title>GB 19079.4-2005 Opening conditions and technical requirements for sports venues Part 4: Rock climbing venues - GB 19079.4-2005 - Chinese standardNet - bzxz.net
Home > GB > GB 19079.4-2005 Opening conditions and technical requirements for sports venues Part 4: Rock climbing venues
GB 19079.4-2005 Opening conditions and technical requirements for sports venues Part 4: Rock climbing venues

Basic Information

Standard ID: GB 19079.4-2005

Standard Name: Opening conditions and technical requirements for sports venues Part 4: Rock climbing venues

Chinese Name: 体育场所开放条件与技术要求 第4部分:攀岩场所

Standard category:National Standard (GB)

state:in force

Date of Release2005-01-24

Date of Implementation:2005-06-01

standard classification number

Standard ICS number:Household and commercial equipment, recreation, sports >> 97.220 Sports equipment and facilities

Standard Classification Number:Light Industry, Culture and Living Goods>>Culture, Education, Sports and Entertainment Goods>>Y55 Sports Facilities and Equipment

associated standards

Publication information

publishing house:China Standards Press

ISBN:155066.1-22402

Plan number:20032357-Q-451

Publication date:2005-02-17

other information

Release date:2005-01-24

drafter:Hao Guangan, Xue Yun, Chen Xueling, Liu Daqing, Li Zhixin, Yang Shitao, Wang Liquan, Shi Chunjian, Li Zhi

Drafting unit:Mountaineering Management Center of the State Sports General Administration, Peking University

Focal point unit:Sports Economics Department of the State Sports General Administration

Proposing unit:State Sports General Administration

Publishing department:General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China Standardization Administration of China

competent authority:State Sports General Administration

Introduction to standards:

This part of GB 19079 stipulates the basic conditions and basic technical requirements for the opening of rock climbing venues. This part applies to all types of rock climbing venues open to the public. GB 19079.4-2005 Opening conditions and technical requirements for sports venues Part 4: Rock climbing venues GB19079.4-2005 Standard download decompression password: www.bzxz.net

Some standard content:

ICS97.220
National Standard of the People's Republic of China
GB19079.4—2005
Operation conditions and technical requirements for gymnasium and playgroundPart 4: Rock elimbing place
2005-01-24Promulgated
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of ChinaStandardization Administration of the People's Republic of ChinaLast meeting
2005-06-01Implementation
GB19079 Operation conditions and technical requirements for gymnasium and playgroundPart 4: Rock elimbing place ;
-Part 6: Skiing places;
Part 7: Skating places:
Part 8: Shooting places:
Part 9: Archery places:
-Part 10: Diving places;
Part 11: Rafting places:
Part 12: Paragliding places;
--Part 13: Hot air balloon places:
Part 14: Powered paragliding places;
This part is Part 4 of GB190?9. All the contents of this part are mandatory. This part is proposed by the State Sports General Administration.
This part is under the jurisdiction of the Sports Economics Department of the State Sports General Administration and is responsible for interpretation. Drafting units of this part: Mountaineering Sports Management Center of the State Sports General Administration and Peking University. GB 19079, 4—2005bZxz.net
The main drafters of this part are Hao Guangan, Xue Yun, Chen Xueling, Liu Daqing, Li Zhixin, Yang Shitao, Qi Liquan, Shi Chunjian and Li Zhi. 1 Scope
Opening conditions and technical requirements for sports venues
Part 4: Rock climbing venues
GB19079.4—2005
(This part of GB19079 specifies the basic conditions and basic technical requirements for the opening of climbing venues. This part is applicable to all kinds of climbing venues open to the public. 2 Normative references
The clauses in the following documents become the clauses of this standard through the reference of this standard. For the applicable documents of the period indicated, all amendments (excluding errata) or revisions thereto shall not apply to this standard. However, the parties to the agreement reached under this standard are encouraged to study whether the latest versions of these documents can be used. The latest version of the dated referenced documents shall apply to this standard. GB6566 Standard for radionuclides of building materials GB9668 Hygiene standard for gymnasiums GB/T17093 Total number of bacteria in indoor air GB/18883-2002 Standard for indoor air quality CR/T100C? 1 Symbols for signs Part 1: General symbols 3 Terms and definitions Rock climbing place Rock climbing place A place where people can carry out rock climbing (climbing) sports training, competition, fitness and leisure activities. It includes: artificial rock climbing places and natural rock climbing places. Artificial rock wall Climbingruck is a kind of artificial rock wall constructed indoors or outdoors for rock climbing. 3.3 Rock climbing technical instructor refers to the person who teaches climbing sports theory and skills. 4 Qualification of practitioners Rock climbing technical instructors and others should hold relevant national qualifications for the hot industry. 5 Site, facilities and equipment conditions 5.1 Artificial rock wall 5.1.1 The maximum force of the upper anchor point shall not be less than 816.33kg square, 5.1.2 The maximum force of the protective hanging piece shall not be less than 816.33kg force. 5.1.3 The static pressure resistance of the rock plate shall not be less than 108.16kg force. 5. 1. 4 The maximum impact resistance of the rock plate shall not be less than 612. 24 kg force, 5. t.5 The maximum tensile resistance of the fulcrum hole shall not be less than 306. 12 kg force. 19079.4-2005
5.2 Natural rock trap
5.2.1 The maximum force of the upper pin point shall not be less than 816.33 kg force, 5.2.2 The maximum force of the protection hanging piece shall not be less than 816. 33 kg force, 5.3 Protection equipment
5.3. 1 The diameter of the protection rope shall not be less than 10 mm, and the tensile strength shall not be less than 700 kg force. The ear adopts a single rope protection state: 5.3.2 The lateral tensile strength of the threaded safety iron lock shall not be less than 918.33 kg force, and the longitudinal tensile strength shall not be less than 2241.90 kg force. 5.3.3 The lateral tensile strength of the safety iron lock shall not be less than 714.29 kg force, and the longitudinal tensile strength shall not be less than 2244.90 kg force. 5.3.4 The tensile strength of the brake (descender) shall not be less than 2448.98 kg force. 5.3.5 The tensile strength of the safety belt shall not be less than 1 734.69 kg. 5.4 Auxiliary equipment
5.4.1 There shall be clear and eye-catching warning signs and safety protection facilities for dangerous areas. 5.4.2 There shall be men's and women's changing rooms with facilities for storing clothes. 5.4.3 The rock climbing site in the kiln shall have emergency evacuation passages. 5.4.4 The public signs and signs of the rock climbing site shall comply with the requirements of GB/T10001.1. 6 Sanitation and environmental management requirements
Artificial rock walls shall comply with the requirements of GB6566. 6.2 The environmental sanitation of the rock climbing site shall comply with the requirements of GB9668. 6.3 The indoor air of the rock climbing site shall comply with the requirements of GB/T17093 and (:B/T18883-2002. 7 Safety Assurance
7.1 There shall be "Instructions for Rock Climbers" and safety warnings at the wake-up position. 7.2 During the opening period, each rock climbing trail in use shall be equipped with a rock climbing technical instructor. 7.3 There shall be a sound safety inspection system for facilities and equipment. Damaged equipment shall be replaced in a timely manner. 7.4 First aid medicines and equipment shall be placed in a conspicuous location for use. 7.5 There shall be clear signs for all types of personnel to take up their posts.
7.6 There shall be a sound security protection, safety education and care, equipment maintenance system and personnel service post responsibility system.
Tip: This standard content only shows part of the intercepted content of the complete standard. If you need the complete standard, please go to the top to download the complete standard document for free.