title>JB/T 5332.4-1991 Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 4 Round power cables for electric submersible pumps - JB/T 5332.4-1991 - Chinese standardNet - bzxz.net
Home > JB > JB/T 5332.4-1991 Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 4 Round power cables for electric submersible pumps
JB/T 5332.4-1991 Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 4 Round power cables for electric submersible pumps

Basic Information

Standard ID: JB/T 5332.4-1991

Standard Name: Electric submersible pump cables with rated voltage up to and including 3.6/6kV Part 4 Round power cables for electric submersible pumps

Chinese Name: 额定电压3.6/6kV 及以下电动潜油泵电缆 第4部分 电动潜油泵圆形电力电缆

Standard category:Machinery Industry Standard (JB)

state:in force

Date of Release1991-06-28

Date of Implementation:1992-07-01

standard classification number

Standard Classification Number:Electrical Engineering>>Electrical Materials and General Parts>>K13 Cables and Accessories

associated standards

Procurement status:neq 1018.1019

Publication information

publishing house:Mechanical Industry Press

Publication date:1992-07-01

other information

drafter:Diao Xiangpeng, Xi Zhongbo, Wang Guozhong

Drafting unit:Shanghai Cable Research Institute of the Ministry of Machinery and Electronics Industry, Tianjin Cable Factory, etc.

Focal point unit:Shanghai Cable Research Institute of the Ministry of Machinery and Electronics Industry

Proposing unit:Shanghai Cable Research Institute of the Ministry of Machinery and Electronics Industry

Publishing department:Ministry of Machinery Industry of the People's Republic of China

Introduction to standards:

This standard specifies the product varieties, technical requirements and tests of electric submersible pump circular power cables. This standard applies to circular power cables for electric submersible (including submersible and submersible brine) pump units with rated voltages of 3.6/6KV and below. The lower end of the cable is connected to the lead cable, and the upper end is connected to the ground control cabinet. JB/T 5332.4-1991 Electric submersible pump cables with rated voltages of 3.6/6kV and below Part 4 Electric submersible pump circular power cables JB/T5332.4-1991 Standard download decompression password: www.bzxz.net

Some standard content:

