This standard specifies the maximum permissible concentration of cypermethrin in the air of a workplace and the monitoring and testing methods. This standard applies to enterprises that produce and use cypermethrin. GB 16200-1996 Hygienic standard for cypermethrin in the air of a workplace GB16200-1996 Standard download decompression password: www.bzxz.net
Some standard content:
National Standard of the People's Republic of China Health standard for fenvalerate in the air of workplace Subject content and scope of application This standard specifies the maximum permissible concentration of fenvalerate in the air of workplace and the monitoring and inspection methods. This standard applies to enterprises that produce and use fenvalerate. Hygiene requirements The maximum daily average permissible concentration of fenvalerate in the air of workplace is 0.05mg/m (skin). 3 Monitoring and inspection methods The monitoring and inspection methods of this standard adopt gas chromatography, see Appendix A. 4 Supervision and implementation Health administrative departments at all levels are responsible for supervising the implementation of this standard. Approved by the State Administration of Technical Supervision on April 3, 1996 428 GB16200—1996 Implemented on September 1, 1996 A1 Principle GB 16200--- 1996 Appendix AbZxz.net Gas chromatography (Supplement) Valerythrin in the air is collected with n-hexane, separated by SE-30 column, and detected by electron capture detector. The retention time is used for qualitative analysis and the peak height is used for quantitative analysis. The detection limit of this method is 1×105μg (1ul liquid sample is injected). A2 Apparatus A2.1 Multi-hole glass plate absorption tube. A2.2 Atmospheric sampler, flow rate 0~1L/min. A2.3 Micro syringe, 1μL. A2.4 Gas chromatograph, 3Ni electron capture detector. A3 Reagents A3.1 n-hexane, analytical grade A3.2 Pure cypermethrin, 96.5% or more. A3.3 Anhydrous sodium sulfate, analytical grade, dried at 120℃ for 1h before use. A3.4 SE-30, chromatographic stationary phase, A3.5 Chromosorb WHP support, 60-80 mesh. A4 Sampling Connect two porous glass plate absorption tubes each containing 10mL n-hexane in series, and extract 10L of air at a rate of 0.5L/min. Analysis steps A5.1 Chromatographic conditions Chromatographic column: glass column with a length of 1.5m and an inner diameter of 4mm. a. b. Stationary phase: SE-3o: Chromosorb WHP support = 3:10. c. Temperature: column temperature 260℃; vaporization chamber temperature 270℃; detection chamber temperature 280℃. d, carrier gas (high purity nitrogen): 60mL/min. A5.2 Drawing of standard curve Weigh 10.0mg of pure fenvalerate, place it in a 10mL volumetric flask, dissolve it with n-hexane and dilute to the scale. Dilute it with n-hexane to 0.01, 0.02, 0.040.08μg/mL fenvalerate standard solution before use. Take 1μL of sample respectively, measure the retention time and peak height. Repeat three times for each concentration, take the average value of the peak height, plot the fenvalerate content against the peak height, and draw the standard curve. Retention time is a qualitative indicator. A5.3Sample analysis GB 162001996 Raphin Figure A1 Chromatogram of fenvalerate Time, min Wash the inner wall of the air inlet pipe three times with the absorption liquid in the absorption tube, combine the absorption liquids of the two tubes, wash the absorption tubes 2-3 times with a small amount of n-hexane respectively, and add the washing liquid to the absorption liquid to a total volume of 20mL, mix well, add 0.5g of anhydrous sodium sulfate for dehydration, take 1μL for injection, and use the retention time for qualitative analysis and the peak height for quantitative analysis. A6Calculation Where: X-the concentration of fenvalerate in the air, mg/m, C CThe concentration of fenvalerate found on the standard deduction curve, μg/mL; V. The sampling volume under standard conditions, L. Additional notes: This standard is proposed by the Ministry of Health of the People's Republic of China. This standard was drafted by Nanjing Medical University. The main drafters of this standard are Zhai Weilei and Chen Yongjin. Al) This standard is interpreted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine, the technical unit entrusted by the Ministry of Health. 130 Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.