This standard specifies the product varieties, specifications, technical requirements and inspection rules for aluminum alloy contact wires. This standard applies to aluminum alloy contact wires used in electrical transportation and lifting systems such as railways, industry, mining, and urban transportation. In addition to complying with the requirements of this standard, aluminum alloy contact wires should also comply with the provisions of GBl2971.1. GB 12971.5-1991 Contact wire for electric traction Part 5: Aluminum alloy contact wire GB12971.5-1991 Standard download and decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China Contact wires for electric traction Part 5: Aluminum alloy contact wires Trolley and contact wires for electric tractionPart 5:Aluminum alloy trolley and contact wiresTheme content and scope of application This standard specifies the product varieties, specifications, technical requirements and inspection rules for aluminum alloy contact wires. GB12971.5—91 This standard is applicable to aluminum alloy contact wires used in electrical transportation and lifting systems such as railways, industry, mining, and urban transportation. In addition to complying with the requirements of this standard, aluminum alloy contact wires should also comply with The provisions of GB12971.1. 2 Model Aluminum alloy contact wire models are shown in Table 1. Table 1 Type No. CLHA 3 Specifications Aluminum alloy contact wire specifications are as specified in Table 2. nominal section mm2 130 170 200 calculation section| |tt||mm 130.1 171.1 200.5 Equivalent copper DC Resistive cross-section mm2 70 90 110 A B Table 2 Dimensions and deviations, mm||tt ||C (±2%)(±1%) (±2%) 13.48 15.40 16.64||tt| |13.48 15.40 16.64 Approved by the State Bureau of Technical Supervision on 1991-06-06 9.55 9.55 9.55 D|| tt||(%) 7.27 7.27 7. 27 Name Title Heat treated aluminum magnesium silicon rare earth alloy contact Line G E (±2%) 6.78 6.78 6.78 H||tt ||Deviation ±2° 2.670.3827° 3.970.38 4.930.38 279 27 51° 51° 51° nominal weight kg/km 350 460||tt ||540 Section Shape And ruler inch Picture 1 Implemented on 1992-03-01||tt| |4Materials 4.1 Aluminum should comply with GB1196 regulations. 4.2 Magnesium should comply with the Mg-2 regulations in GB3499. 4.3 Crystalline silicon should comply with the Si-2 regulations in GB2881. GB12971.5—91 Figure 1 4.4 Rare earths should comply with the RECe-45 regulations in GB4153. 5 Technical requirements 5.1 Dimensions and deviations The dimensions and deviations of aluminum alloy contact wires should comply with the requirements in Table 2. 5.2 Mechanical properties The mechanical properties of aluminum alloy contact wires should comply with the requirements in Table 3. 5.3 Resistivity The resistivity of aluminum alloy contact wires should comply with the requirements in Table 3. Table 3 Nominal cross-section mm 130 170 200 Breaking force, N) Not less than 33130 43310 50960 Note: 1) The gauge length during the test is 250mm. 5.4 Manufacturing length and joint elongation, %\ is not less than 4 4 4 resistance at 20℃ Rate, Qmm/m is not greater than 0.0328 0.0328 0.0328 5.4.1 The manufacturing length of the aluminum alloy contact wire should be not less than 1800m, No joints are allowed within the manufacturing length. 180° repeated twisting (once each) no breakage and cracking no breakage and cracking no breakage and cracking 5.4.2 Aluminum Alloy Contact wires are allowed to be delivered in short sections with a length of not less than 500m, and their quantity should not exceed 5% of the total delivery weight. 3 According to the agreement between the parties, aluminum alloy contact wires are allowed to be delivered in any length and short sections. 5.4.3 6 Inspection Rules Products are inspected as specified in Table 4. Serial number 1 2 3 4 5 6 7|| tt||8 Project name Dimensions and deviations Breaking force Elongation Torsion Resistivity|| tt | Key Techniques Conform to the provisions of Table 2 of Article 5.1 of this standard Conform to the provisions of Table 3 of Article 5.2 of this standard Conform to the provisions of Table 3 of Article 5.2 of this standard Conform Table 3 of Article 5.2 of this standardbzxZ.net Conforms to Table 3 of Article 5.3 of this standard Conforms to Article 4.2 of GB12971.1 Conforms to Article 5.4 of this standard||tt ||Conforms to Article 5.4 of this standard This standard is proposed by the Ministry of Mechanical and Electronics Industry of the People's Republic of China. This standard is under the jurisdiction of Shanghai Cable Research Institute. This standard was drafted by Shanghai Cable Research Institute and Wuhan Electric Wire Factory. The main drafter of this standard is Wang Xueping. Test type T,R T,s T,s T,s T,S||tt ||R R R Test method GB4909.2 GB4909.3 GB4909.3||tt| |GB4909.4 GB499.2 Normal visual inspection Measure with meter counter Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.