ICS29.060.20
Registration number: 32059—2011
Mechanical industry standard of the People's Republic of China
JB/T5332.4—2011
Replaces JB/T5332.4—1991
Electric submersible pump cables of rating voltages up to and including 3.6/6 kVPart 4: Round power cable
Published on 2011-05-18
Implemented on 2011-08-01
Published by the Ministry of Industry and Information Technology of the People's Republic of ChinaForeword.
Normative referenced documents
Use characteristics
Model,
Technical requirements,
JB/T 5332.4-2011
JB/T5332 "Electric submersible pump cables with rated voltages of 3.6/6kV and below" is divided into four parts: Part 1: General provisions:
Part 2: Electric submersible pump lead-in cables:
Part 3: Electric submersible pump flat power cables:
Part 4: Electric submersible pump round power cables. This part is Part 4 of JB/T5332.
This part replaces JB/T5332.4-1991 "Electric submersible pump cables with rated voltages of 3.6/6kV and below".
Compared with JB/T5332.4-1991, the main changes in this part are as follows: The cable models have been modified:
-Added corresponding product specifications.
This part is proposed by the China Machinery Industry Federation. This part is under the jurisdiction of the National Technical Committee for Standardization of Electric Wires and Cables (SAC/TC213). JB/T5332.4-2011
Circular electric cable for electric submersible pumps
The responsible drafting unit for this part is Shanghai Cable Research Institute. The participating drafting units for this part are Shengli Pump Industry Submersible Cable Factory of Shengli Oilfield, Hebei Huatong Cable Manufacturing Co., Ltd., Shandong Baoshida Cable Co., Ltd., Shandong Wanda Cable Co., Ltd., Anhui Xinyate Cable Group Co., Ltd. The main drafters of this part are Qu Wenbo, Zeng Jigang, Zhao Xiaofeng, Yang Qizeng, Ba Yanqing, Ba Wen, and Xu Huasheng. The previous versions of the standards replaced by this part are: JB/T5332.4—1991.
JB/T5332.42011
Electric submersible pump cables with rated voltages of 3.6/6kV and below Part 4: Circular power cables for electric submersible pumps This part of JB/T5332 specifies the use characteristics, model specifications, technical requirements and inspection of circular power cables for electric submersible pumps with rated voltages of 3.6/6kV and below. www.bzxz.net
This part is applicable to circular power cables for electric submersible (submersible, submersible brine) pump units with rated voltages of 3.6/6kV and below. The lower end of the circular power cable is connected to the lead-in, and the upper end is connected to the ground control cabinet. Normative references
The clauses in the following documents become the clauses of this part through reference in this part of JB/T5332. For all references with an H period, all subsequent amendments (excluding errata) or revisions are not applicable to this part. However, parties to an agreement based on this part are encouraged to study whether the latest versions of these documents can be used. For any undated referenced documents, the latest version shall apply to this section. GB/T2951.11-2008 General test methods for insulation and sheath materials of electric and optical cables Part 11: General test methods for thickness and dimensions measurement Mechanical properties test (IEC60811-1-1: 2001, IDT) GB/T2952.1—2008 Cable outer sheath Part 1: General provisions GB/T3048.4—2007 GB/T3048.5—2007 GB/T3048. 8—2007
GB/T4909.2—2009
JB/T5332.1—2011
Application characteristics
Electrical performance test methods for wires and cables Part 4: Conductor DC resistance test Electrical performance test methods for wires and cables Part 5: Insulation resistance test Electrical performance test methods for wires and cables Part 8: AC voltage test (IEC60060-1:1989, bare wire test methods Part 2: Dimensional measurement of rated voltage 3.6/6kV and below) Submersible oil pump cable Part 1: General provisions
The rated voltage U/U is 1.8/3kV and 3.6/6kV. The long-term allowable operating temperature of the cable conductor and the allowable ambient temperature downhole are in accordance with the provisions of Table 2. Round cable oil and gas is suitable for occasions where the gap between the oil pipe and the casing is small. 3.3
The bending radius during laying should not be less than 500mm. 3.4
The ambient temperature for laying polypropylene insulated cables should not be lower than -20℃. Model
The model of the cable product is shown in Table 1.
Q YPNYM
QYPNYX
QYPFYM
QYPFYX
