title>JB/T 6213.2-1992 Flexible cables and cords for connecting motor windings Part 2 Flexible cables and cords with a maximum continuous operating conductor temperature of 70°C - JB/T 6213.2-1992 - Chinese standardNet - bzxz.net
Home > JB > JB/T 6213.2-1992 Flexible cables and cords for connecting motor windings Part 2 Flexible cables and cords with a maximum continuous operating conductor temperature of 70°C
JB/T 6213.2-1992 Flexible cables and cords for connecting motor windings Part 2 Flexible cables and cords with a maximum continuous operating conductor temperature of 70°C

Basic Information

Standard ID: JB/T 6213.2-1992

Standard Name: Flexible cables and cords for connecting motor windings Part 2 Flexible cables and cords with a maximum continuous operating conductor temperature of 70°C

Chinese Name: 电机绕组引接软电缆和软线 第2 部分 连续运行导体最高温度为70℃的软电缆和软线

Standard category:Machinery Industry Standard (JB)

state:Abolished

Date of Release1992-06-16

Date of Implementation:1993-01-01

Date of Expiration:2007-07-01

standard classification number

Standard Classification Number:Electrical Engineering>>Electrical Materials and General Parts>>K13 Cables and Accessories

associated standards

alternative situation:Replaced by JB/T 6213.2-2006

Procurement status:BS 6195 NEQ AS-40007 NEQ

Publication information

publishing house:Mechanical Industry Press

Publication date:1993-01-01

other information

Focal point unit:Shanghai Cable Research Institute

Publishing department:Shanghai Cable Research Institute

Introduction to standards:

This standard specifies the product varieties, technical requirements and inspection rules for flexible cables and cords for connecting motor windings with a maximum continuous operating conductor temperature of 70°C. This standard applies to flexible cables and cords for connecting motor windings with a maximum continuous operating conductor temperature of 70°C. In addition to meeting the requirements specified in this standard, this standard shall also meet the relevant provisions of JB 6213.1. JB/T 6213.2-1992 Flexible cables and cords for connecting motor windings Part 2 Flexible cables and cords with a maximum continuous operating conductor temperature of 70°C JB/T6213.2-1992 Standard download decompression password: www.bzxz.net

Some standard content:

Mechanical Industry Standard of the People's Republic of China
Flexible cables and cords for connecting motor windings
Part 2 Flexible cables and cords with a continuous operating conductor temperature of 70°C
Subject content and scope of application
JB6213.2-92
This standard specifies the product varieties, technical requirements and inspection rules for flexible cables and cords for connecting motor windings with a continuous operating conductor temperature of 70°C.
This standard applies to flexible cables and cords for connecting motor windings with a continuous operating conductor temperature of 70°C. In addition to meeting the requirements specified in this standard, the products shall also meet the relevant provisions of JB6213.1. Reference standards
Flexible cables and cords for connecting motor windings Part 1 3 Usage characteristics
General provisions
3.1 The AC rated voltage of the cable (wire) is 500, 1000, 3000, 6000V. 3.2 The maximum temperature of the continuous running conductor of the cable (wire) is 70°C. 3.3
The allowable bending radius of the cable (wire) during laying should not be less than 4 times the outer diameter of the cable (wire). Model
The model of the cable (wire) product is as specified in Table 1. Table
5 Specifications
Specifications are as specified in Table 2
Copper core polyvinyl chloride insulated motor winding lead-in cable (wire) Copper core nitrile polyvinyl chloride composite insulated motor winding lead-in cable (wire) Copper core rubber insulated nitrile sheathed motor winding lead-in cable (wire) Copper core rubber insulated chloroprene sheathed motor winding lead-in cable (wire) Ministry of Machinery and Electronics Industry 1992~-06-16 Approved 10
1993-01-—01 Implementation
JV, JF
JB 6213.2--92
Rated voltage
The structure of the cable (wire) is as specified in Table 3. Table
Nominal cross sectionbZxz.net
JV, JF
Nominal insulation thickness Average outer diameter upper limit
Test and inspection rules
Nominal insulation thickness
3000V6000V
Cables (wires) are tested according to the items specified in Table 4. 2.3
JXN, JXF
Nominal sheath thickness
Nominal cross section
Average outer diameter upper limit
1000v3000vj6909v
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.