-08-064 2000-01-01 JB/T1377.3±1999 This standard is a revision of JB2662-80 "Technical conditions for S series motors". The revision was made with reference to the basic standards and general technical conditions for micro motors. This standard takes into account the actual production conditions and the coordination and consistency with relevant standards. This standard will replace JB2662-80 from the date of implementation. This standard is proposed and managed by the National Micro Motor Standardization Technical Committee. The drafting unit of this standard: Boshan Motor Factory. The main drafters of this standard: Liu Dexue, Lu Zhaotong, and Ma Deli. Boshan Motor Factory is responsible for the interpretation of this standard. 1 JB/T1377.31999 JB2662bzxZ.net This standard specifies the technical requirements, test methods, inspection rules, quality assurance period, marking, packaging, transportation and storage requirements of S series motors (including S series DC servo motors, AC commutator series motors, AC and DC universal motors and DC constant speed motors). This standard applies to S series motors (hereinafter referred to as motors). This series of motors are closed self-cooling commutator motors, which can be used as actuators in automatic control systems and can also be used as drive elements. Reference standards The provisions contained in the following standards constitute the provisions of this standard through reference in this standard. At the time of publication of the standard, the versions shown are valid. All standards will be revised, and parties using this standard should explore the possibility of using the latest versions of the following standards. GB/T2423.3—1993 GB/T7345--1994 GB/T10069.1—1988 GB/T14819—1993 3 Model naming 3.1 Model description 3.1.1 Product name code Use S to indicate the name of the motor. 3.1.2 Frame size Basic environmental test procedures for electrical and electronic products Test Ca: Steady damp heat test method Basic technical requirements for controlled micromotors Determination method and limit value of noise for rotating motors Engineering determination method for noise General technical conditions for electromagnetic DC servo motors Derived code Category code Core length code Frame size Product name code The motor frame number is 1, 2, 3, 5, and 6, which represent the outer diameter of the frame of 50, 70, 85, 108, and 122 respectively. 3.1.3 Iron core length code 1999-08-06 mouse 2000-01-01 JB/T1377.31999 The motor core length is 2 and 4, which represent short iron cores, and 6, 7, and 8, which represent long iron cores. 3.1.4 Category code The motor category is 0, which represents a DC steady-speed motor, 1 and 9, which represent a DC separately excited (shunt excited) motor, 2, which represents an AC series excited motor, 3, which represents a DC series excited reversible motor, 6, which represents a DC compound excited reversible motor, 7, which represents a DC separately excited (shunt excited) motor with a balancing resistor in series in the motor circuit, and 8, which represents an AC/DC general-purpose irreversible motor. 3.1.5 Derivative code Derivative includes structural derivation and performance derivation, and the code is represented by capital letters "A", "B", "C". 4 Technical requirements 4.1 Environmental conditions for use 4.1.1 Ambient temperature -40~+40℃ 4.1.2 Relative humidity of air 90%~95%. 4.1.3 Any installation position. 4.2 Working system Continuous working system of the motor (S1). 4.3 Circuit diagram The circuit diagram is shown in Figures 1 to 8. 4.4 Rated data The rated data of the motor shall comply with the provisions of Table 1 to Table 7, SI Figure 1 Circuit diagram Figure 3 Circuit diagram Figure 2 Circuit diagram Figure 4 Circuit diagram Figure 5 Circuit diagram Figure 7 Circuit diagram JB/T1377.31999 Figure 6 Circuit diagram Figure 8 Circuit diagram DC separately excited (parallel excited) servo motor 3500~5500 3500~5000 3500-5000 3600~4200||tt| |3600~4200 3600-4200 3000~4800 3600~4600 4500~5500 3000~4800 5200~6200 5200~6200 Rated torque Allow forward and reverse Speed difference Double shaft extension Rated speed 4000r/min Rated speed 4000r/min Flange installation S321DA S661LJ S66 1KJ | | tt | | S661QJ | t ||3000-3600 | 4000 3300-4000 3300~4000 850~1050 2200~2700 2400~2800 2400~2800 2400~2800 2000~2500 3000±10% 1500~2000 430~500 2900-3300 2900-3300 The rated data of the motor should be checked in cold state. 2 The motor output is based on torque and the power is for reference only. Rated torque Allowed forward and reverse Speed difference Irreversible Irreversible Double shaft extension Double shaft extension Double shaft extension Flange installation Double shaft extension Foot installation Double shaft extension Double shaft extension Foot installation Rated speed 1800r/min Foot installation Foot installation Double shaft extension Double auxiliary extension, with end shield Rated voltage Rated power JB/T1377.31999 Table 2 DC series reversible motor 35005000 3500~5000 3000~3800 3000~3800 3000~3800 3800-4400 Rated torque The rated data of the motor are checked in the cold state. Except for the motor with tolerance, the lower limit of the speed is used as the rated speed of the motor. 2 The output of the motor is based on torque, and the power is for reference. Table 3 Allowable direct speed difference DC separately excited (parallel excited) motor, current balance resistor connected in series in the armature circuit Rated speed 3800~4400 3800~4400 2500-3000 Rated torque Rated data of the motor When the motor is checked in the cold state, the lower limit of the speed is taken as the rated speed of the motor except for those with tolerance notes. 2 3 The output of the motor is based on torque, and the power is for reference. AC excitation reversible motor Rated current The rated data of the motor is checked in the cold state. Rated speed 4000~5200 40005200 4000~5200 3000~4800 3600~4700 Rated torque 2 Except for those with tolerance, the lower limit of the speed is used as the rated speed of the motor. The output of the motor is based on torque, and the power is for reference. Allowable forward and reverse Speed difference Allowable forward and reverse Speed difference Double shaft extension Flange installation Foot installation Double shaft extension Double shaft extension Rated voltage JB/T1377.31999 AC series-excited irreversible motor Rated power The rated data of the motor should be checked when it is cold. 2The output of the motor is based on torque, and the power is for reference. Rated current Rated speed 2900~3800 Table 6 AC/DC universal series-excited irreversible motor model Current type Rated voltage Rated power The rated data of the motor should be checked when it is cold. 2 The motor output is based on torque, and the power is for reference. Table 7 Rated voltage Rated power Rated current The rated data of the motor are checked when it is cold. 2 The motor output is based on torque, and the power is for reference. Rated current Rated speed 3000~3800 3000~3400 DC steady-speed motor Rated speed 3500±18 4500±22 4500±22 4000±20 4500±22 4500 ±22 4500±22 2600±13 3000 ± 15 3000 ±15 Rated torque Rated torque Wiring diagram number 3S560 factory test is based on the data at 2600r/min. When used at 3000r/min, the working contact distance should be adjusted. 4.5 Structural type 4.5.1 The motor is a closed self-cooling type. Wiring diagram number Double shaft extension 4.5.2 The motor can be made into three installation types: outer circle installation, flange installation and foot installation. The shaft extension can be made into single shaft extension and double shaft extension. 4.6 Appearance and installation dimensions The appearance and installation dimensions of the motor shall comply with the provisions of Figures 9 to 21 and their appendixes. The dimensions without tolerance are basic dimensions. 6 S163JA JB/T1377.31999 Figure 9 Appearance and installation dimensions Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.