Polypropylene insulation, nylon rubber inner sheath, monel steel belt interlocking armored submersible pump round power cable, polypropylene insulation, butyl rubber inner sheath, stainless steel belt interlocking armored submersible pump iron-shaped power cable, polypropylene insulation, nylon PVC compound inner sheath, monel steel belt interlocking armored submersible pump national power cable, polypropylene insulation, nylon fluoride compound inner sheath, stainless steel belt interlocking armored submersible pump national power cable JB/T5332.42011
QYYJNYM
QYYJNYX
QYYINY
QYENYM
QYENYX
QYEEYM
QYEEYX
QYEHYM| |tt||QYEHYX
QYEQYM
QYEQYX
QYPN2Y
QYPF2Y
QYYJN2Y
QYEN2Y
QYEE2Y||tt ||QYEH2Y
Table 1 (continued)
Polypropylene insulating butadiene rubber Rubber inner expansion sheath galvanized steel tape interlocking armored submersible oil pump round power cable polyolefin insulation butyral polynitrogen composite inner sheath galvanized steel tape interlocking armored submersible oil round power cable cross-linked polyethylene Insulated nitrile rubber inner sheath Monel steel belt interlocking armored submersible pump round power cable XLPE insulated nitrile rubber inner sheath Stainless steel belt interlocking armored submersible pump round power cable XLPE insulated nitrile Rubber inner sheath galvanized steel tape interlocking armored submersible pump valve-shaped power cable EPDM insulated NBR inner sheath monel steel tape interlocking armored submersible pump round power cable EPDM insulated NBR inner sheath Stainless steel sheathed interlocking armored submersible oil pump round power cable EPDM insulation butyl rubber inner sheath galvanized steel interlocking armored submersible oil pump round power cable Inner rubber insulation, Ethylene rubber inner sheath, Monel steel belt interlocking armored submersible pump round power cable, Ethylene propylene rubber insulation, Ethylene propylene rubber inner sheath, stainless steel belt interlocking armored submersible pump round power cable, Ethylene flash rubber insulation, Ethylene flash Rubber inner sheath galvanized steel tape interlocking armored submersible oil pump type power cable ethylene flash rubber insulation chlorosulfonated polyethylene inner sheath monel steel tape interlocking armored submersible oil mushroom type power cable ethylene flash rubber insulation oxygen sulfonated Polyethylene inner sheath stainless copper belt interlocking armored submersible pump round power cable EPDM insulated sulfonated polyethylene inner sheath galvanized steel belt interlocking armored submersible pump round power cable EPDM Insulated lead inner sheath monel steel belt joint armored submersible pump round power cable EPDM rubber insulation lead inner expansion sheath stainless steel belt interlocking armored submersible pump round power cable Power cable polypropylene insulation brain rubber inner expansion sheath galvanized steel tape interlocking armor polyoxyethylene outer expansion sheath submersible pump round power cable polypropylene insulation nitrile polyoxyethylene compound inner sheath galvanized steel tape interlocking armor PVC outer sheathed submersible pump round power cable XLPE insulation NBR inner sheathed galvanized steel tape interlocking armored PVC outer sheathed submersible pump round power cable EPDM insulation Nitrile rubber Inner sheath galvanized steel tape interlocking armor PVC outer sheath submersible pump shaped power cable EPDM insulated EPDM inner rubber inner sheath galvanized steel tape interlocking armor PVC outer sheath submersible pump ring shaped Power cable with inner rubber insulation, fluorosulfonated polyethylene inner sheath, galvanized steel tape interlocking armor, PVC outer sheath, submersible oil pump round power cable. The specifications of the cable are shown in Table 2.
Rated voltage
, QYENYX, QYENY, QYEN2YQYEEYM, QYEEYX, QYEEY, QYEE2Y, QYEHYM,
QYEH2Y, || tt||QYEHY、
QYEHYX、
QYEQYM、QYEQYX
Conductor nominal
Cross-sectional area
Cable conductor long-term
Allowable working Temperature
Underground allowable
Ambient temperature
20℃ Insulation resistance
Minimum value
MQ·km
6 Technical requirements||tt ||JB/T5332.4-2011
6.1 The structure and dimensions of the cable are shown in Table 3. The conductor structure and performance shall comply with the provisions of Table 1 in JB/T5332.1-2011. Table
Conductor Standard The technical requirements for cables shall comply with the provisions of Table 4. Steel strip nominal
Project name
Structural dimensions
Conductor structure
Insulation thickness
Inner sheath thickness
Oil-resistant cushion| |tt||Armor layer
Dimensions
Electrical properties
Conductor resistance
Insulation resistance
Voltage test
Leakage current test
4h high Voltage test
Cable mechanical and physical properties
Insulation properties
Inner sheath mechanical and physical properties
Article number
Table 3 and JB/T5332.1— 20115.1.3
Table 3 and 5.2.3 in JB/T5332.12011
Table 3 and 5.3.4 in JB/T5332.1—2011 5.5 in JB/T 5332.1-2011
