title>GB 16200-1996 Hygienic standard for cypermethrin in workshop air - GB 16200-1996 - Chinese standardNet - bzxz.net
Home > GB > GB 16200-1996 Hygienic standard for cypermethrin in workshop air
GB 16200-1996 Hygienic standard for cypermethrin in workshop air

Basic Information

Standard ID: GB 16200-1996

Standard Name: Hygienic standard for cypermethrin in workshop air

Chinese Name: 车间空气中氰戊菊酯卫生标准

Standard category:National Standard (GB)

state:in force

Date of Release1996-04-03

Date of Implementation:1996-09-01

standard classification number

Standard ICS number:Environmental protection, health and safety>>Air quality>>13.040.30 Air quality in the workplace

Standard Classification Number:Medicine, Health, Labor Protection>>Health>>C52 Labor Hygiene

associated standards

alternative situation:Partially replaced by GBZ/T 160.78-2004

Publication information

publishing house:China Standards Press

ISBN:155066.1-12973

Publication date:2004-04-10

other information

Release date:1996-04-03

Review date:2004-10-14

Drafting unit:Nanjing Medical College of Preventive Medicine

Focal point unit:Ministry of Health

Publishing department:State Administration of Technical Supervision Ministry of Health of the People's Republic of China

competent authority:Ministry of Health

Introduction to standards:

This standard specifies the maximum permissible concentration of cypermethrin in the air of a workplace and the monitoring and testing methods. This standard applies to enterprises that produce and use cypermethrin. GB 16200-1996 Hygienic standard for cypermethrin in the air of a workplace GB16200-1996 Standard download decompression password: www.bzxz.net

Some standard content:

National Standard of the People's Republic of China
Health standard for fenvalerate in the air of workplace
Subject content and scope of application
This standard specifies the maximum permissible concentration of fenvalerate in the air of workplace and the monitoring and inspection methods. This standard applies to enterprises that produce and use fenvalerate. Hygiene requirements
The maximum daily average permissible concentration of fenvalerate in the air of workplace is 0.05mg/m (skin). 3 Monitoring and inspection methods
The monitoring and inspection methods of this standard adopt gas chromatography, see Appendix A. 4 Supervision and implementation
Health administrative departments at all levels are responsible for supervising the implementation of this standard. Approved by the State Administration of Technical Supervision on April 3, 1996 428
GB16200—1996
Implemented on September 1, 1996
A1 Principle
GB 16200--- 1996
Appendix AbZxz.net
Gas chromatography
(Supplement)
Valerythrin in the air is collected with n-hexane, separated by SE-30 column, and detected by electron capture detector. The retention time is used for qualitative analysis and the peak height is used for quantitative analysis.
The detection limit of this method is 1×105μg (1ul liquid sample is injected). A2 Apparatus
A2.1 Multi-hole glass plate absorption tube.
A2.2 Atmospheric sampler, flow rate 0~1L/min. A2.3 Micro syringe, 1μL.
A2.4 Gas chromatograph, 3Ni electron capture detector. A3 Reagents
A3.1 n-hexane, analytical grade
A3.2 Pure cypermethrin, 96.5% or more. A3.3 Anhydrous sodium sulfate, analytical grade, dried at 120℃ for 1h before use. A3.4 SE-30, chromatographic stationary phase,
A3.5 Chromosorb WHP support, 60-80 mesh. A4 Sampling
Connect two porous glass plate absorption tubes each containing 10mL n-hexane in series, and extract 10L of air at a rate of 0.5L/min. Analysis steps
A5.1 Chromatographic conditions
Chromatographic column: glass column with a length of 1.5m and an inner diameter of 4mm. a.
b. Stationary phase: SE-3o: Chromosorb WHP support = 3:10. c. Temperature: column temperature 260℃;
vaporization chamber temperature 270℃;
detection chamber temperature 280℃.
d, carrier gas (high purity nitrogen): 60mL/min. A5.2 Drawing of standard curve
Weigh 10.0mg of pure fenvalerate, place it in a 10mL volumetric flask, dissolve it with n-hexane and dilute to the scale. Dilute it with n-hexane to 0.01, 0.02, 0.040.08μg/mL fenvalerate standard solution before use. Take 1μL of sample respectively, measure the retention time and peak height. Repeat three times for each concentration, take the average value of the peak height, plot the fenvalerate content against the peak height, and draw the standard curve. Retention time is a qualitative indicator.
A5.3Sample analysis
GB 162001996
Raphin
Figure A1 Chromatogram of fenvalerate
Time, min
Wash the inner wall of the air inlet pipe three times with the absorption liquid in the absorption tube, combine the absorption liquids of the two tubes, wash the absorption tubes 2-3 times with a small amount of n-hexane respectively, and add the washing liquid to the absorption liquid to a total volume of 20mL, mix well, add 0.5g of anhydrous sodium sulfate for dehydration, take 1μL for injection, and use the retention time for qualitative analysis and the peak height for quantitative analysis.
A6Calculation
Where: X-the concentration of fenvalerate in the air, mg/m, C
CThe concentration of fenvalerate found on the standard deduction curve, μg/mL; V. The sampling volume under standard conditions, L. Additional notes:
This standard is proposed by the Ministry of Health of the People's Republic of China. This standard was drafted by Nanjing Medical University. The main drafters of this standard are Zhai Weilei and Chen Yongjin. Al)
This standard is interpreted by the Institute of Labor Hygiene and Occupational Diseases, Chinese Academy of Preventive Medicine, the technical unit entrusted by the Ministry of Health. 130
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.