This standard specifies the specifications, technical requirements, test methods, inspection rules, packaging and packaging of 200-grade polyimide-fluorine composite film wrapped (single or double layer) copper rectangular wire. JB/T 6757-1993 200-grade polyimide-fluorine composite film wrapped copper rectangular wire JB/T6757-1993 Standard download decompression password: www.bzxz.net
Some standard content:
Machinery Industry Standard of the People's Republic of China JB/T 6757-1993 200 grade polyimide-Fluorine 46 composite film wrapped copper rectangular wire Published on August 21, 1993 Ministry of Machinery Industry of the People's Republic of China Implementation on October 1, 1993 Mechanical Industry Standard of the People's Republic of China 200 grade polyimide-Fluorine 46 composite film wrapped copper rectangular wire 1 Subject content and scope of application JB/T 67571993 This standard specifies the specifications, technical requirements, test methods, inspection rules, packaging and marking of 200 grade polyimide-Fluorine 46 composite film wrapped (single or double layer) copper rectangular wire. This standard applies to 200-grade polyimide-fluorine 46 composite film wrapped copper flat wire, referred to as composite film wrapped flat wire. Reference standards CB6108 GB1343 GB/T3048 GB5584 GB4074 Winding wire conductor Test method for wrapped wire Test method for electrical properties of wires and cables Electrical copper, aluminum and their alloy fan wires Test method for enameled wire Terms, codes and symbols 3.1 Terms 3.1.1 Conductor Refers to the metal part of the composite film wrapped fan wire after the insulation is removed. 3.1.2 Insulation thickness The difference between the outer dimensions of the composite film wrapped fan wire and the conductor dimensions. 3.1.3 Heat grade The heat grade is the heat resistance grade of the composite film wrapped flat wire. The minimum temperature index of 200 grade is 200, and the heat shock temperature is at least 220℃. 3.2 Code 3.2.1 Series code Film wrapped wire 3.2.2 Insulation material code Polyimide series 46 composite film 3.2.3 Conductor material code T (omitted) 3.2.4 Conductor shape code Braided conductor 3.2.5 Film wrapped layer code 3.3 Symbol D (omitted) A-Narrow side size of composite film wrapped flat wire, mm: B-Wide side size of composite film wrapped fan wire, mm; Approved by the Ministry of Machinery Industry on August 21, 1993 Implemented on October 1, 1993 Narrow side size of conductor, mm; b-Wide side size of conductor, mm; r-Corner radius of conductor, mm;Www.bzxZ.net Conductor cutting surface, mm. 3.4 Model The models of composite film wrapped flat wire are shown in Table 1. Model 3.5 Product identification method JB/T 67571993 200 grade single polyester imide-fluorine 46 composite film wrapped copper rectangular wire200 grade double polyimide-fluorine 46 composite film wrapped copper rectangular wire3.5.1 The product is indicated by model, specification, minimum insulation thickness, thermal grade and this standard number. Since there is only one thermal grade in this standard, it is omitted. 3.5.2 Example The 200-grade single-case imide-fluorine 46 composite film wrapped copper fan wire with nominal size a of 2.00mm, b of 5.00mm and minimum insulation thickness of 0.100mm is expressed as MYFB-0.100 2.00X5.00 JB6757-93 The nominal size a of 1.80mm, b of 4.00mm and minimum insulation thickness of 0.200mm The 200-grade polyimide-fluorine 46 composite film wrapped steel flat wire is represented as: MYFEB-0.200 4 Technical requirements 4.1 Material 1.80×4.00 JB6757-93 4.1.1 The pot fan wire used for composite film wrapped fan wire shall meet the requirements of GB5584.2TBR type copper flat wire. The surface of the copper nodule wire shall be smooth and shall not have burrs, scratches, copper powder, oxide layer and oil stains. 4.1.2 The insulation of composite sea film wrapped flat wire shall be polyimide-fluorine 46 composite film, and its performance shall meet the requirements of Appendix A of this standard. 4.2 Conductor 4.2.1 The nominal size and cross-sectional area of the conductor shall meet the requirements of Table 1 in GB6108.3. 4.2.2 The conductor size deviation shall comply with the provisions of Table 3 in GB6108.3. 4.2.3 The conductor corner radius shall comply with the provisions of Table 4 in GB6108.3. 4.3 Insulation 4.3.1 Single-layer composite film wrapped fan wire and double-layer composite film wrapped fan wire each have five insulation thicknesses, which are ranked from 1 to 5. 4.3.2 The minimum insulation thickness of composite film wrapped flat wire shall comply with the provisions of Table 2. 4.3.3 Maximum overall dimensions The maximum overall dimensions of composite film wrapped flat wire shall not be greater than the sum of the maximum conductor size and the maximum insulation thickness. The maximum insulation thickness is as specified in Table 3. When the maximum overall dimensions of the composite film wrapped flat wire meet the requirements, the maximum insulation thickness is allowed to exceed the value specified in Table 3. 2 Note, 1) (Bb) is not assessed. JB/T6757-1993 Minimum insulation thickness Single-layer wrapping Maximum insulation thickness Single-layer wrapping The DC resistance R2 per unit length at 20°C should not be greater than the value calculated by the following formula. Ro Pe/Snin SuianinXbni0.8584rm Where: Smin conductor minimum load area, mm; amis Conductor minimum narrow side size, mm bmi——conductor minimum wide side size, mm; Tmax conductor maximum fillet radius, mm; Pzo——pot resistivity at 20°C, take 1/58α·mm/m. 4.5 Elongation Double-layer wrapping Double-layer wrapping The elongation at break of the composite film wrapping wire should not be less than the provisions in Table 4. When preparing the test specimen, the mark shall be made on the bare conductor in a manner that does not damage the conductor properties. Narrow side (a) Nominal size 2.50 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.