Table 3 and 5.6.1 in JB/T 5332.1-2011Table 3 and 5.7.1 in JB/T 5332.1-20115.7.2 in JB/T 5332.1-2011||tt ||5.7.3 in JB/T 5332.1—2011
5.7.9 in JB/T 5332.12011
5.7.4 in JB/T 5332.1—2011
5.7.6 in JB/T 5332.1—2011 2011 5.7.10
JB/T5332.1—2011 5.7.7
JB/T 5.7.8
Outer sheath nominal
Test type
With outer sheath
Test method
GB/T 4909.22009| |tt||GB/T 2951.11—2008
GB/T 2951.11-—2008
GB/T2951.11—2008
GB/T2952.1—2008||tt| |GB/T 2951.1I—2008
GB/T 3048.4-2007
GB/T Appendix E to GB/T3048.5—2007
GB/T3048.8—2007
JB/T5332.1—2011
GB/T3048.8—2007
JB/T 6.9 in 5332.1—2011
JB/T 6.11 in 5332.1—2011
JB/T5332.4—-2011
Item name
Special test||tt| |Sealing performance test of stranded conductor
High temperature and high pressure test
Armor layer bending test
Table 4 (continued)
Article number
JB/T 5332.I—2011 5.7.6
JB/T5332.1—2011 + 5.7.5
JB/T5332.1—2011 *5.7.11
The cable should be tested according to the items specified in Table 4. test. Test type
Test method
Appendix A in JB/T5332.1—2011
Appendix B in JB/T5332.1—2011
JB/T5332.1 —Appendix C of 2011 Standard of the Machinery Industry of the People's Republic of China for Rated Voltages up to and including 3.6/6kV for Electric Submersible Pumps Part 4: Electric Submersible Pumps Round power cable JB/T5332.4—2011
Published by Machinery Industry Press
No. 22, Baiwanzhuang Street, Beijing||tt ||Postal code: 100037
210mm×297mm·0.5 printing sheet·13,000 words 1st edition, 1st printing, November 2011
Price: 12.00 yuan
Book number: 15111· 10189
Website: http://www.cmpbook.comEditorial Department Tel:
(010)88379778
Direct Sales Center Tel:
(010)88379693|| tt||All covers without anti-counterfeiting labels are pirated
Copyright reserved
Infringements will be prosecutedcom editorial department phone number:
(010)88379778
Direct sales center phone number:
(01088379693
All covers without anti-counterfeiting labels are pirated
Copyright reserved
Infringements will be investigatedcom editorial department phone number:
(010)88379778
Direct sales center phone number:
(01088379693
All covers without anti-counterfeiting labels are pirated
Copyright reserved
Infringements will be investigated11-—2008
GB/T2951.11—2008
GB/T2952.1—2008
GB/T 2951.1I—2008
GB/T 3048.4- 2007
GB/T 3048.5—2007
GB/T3048.8—2007
JB/T5332.1—Appendix E in 2011
GB/T3048.8— 2007
JB/T 5332.1—2011 6.9
JB/T 5332.1—2011 6.11
JB/T5332.4—-2011
Item name
Special test
Sealing performance test of stranded conductor
High temperature and high pressure test| |tt||Armor layer bending test
Table 4 (continued)
Article number
JB/T 5332.I—2011 5.7.6
JB/T5332 .1—2011 + 5.7.5
JB/T5332.1—2011 *5.7.11
The cable should be inspected according to the items specified in Table 4. Test type
Test method
Appendix A in JB/T5332.1—2011
Appendix B in JB/T5332.1—2011
JB/T5332.1 —Appendix C of 2011 Standard of the Machinery Industry of the People's Republic of China for Rated Voltages up to and including 3.6/6kV for Electric Submersible Pumps Part 4: Electric Submersible Pumps Round power cable JB/T5332.4—2011
Published by Machinery Industry Press
No. 22, Baiwanzhuang Street, Beijing||tt ||Postal code: 100037
210mm×297mm·0.5 printing sheet·13,000 words 1st edition, 1st printing, November 2011
Price: 12.00 yuan
Book number: 15111· 10189
Website: http://www.cmpbook.comEditorial Department Tel:
(010)88379778
Direct Sales Center Tel:
(010)88379693|| tt||All covers without anti-counterfeiting labels are pirated
Copyright reserved
Infringements will be prosecuted11-—2008
GB/T2951.11—2008
GB/T2952.1—2008
GB/T 2951.1I—2008
GB/T 3048.4- 2007
GB/T 3048.5—2007
GB/T3048.8—2007
JB/T5332.1—Appendix E in 2011
GB/T3048.8— 2007
JB/T 5332.1—2011 6.9
JB/T 5332.1—2011 6.11
JB/T5332.4—-2011
Item name
Special test
Sealing performance test of stranded conductor
High temperature and high pressure test| |tt||Armor layer bending test
Table 4 (continued)
Article number
JB/T 5332.I—2011 5.7.6
JB/T5332 .1—2011 + 5.7.5
JB/T5332.1—2011 *5.7.11
The cable should be inspected according to the items specified in Table 4. Test type
Test method
Appendix A in JB/T5332.1—2011
Appendix B in JB/T5332.1—2011
JB/T5332.1 —Appendix C of 2011 Standard of the Machinery Industry of the People's Republic of China for Rated Voltages up to and including 3.6/6kV for Electric Submersible Pumps Part 4: Electric Submersible Pumps Round power cable JB/T5332.4—2011
Published by Machinery Industry Press
No. 22, Baiwanzhuang Street, Beijing||tt ||Postal code: 100037
210mm×297mm·0.5 printing sheet·13,000 words 1st edition, 1st printing, November 2011
Price: 12.00 yuan
Book number: 15111· 10189
Website: http://www.cmpbook.comEditorial Department Tel:
(010)88379778
Direct Sales Center Tel:
(010)88379693|| tt||All covers without anti-counterfeiting labels are pirated
Copyright reserved
Infringements will be prosecuted
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.