title>Inspection of grain and oils—Detection of deoxynivalenol in cereal—Rapid method of colloidal gold technique - LS/T 6110-2014 - Chinese standardNet - bzxz.net
Home > LS > Inspection of grain and oils—Detection of deoxynivalenol in cereal—Rapid method of colloidal gold technique
Inspection of grain and oils—Detection of deoxynivalenol in cereal—Rapid method of colloidal gold technique

Basic Information

Standard ID: LS/T 6110-2014

Standard Name:Inspection of grain and oils—Detection of deoxynivalenol in cereal—Rapid method of colloidal gold technique

Chinese Name: 粮油检验 谷物中脱氧雪腐镰刀菌烯醇测定 胶体金快速测试卡法

Standard category:Grain Industry Standard (LS)

state:in force

Date of Release2014-04-28

Date of Implementation:2014-06-01

standard classification number

Standard ICS number:Food Technology>>67.060 Cereals, pulses and their products

Standard Classification Number:Agriculture and Forestry>>Food and Feed Crops>>B20 Food and Feed Crops Comprehensive

associated standards

Publication information

publishing house:China Standards Press

ISBN:155066·2-27111

Publication date:2014-06-01

other information

drafter:Guo Jian, Wang Zhengping, Liu Jian, Yang Jun, Zhu Xudong, Peng Chao, Liu Yongying, Liu Zheng, Zhang Yan, Yang Weimin, Shao Hui

Drafting unit:Beijing Cereals, Oils and Food Inspection Institute, Hubei Cereals, Oils and Food Quality Monitoring Station, Sichuan Cereals and Oils Central Monitoring Station, Liaoning Cereals and Oils Inspection and Monitoring Institute, Chongqing Cereals and Oi

Focal point unit:National Technical Committee on Grain and Oil Standardization (SAC/TC 270)

Publishing department:State Grain Administration

competent authority:National Technical Committee on Grain and Oil Standardization (SAC/TC 270)

Introduction to standards:

LS/T 6110-2014 Grain and Oil Inspection Determination of Deoxynivalenol in Cereals Colloidal Gold Rapid Test Card Method LS/T6110-2014 |tt||Standard compression package decompression password: www.bzxz.net
This standard specifies the principle, reagents and materials, instruments and equipment, sample preparation, sample determination, result judgment, and positive sample confirmation of the colloidal gold rapid test card detection method for deoxynivalenol. This standard is applicable to the rapid screening of deoxynivalenol in cereals such as wheat and corn.
This standard was drafted in accordance with the rules given in GB/T1.1-2009.
This standard is under the jurisdiction of the National Technical Committee for Standardization of Cereals and Oils (SAC/TC270).
The drafting units of this standard: Beijing Cereals, Oils and Food Inspection Institute, Hubei Cereals, Oils and Food Quality Monitoring Station, Sichuan Cereals and Oils Central Monitoring Station, Liaoning Cereals and Oils Inspection and Monitoring Institute, Chongqing Cereals and Oils Quality Supervision and Inspection Station, Guangxi Cereals and Oils Quality Supervision and Inspection Station, National Grain Administration Standard Quality Center, Henan Province Shangqiu Cereals and Oils Technology Inspection Institute.
The main drafters of this standard: Guo Jian, Wang Zhengping, Liu Jian, Yang Jun, Zhu Xudong, Peng Chao, Liu Yongying, Liu Zheng, Zhang Yan, Yang Weimin, Shao Hui.
The following documents are indispensable for the application of this document. For all dated references, only the dated version applies to this document. For all undated references, the latest version (including all amendments) applies to this document.
GB2761 National Food Safety Standard Limits of Mycotoxins in Food
GB5491 Sampling and Sub-sampling Methods for Grain and Oilseed Inspection
GB/T6682—2008 Specifications and Test Methods for Water Used in Analytical Laboratories
GB/T23503 Determination of Deoxynivalenol in Foods High Performance Liquid Chromatography with Immunoaffinity Chromatography Cleanup

Some standard content:

ICS67.060
Registration No.: 44931-2014
Grain Industry Standard of the People's Republic of China
LS/T6110—2014
Grain and Oils Inspection
Determination of deoxynivalenol in cereals-Rapid method of colloidal goldtechnique2014-04-28 Issued
State Administration of Grain
2014-06-01 Implementation
This standard was drafted in accordance with the rules given in GB/T1.1-2009. This standard is under the jurisdiction of the National Technical Committee for Standardization of Grain and Oils (SAC/TC270). LS/T6110—2014
The drafting units of this standard are: Beijing Cereals, Oils and Food Inspection Institute, Hubei Cereals, Oils and Food Quality Monitoring Station, Sichuan Cereals and Oils Central Monitoring Station, Liaoning Cereals and Oils Inspection and Monitoring Institute, Chongqing Cereals and Oils Quality Supervision and Inspection Station, Guangxi Cereals and Oils Quality Supervision and Inspection Station, National Grain Administration Standard Quality Center, Henan Province Shangqiu Cereals and Oils Technology Inspection Institute. The main drafters of this standard are: Guo Jian, Wang Zhengping, Liu Jian, Yang Jun, Zhu Xudong, Peng Chao, Liu Yongying, Liu Zheng, Zhang Yan, Yang Weimin, Shao Hui. 1 Scope
Cereals and Oils Inspection
Colloidal Gold Rapid Test Card Method for Determination of Deoxynivalenol in Cereals
LS/T6110—2014
This standard specifies the principle, reagents and materials, instruments and equipment, sample preparation, sample determination, result determination, and positive sample confirmation of the colloidal gold rapid test card method for deoxynivalenol. This standard applies to the rapid screening of deoxyfurantoin in cereals such as wheat and corn. 2 Normative references
The following documents are essential for the application of this document. For all references with dates, only the versions with dates apply to this document. For all references without dates, the latest versions (including all amendments) apply to this document. GB2761 National Food Safety Standard Limits of Fungal Toxins in Food GB5491 Grain and Oil Inspection Sampling and Separation Method GB/T6682-2008 Specifications and Test Methods for Water Use in Analytical Laboratories GB/T23503 Determination of Deoxynivalenol in Food Immunoaffinity Chromatography Purification High Performance Liquid Chromatography 3 Principle
This method is based on antigen-antibody reaction, immunogold labeling technology and capillary chromatography technology. The microporous membrane is used as a solid phase carrier. The antibody that can specifically recognize deoxynivalenol is labeled with red or purple colloidal gold particles. The two color bands on the test card membrane are respectively fixed with the deoxynivalenol antigen and the secondary antibody against the mouse antibody. The test results are determined according to the color changes of the color bands. 4 Reagents and Materials
Unless otherwise specified, all reagents used are analytically pure, and the laboratory water should comply with the third-grade water in GB/T6682-2008. 4.1 Deoxynivalenol Colloidal Gold Test Card 1: The performance of the test card shall meet the requirements of Appendix A. Before using test cards of different brands and batches, the performance of the test card shall be determined in accordance with Appendix A. 4.2 Extraction solution: water or special extraction solution that matches the colloidal gold test card. 5 Instruments and equipment
- In addition to conventional laboratory instruments and equipment, the following instruments and equipment should be noted. 1) The deoxynivalenol colloidal gold test card produced by Beijing Huaan Maike Biotechnology Co., Ltd., Shanghai Kuailing Biotechnology Co., Ltd. and Nanchang Boheng Biotechnology Co., Ltd. is currently the most widely used rapid test card. This information is provided only for the convenience of users of this standard and does not represent the recognition of the product by this standard. Any test card that meets the requirements of Appendix A of this standard can be used, LS/T6110—2014
5.1 Balance: Graduation value 0.01g
2 Crusher.
3 Centrifuge: speed 4000r/min,
5.4 Oscillator.
5 Timer.
5 Centrifuge tube.
Sample preparation
Sampling and sub-sampling: in accordance with GB5491,
2 Sample crushing: crush the sample (6.1) to be tested until it passes through a 20-mesh sieve, and mix thoroughly to ensure that deoxynivalenol is evenly distributed.
6.3 Preparation of the solution to be tested: accurately weigh 2.00g of the crushed and mixed sample (6.2) into a centrifuge tube, add 10mL of water or special extract (4.2), oscillate and extract for 3min, centrifuge at 4000r/min for 1min (or let stand), and the supernatant is the solution to be tested. Note: Sample preparation can also be carried out according to the requirements of the test card instruction manual. 7 Sample determination
Use a pipette to slowly add 3 drops of the test solution (6.3) to the sample well of the test card (4.1) (if no liquid moves in the test window within 30 seconds after adding the test solution, add 1 drop of the test solution). Start timing when liquid moves in the test window, and observe the test results within 5min10min.
Note: The quality control color band must appear on the test card during each test, and the test results must be observed within 5min~10min, otherwise the test results will be biased. 8 Result judgment
8.1 Invalid
If the quality control color band does not show color, it means that this test card is invalid and needs to be retested. 8.2 Negative and positive samples
If the quality control color band shows color and the test color band shows color, it is judged as negative. If the quality control color band shows color and the test color band does not show color or the color is very blurred, it is judged as positive.
Confirmation of positive samples
When the positive samples screened by this method need to be confirmed, the judgment should be based on the limit standard of deoxynivalenol specified in GB2761, and the detection method should refer to the method specified in GB/T23503. 2
Technical requirements
Appendix A
(Normative Appendix)wwW.bzxz.Net
LS/T6110—2014
Technical requirements and verification methods of colloidal gold rapid test card for deoxynivalenol in cereals Basic requirements
Working environment requirements
Temperature: 20℃~30℃.
Cross-reaction
No cross-reaction to aflatoxins, zeaflavone, fusin and other mycotoxins. A.1.2
Performance requirements
A.1.2.1 Appearance
The appearance should meet the following requirements:
The surface of the test card should be smooth and flat, with uniform color, and the fiber membrane surface should not have defects such as exposed bottom, bubbles, pitting, wrinkles, brush marks, etc.a)
b) The spot holes should be clean:
c) Text symbols and other signs should be in a straight, clear and correct font. A.1.2.2 Accuracy
The error rate of the test results of the samples should not exceed 15%. For samples with a deoxynivalenol content of 800μg/kg~1200ug/kg, false positives are allowed in the test results, but false negatives are not allowed. A.1.2.3
Stability
The error rate of the test cards of the same batch should not exceed 10%, and the error rate of the test cards of different batches should not exceed 15%. A.2
Verification method
Positive sample determination
Determine the value of positive samples according to the method specified in GB2761. A.2.2
Performance determination
Accuracy
Within the concentration range of 800μg/kg~1200μg/kg deoxynivalenol, select 10 positive samples of different concentrations for determination and calculate the error rate.
LS/T6110—2014
Stability
A.2.2.2.1
Batch stability
Randomly select 3 batches of products, and use the same positive sample for at least 6 determinations for each batch to calculate the error rate. A.2.2.2.2
Intra-batch stability
Randomly select 1 batch of products, and use the same positive sample for at least 6 determinations to calculate the error rate. A.2.2.3
Product failure rate
The product failure rate during the shelf life shall comply with the allowable value provided by the manufacturer. A.2.2.4
Agreed error range
The agreed error range shall comply with the allowable value provided by the manufacturer.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.